HomeMy WebLinkAbout5741-2CITRUS AVENUE 4 U Lan WATER EFFICIENT LANDSCAPE MAINTENANCE WEEKLY SCHEDULE: I. MONITORING AND ADJUSTING OF 'SMART' CONTROLLERS; RAIN SENSORS AND/ OR WEATHER EQUIPMENT WHERE APPLICABLE, 2. MONITOR, REPAIR AND REPLACE IRRIGATION EQUIPMENT SUCH AS LEAKING AND CLOGGED HEADS OR VALVES, BROKEN PIPING, ETC. 3, CALIBRATING IRRIGATION. APPLICATION EQUIPMENT TO PROVIDE MAXIMUM EFFICIENCY. 4. REPLACE AND MAINTAIN MINIMUM LEVELS OF MULCH IN ALL SHRUB BEDS. 5, CONSISTENTLY PRUNE ALL SHRUBS AND VINES TO MAINTAIN CLEARANCE AROUND UTILITY EQUIPMENT AND PROVIDE OPTIMUM WATER APPLICATION RATES. 6. REPAIR ALL IRRIGATION EQUIPMENT WITH ORIGINALLY INSTALLED PARTS, 9. REPLACE ALL PLANT MATERIALS WITH IDENTICAL/EQUAL WATER USE REQUIREMENT SPECIES. 8. ADJUST CONTROLLER TIMING BASED UPON SEASONAL WEATHER ANP SOIL CONDITIONS. AREA MAPPED NO SCALE El El W 0 Q11.7 y9.7 III 1 zBan 190 Z41 r 4 J ❑ 1 QI 1 CITRUS AVENUE CITRUS AVENUE LOT "A" 70 71 CITY OF FONTANA NOTE: IRRIGATION CROSSINGS UNDER ANY HARD SURFACE SHALL BE MARKED WITH AN "IR" STENCIL ON WET CONCRETE ON BOTHE SIDES OF THE STREET/CROSSING WORST CONDITION PRESSURE LOSS CALC. VALVE STATION NO. "A-18" (15 GPM) GENERAL IRRIGATION NOTES: WATER METER ------------------- 1.2 R.P. BACKFLOW ------------------ 11.5 MASTER VALVE/F.S.-------------- 1.1 FERT. INJECTOR ------------------ 1.5 BALL VALVES ------------------- 1.5 REMOTE CONTROL VALVE ------- 3.5 MAINLINE (1,000') ---------------- T7 LATERAL LINE ------------------- 3.2 FITTINGS (20% LOSS) ------------- 2.0 ELEVATION (132') -----------------<511> TOTAL SYSTEM LOSSES ---------- 2.49 PRESSURE REQUIRED 6 HEAD---- 30.0 TOTAL PRE55URE REQUIRED------ 5149 AVAILABLE STATIC PRESSURE---- h5.0 RESIDUAL PRESSURE (13%) -------- 1.51 1" DOMESTIC WATER METER (BY OTHERS) / P.O.C. 'A" 1.5" R.P. BACKFLOW, 1.5" M VALVE 4 1.5' FLOW SENSOR 4 FERTILIZER INJECTOR (LINE SIZE) ELEVATION: 15812' ASSUMED STATIC PRESSURE 60-165 PSI MAX. IDEMAND: 18.0 G.P.M. / MIN. DEMAND:5.0 GPM CITRUS AVENUE ///////////e///WOMP=0��./////////� WATER CALCULATIONS for SITE (Includes sheets L-2, L-3) REFERENCE ETO: 55.6 ZONE NO./DESCRIPTION GENERAL IRRIGATION NOTES: Plant REGULAR LANDSCAPE AREAS: ( ) r Irrigation Irrigation ETAF Method Efflctency (PPAE) Landscape Area (Sq, Ft.) (ETAF x Area) ETILU 1 - SHRUBS - MEDIUM 0.4 Drip 0.81 032 21,135 619(03 233,134 2 - SHRUBS - LOW 02 Drip 0.81 0.16 15,990 2,523 Gro V12 3 - TREES - BUBBLERS 0.4 Bubbler 081 0.32 490 159 5,412 direction. Install schedule 40 PVC sleeves under all paving. t 3. All piping between the point of connection and backflow preventer and/or vacuum breakers shall I be of materials and installation methods required by the local codes. 4. Irrigation contractor must stop all 'low head" drainage by installing appropriate in line check ' TOTALS 39,395 I 9,443 I 325,518 MAXIMUM ALLOWED WATER ALLOWANCE(MAWA) 908,953 6. Irrigation contractor shall flush all lines and adjust all valves for maximum performance. 7. Do not willfully install the system as designed when it is obvious in the field that unknown obs- tructions or grade differences exist that were not known during designing. Such conditions shall Regular Total Landscape Areas: TOTAL ETAF x Area = 9,443 TOTAL AREA = 39,395 SOFT. AVERAGE ETAF 0.25 6/11/2018 - &�o 5� SIGNED: DATE: 9 H U D e �A� ,may DIAL TWO WORKING m BEFORE DAYS BEFORE yF YOU DIG YOU DIG Q' TOLL FREE 1-800-227-2600 CG A PUBLIC SERVICE BY CVr.. UNDERGROUND SERVICE ALERT i CITY OF FONTANA NOTES: 1. RECIRCULATING WATER SYSTEMS SHALL BE USED FOR WATER FEATURES. 2. PRESSURE REGULATING DEVICES ARE REQUIRED IF WATER PRESS IS BELOW OR EXCEEDS THE RECOMMENDED PRESSURE OF THE SPECIFIED IRRIGATION DEVICES. 3. CHECK VALVES OR ANTI -DRAIN VALVES ARE REQUIRED ON ALL SPRINKLER HEADS WHERE LOW POINT DRAINAGE COULD OCCUR. 4. A DIAGRAM OF THE IRRIGATION PLAN SHOWING HYDRO -ZONES SHALL BE KEPT WITH THE IRRIGATION CONTROLLER FOR SUBSEQUENT MANAGEMENT PURPOSES. S. AN IRRIGATION AUDIT REPORT SHALL BE COMPLETED PER SECTION 28-106 WITHIN THE CITY OF FONTANA LANDSCAPE ORDINANCE #1734 AT THE SAME TIME OF FINAL INSPECTION. CITY OF FONTANA NOTE: ALL IRRIGATION SYSTEM DESIGNS THAT WILL BE MAINTAINED BY THE CITY OF FONTANA SHALL BE INSTALLED AS A RECYCLED WATER IRRIGATION SYSTEM FOR THE CURRENT AND FUTURE USE OF RECYCLED WATER AND SHALL BE DESIGNED AND OPERATED IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE LAWS. FRANK RADMACHER ASSOCIATES, INC. Landscape Architects PHONE (714) 832-1774 FAX (714) 832-5721 14841 Yorba Street, Suite 204 - Tustin, CA 92780 EMAIL: FRA1110@FRAINC.NET 1 • CITY OF FONTANA NOTE: DRIP INDICATORS CONTRACTOR SHALL INSTALL TWO (2) RAIN BIRD DRIP INDICATORS PER VALVE. ONE AFTER THE VALVE AND ONE AT THE END OF THE MANIFOLD SYSTEM. RAIN BIRD INDICATIOR MODEL #OPERID ITEM #X17500. rr. CITