HomeMy WebLinkAbout5741-2CITRUS AVENUE
4
U
Lan
WATER EFFICIENT LANDSCAPE MAINTENANCE WEEKLY SCHEDULE:
I. MONITORING AND ADJUSTING OF 'SMART' CONTROLLERS; RAIN
SENSORS AND/ OR WEATHER EQUIPMENT WHERE APPLICABLE,
2. MONITOR, REPAIR AND REPLACE IRRIGATION EQUIPMENT SUCH AS
LEAKING AND CLOGGED HEADS OR VALVES, BROKEN PIPING, ETC.
3, CALIBRATING IRRIGATION. APPLICATION EQUIPMENT TO PROVIDE
MAXIMUM EFFICIENCY.
4. REPLACE AND MAINTAIN MINIMUM LEVELS OF MULCH IN ALL
SHRUB BEDS.
5, CONSISTENTLY PRUNE ALL SHRUBS AND VINES TO MAINTAIN
CLEARANCE AROUND UTILITY EQUIPMENT AND PROVIDE OPTIMUM
WATER APPLICATION RATES.
6. REPAIR ALL IRRIGATION EQUIPMENT WITH ORIGINALLY INSTALLED PARTS,
9. REPLACE ALL PLANT MATERIALS WITH IDENTICAL/EQUAL WATER USE
REQUIREMENT SPECIES.
8. ADJUST CONTROLLER TIMING BASED UPON SEASONAL WEATHER ANP
SOIL CONDITIONS.
AREA MAPPED
NO SCALE
El
El
W
0
Q11.7 y9.7
III 1 zBan 190
Z41 r 4
J
❑ 1
QI
1
CITRUS AVENUE
CITRUS AVENUE
LOT "A"
70
71
CITY OF FONTANA NOTE:
IRRIGATION CROSSINGS UNDER ANY HARD SURFACE
SHALL BE MARKED WITH AN "IR" STENCIL ON WET
CONCRETE ON BOTHE SIDES OF THE STREET/CROSSING
WORST CONDITION PRESSURE LOSS CALC.
VALVE STATION NO. "A-18" (15 GPM)
GENERAL IRRIGATION NOTES:
WATER METER -------------------
1.2
R.P. BACKFLOW ------------------
11.5
MASTER VALVE/F.S.--------------
1.1
FERT. INJECTOR ------------------
1.5
BALL VALVES -------------------
1.5
REMOTE CONTROL VALVE -------
3.5
MAINLINE (1,000') ----------------
T7
LATERAL LINE -------------------
3.2
FITTINGS (20% LOSS) -------------
2.0
ELEVATION (132') -----------------<511>
TOTAL SYSTEM LOSSES ----------
2.49
PRESSURE REQUIRED 6 HEAD----
30.0
TOTAL PRE55URE REQUIRED------
5149
AVAILABLE STATIC PRESSURE----
h5.0
RESIDUAL PRESSURE (13%) --------
1.51
1" DOMESTIC WATER METER (BY OTHERS) / P.O.C. 'A"
1.5" R.P. BACKFLOW, 1.5" M VALVE 4 1.5' FLOW SENSOR
4 FERTILIZER INJECTOR (LINE SIZE)
ELEVATION: 15812'
ASSUMED STATIC PRESSURE 60-165 PSI
MAX. IDEMAND: 18.0 G.P.M. / MIN. DEMAND:5.0 GPM
CITRUS AVENUE
///////////e///WOMP=0��./////////�
WATER CALCULATIONS for SITE
(Includes sheets L-2, L-3)
REFERENCE ETO: 55.6
ZONE NO./DESCRIPTION
GENERAL IRRIGATION NOTES:
Plant
REGULAR LANDSCAPE AREAS: ( ) r
Irrigation Irrigation ETAF
Method Efflctency (PPAE)
Landscape
Area (Sq, Ft.) (ETAF x Area)
ETILU
1 - SHRUBS - MEDIUM 0.4
Drip 0.81 032
21,135 619(03
233,134
2 - SHRUBS - LOW 02
Drip 0.81 0.16
15,990 2,523
Gro V12
3 - TREES - BUBBLERS 0.4
Bubbler 081 0.32
490 159
5,412
direction. Install schedule 40 PVC sleeves under all paving. t
3. All piping between the point of connection and backflow preventer and/or vacuum breakers shall I
be of materials and installation methods required by the local codes.
4. Irrigation contractor must stop all 'low head" drainage by installing appropriate in line check '
TOTALS
39,395 I 9,443 I
325,518
MAXIMUM ALLOWED WATER ALLOWANCE(MAWA)
908,953
6. Irrigation contractor shall flush all lines and adjust all valves for maximum performance.
7. Do not willfully install the system as designed when it is obvious in the field that unknown obs-
tructions or grade differences exist that were not known during designing. Such conditions shall
Regular Total Landscape Areas:
TOTAL ETAF x Area = 9,443
TOTAL AREA = 39,395 SOFT.
AVERAGE ETAF 0.25
6/11/2018
- &�o
5� SIGNED: DATE:
9
H
U
D e �A�
,may DIAL TWO WORKING
m BEFORE DAYS BEFORE
yF YOU DIG YOU DIG
Q' TOLL FREE 1-800-227-2600
CG A PUBLIC SERVICE BY
CVr.. UNDERGROUND SERVICE ALERT
i
CITY OF FONTANA NOTES:
1. RECIRCULATING WATER SYSTEMS SHALL BE USED FOR WATER FEATURES.
2. PRESSURE REGULATING DEVICES ARE REQUIRED IF WATER PRESS IS BELOW
OR EXCEEDS THE RECOMMENDED PRESSURE OF THE SPECIFIED IRRIGATION
DEVICES.
3. CHECK VALVES OR ANTI -DRAIN VALVES ARE REQUIRED ON ALL SPRINKLER
HEADS WHERE LOW POINT DRAINAGE COULD OCCUR.
4. A DIAGRAM OF THE IRRIGATION PLAN SHOWING HYDRO -ZONES SHALL BE
KEPT WITH THE IRRIGATION CONTROLLER FOR SUBSEQUENT MANAGEMENT
PURPOSES.
S. AN IRRIGATION AUDIT REPORT SHALL BE COMPLETED PER SECTION 28-106
WITHIN THE CITY OF FONTANA LANDSCAPE ORDINANCE #1734 AT THE SAME
TIME OF FINAL INSPECTION.
CITY OF FONTANA NOTE:
ALL IRRIGATION SYSTEM DESIGNS THAT WILL BE MAINTAINED BY
THE CITY OF FONTANA SHALL BE INSTALLED AS A RECYCLED
WATER IRRIGATION SYSTEM FOR THE CURRENT AND FUTURE USE
OF RECYCLED WATER AND SHALL BE DESIGNED AND OPERATED IN
ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE LAWS.
FRANK
RADMACHER
ASSOCIATES, INC.
Landscape Architects
PHONE (714) 832-1774 FAX (714) 832-5721
14841 Yorba Street, Suite 204 - Tustin, CA 92780
EMAIL: FRA1110@FRAINC.NET
1
•
CITY OF FONTANA NOTE: DRIP INDICATORS
CONTRACTOR SHALL INSTALL TWO (2) RAIN BIRD DRIP
INDICATORS PER VALVE. ONE AFTER THE VALVE AND
ONE AT THE END OF THE MANIFOLD SYSTEM. RAIN
BIRD INDICATIOR MODEL #OPERID ITEM #X17500.
rr.
CITY OF FONTANA NOTE:
AT THE TIME OF FINAL INSPECTION, THE PERMIT APPLICANT MUST
PROVIDE THE OWNER OF THE PROPERTY WITH A CERTIFICATE OF
COMPLETION, CERTIFICATE OF INSTALLATION, AND AN IRRIGATION
SCHEDULE OF LANDSCAPE AND MAINTENANCE
RE -i.
NNDSCApF
�p CAL\� r
REOISION DESCRIPTION
2' BCH 40 SLEEVE
L - - - - -
-
F -- - - -
- ---------
- - - - - -1- - - - - - - - - -
O
W
1 J
LINE Oil SIO CT _ A5 ( El1„ 1 O
9.5 - - i J
_ 1950 - - W
_ t m
- -.�� .T T. T � �►' T T-!� � �. �! T. -G- TW �- T� ter' T T •� �. �F V/
01
..'.'%
IA4
18.0
180
PENNSYLVANIA AVE.
ELECTRICAL POINT OF CONNECTION 'A'
24 STATION PEDESTAL CONTROLLER FOR C.F.D.
LINE 00 SID CIT IRRIGATION. DEVELOPER SHALL PROVIDE
110-120 VAC ELECTRIC TO THIS LOCATION.
LOT "B"
ZONE NO./DESCRIPTION
GENERAL IRRIGATION NOTES:
HYpROZONE *I
1. This sprinkler system design is based on the minimum operating pressure shown on the irrigation
drawings at each point of connection. The irrigation contractor shall verify water pressure on the W
SHRUIBS 4 TREES / DRIP
site prior to construction. Report any difference between the water pressure indicated on the Z
HYDROZONE 02
drawings and the actual pressure reading at the irrigation point of connection to the Landscape 1 J
SHRUBS 4 TREES / DRIP
Architect and City Representative.
HYDROZONE 03
2. The Developer shall provide required line voltage to the controller location(s). Irrigation ❑
V
TREES / BUBBLERS
contractor shall make final hook-up. Install No. 14 OF minimum direct burial irrigation wire t
(black pilot, white common). Use epoxy connectors and bury wire with main line, bundled and ( Q
feet. Form
taped together every ten expansion coils at each remote control valve and change of
direction. Install schedule 40 PVC sleeves under all paving. t
3. All piping between the point of connection and backflow preventer and/or vacuum breakers shall I
be of materials and installation methods required by the local codes.
4. Irrigation contractor must stop all 'low head" drainage by installing appropriate in line check '
valves as necessary.
5. This design is diagrammatic. Equipment shown in paved areas is for design clarification only;
actual equipment is to be installed within planted areas wherever possible.
6. Irrigation contractor shall flush all lines and adjust all valves for maximum performance.
7. Do not willfully install the system as designed when it is obvious in the field that unknown obs-
tructions or grade differences exist that were not known during designing. Such conditions shall
be brought to the attention of the Landscape Architect and Owner or Developer's representative;
otherwise the irrigation contractor must assume full responsibility for any and all necessary revisions.
8. Install all components as called for by the City of Fontana irrigation guidelines and detail drawings.
9. Final location of automatic controllers, rain sensors, and valves shall be approved by the City
representative prior to installation. Valve locations are shown for design clarity only.
10. It is the responsibility of the irrigation contractor to familiarize himself with all grade differences,
locations of walls, walks, mow curbs, and turf locations edges, etc.. He shall coordinate his work
with the general contractor and other sub -contractors for the location and installation of pipe sleeves
through walls, under roadways, paving, structures, etc..
It. Contractor shall familiarize himself with Rain Bird dripline installation details and specifications prior
to start of work. Contact Rain Bird representative Greg Steele at (949) 632-8627 for more information
on proper slope layout to prevent low head drainage. Refer to Rain Bird details for proper location of all
be
equipment requried to installed for a complete system layout. Not all equipment is shown on plans.
12. Irrigation contractor shall be responsible for installing Sch. 40 sleeves for all lateral and pressure main-
line under pavement. Sleeves shall be of sufficient size to be twice that of the irrigation line piping.
13. Sleeving for all pressure/non-pressure lines and wires under hardscape shall be installed pprior to paving
Whe irriggation contractor. Sleeve all piping and wires under pavement a minimum of 24" deep with
C SCH. 40 pipe sized two times the pipe diameter or wire bundle, larger if necessary. Extend sleeves
24" beyond pavement. Sleeves may not be shown under walks but shall be installed as noted above.
14. Contractor shall coordinate with the City of Fontana for all irrigation system components and requirements 1
for CFD areas. Controller model number, enclosure and options shall be per current City of Fontana I
standard drawings.
- 1
I
F-
1" O❑S►C7❑T - 1" CONTINUE '
"A-11 "SYSTEM
W
❑
U)
-Al
W
U)
A9
I,, END "A-10"
21.0 LOT "C" SYSTEM
210 9 IRRIGATION LEGEND 11
-ENTRY
MONUMENT SIGN CYMBOI MANUFACTuRFR/MODFI NO-/DF3CRIPnoN DETAIL REF.
RAIN BIRD MODEL NO. XFS DRIPLINE. BURIED 4" DEEP BELOW GRADE (6 GPH 0 18"). INSTALL IN ROWS D-H/L-8
18"-24" ON CENTER, DEPENDING UPON PLANT MATERIAL SPACING. START 2" AWAY FROM HARDSCAPE.
r e INSTALL WITH ALL RAIN BIRD COMPRESSION FITTINGS AND COMPONENTS. INSTALL FLUSH VALVES AND AIR
RELIEF VALVE FOR EACH SYSTEM -TYPICAL. REFER TO RAIN BIRD DETAILS.
F_
1 RAIN BIRD XFCV DRIPLINE w/ BUILT-IN CHECK VALVE. INSTALL ON GRADE FOR SLOPES. (.6 GPH 0 24") B/L -7
MODEL #XFCV-06-24-100. INSTALL IN ROWS 24' ON CENTER, START 2" AWAY FROM HARDSCAPE.
S INSTALL WITH RAIN BIRD XF INSERT FITTINGS AND COMPONENTS. INSTALL FLUSH VALVES AND AIR RELIEF FOR
j EACH SYSTEM -TYPICAL. SECURE DRIPLINE TO GRADE WITH RAIN BIRD TDS-050 BEND GALV. STAKES.
L� (MIN. 6' ON CENTER SPACING). REFER TO RAIN BIRD DETAILS
0RAIN BIRD XFCV DOUBLE DRIPLINE TREE RING CA -7
• DEEP WATERING TREE BUBBLERS: RAIN BIRD RWS-M-8-1402 (0.5 GPM) /2 PER TREE EQUALLY SPACED AA -7
p REDUCED PRESSURE BACKFLOW PREVENTER- WILKINS #375 (PLASTIC) WITH WILKINS #600 XL-HLR-G. 5007A-6
(SAME SIZE AS MAINLINE). INSTALL IN A "GUARDSHACK" LOCKING - HINDGED ENCLOSURE (GREEN).
RAIN BIRD #PESB-R-PRSD PRESSURE REDUCING/MASTER VALVE - LINE SIZE. SET DISCHARGE PRESSURE 501O-6
PRESSURE AS REQUIRED. VERIFY EXISTING PRESSURE BEFORE INSTALLING. /
® DATA INDUSTRIAL FLOW SENSOR MODEL #228PV3005 - INSTALL SAME SIZE AS MAINLINE. 501OA-6
EZ -FLOW FERTILIZER INJECTOR MODEL #EZ003-CX. LINE SIZE. INSTALL PER MANUFACTURER'S & CITY XA-7
SPECIFICATIONS.
►� NIBCO T-580 BRASS BALL VALVE OR EQUAL- LINE SIZE. INSTALL IN ROUND BOX. 5019A-6
3/4" RAINBIRD #33DLRC QUICK COUPLING VALVE w/RUBBER COVER IN BOX MARKED "QC" 5021A-9
® RAIN BIRD IN-LINE DRIP ZONE KIT #XCZ-100-PRB-COM FOR FLOWS 3-20 GPM. INSTALL IN RECT. BOX 5038A-9
RAIN BIRD GB BRASS ELECTRIC CONTROL VALVE. INSTALL IN RECTANGULAR BOX. SIZES NOTED. 5011A-6
TORO SENTINAL CONTROLLER w/WIRELESS BOARD. MODEL #SBYPSS5U (8 OR 24 STATION) SEE PLAN -MOUNTED 5005,5006A-6
® IN AN APPROVED STAINLESS STEEL NEMA RATED EDISON BOX ENCLOSURE. REFER TO DETAILS FOR ALL CITY
REQUIREMENTS AND ACCESORIES. CONTACT DARYL GREEN AT GREEN PRODUCT SALES WHEN ORDERING
AND TO SCHEDULE INSPECTION FOR CERTIFICATION. (949) 584-7311. GPS10CEARTHLINK.NET.
(INSTALL SENTINAL ANTENNA ON THE TOP OF THE RAIN BUCKET POLE AND ELIMINATE RAIN BUCKET.)
PENNSYLVANIA AVE. HAND HELD IRRIGATION RADIO CONTROLLER SHALL BE FULLY FUNCTIONAL AND TURNED OVER TO THE CITY OF
FONTANA AT THE TIME OF FINAL ACCEPTANCE.
DOMESTIC WATER METER PER FONTANA WATER (EXISTING). SIZES NOTED.
PRESSURE MAIN LINE PIPING. USE PVC SCH. 40 / BURY MINIMUM 18" DEEP. SIZES NOTED. 5016A-6
NON -PRESSURE LATERAL LINE PIPING -USE SCH. 40 PVC. BURY MINIMUM 12" DEEP. 5016A-6
:.:............:... SCH. 40 PVC IRRIGATION SLEEVE UNDER PAVEMENT / SIZE 2 X PIPE OR WIRE BUNDLE 5018A-6
CITY OF FONTANA NOTE; PRESSURE REGULATION
PRESSURE REGULATORS SHALL BE INSTALLED ON THE
IRRIGATION SYSTEM ENSURING THAT DYNAMIC
PRESSURE OF THE SYSTEM IS WITHIN THE
MANUFACTURER'S RECOMMENDED PRESSURE RANGE.
DATE EN7R. CITY DATE
SGOULD CONSTRUCTION OD TOE REQUIRED
IMPROCEMENTS NOT COMMENCE C ITAN TO O
YEARS OO TOE DATE OGAPPROCAL SOOO N
❑EREON AND CARRIED OORTO IN A DILIGENT
MANNER, TOE CITY ENGINEER MAY REQUIRE
RECISIONS TO TOE PLANS TO BRING TCEM INTO
CONCORMANCE C ITC CONDITIONS AND
STANDARDS IN EOOECT.
CONTROLLER STATION
VALVE SIZE
FLOW IN G.PM,
HYDROZONE
AREA (SQ. FT.)
�4YDROZONE LEG ND
ZONE NO./DESCRIPTION
WUCOLS
HYpROZONE *I
LOW -MEDIUM
SHRUIBS 4 TREES / DRIP
HYDROZONE 02
LOW
SHRUBS 4 TREES / DRIP
HYDROZONE 03
MEDIUM -LOW
TREES / BUBBLERS
BASIS OF BEARINGS:
I HL BASIS OF BEARINGS WAS I AKEN FROM THE CENTERLINE OF
CITRUS AVENUE AS SHOWN ON TRACT 16540, M.B. 299/13-15.
BEING: N00°16'44"W
BENCHMARK: DRAT N BY:
K NO. 8-17 � "1 GI I
BRASS CAP IN CONCRETE S.C.E. TOWER LEG. 343' N/0
HIGHLAND AVENUE, 0.2 MI W/O SAN SEVAINE ROAD, IN SOUTH
CONCRETE BASE OF S.C.E. TOWER 19.5; 2.65 MI. WEST C-iECKED BY:
ALONG HIGHLAND AVENUE FROM SIERRA AVENUE
EL=1428.6199
1
CITY O❑ ❑ONTANA, CALI❑ORNIA
IRRI❑ATION PLAN
CITRUS 105
TR. 18981 FONTANA, CALIFORNIA
APPROCED BY: r
1"1_20❑
TE:
81212018
A171 IN[- NO.: 2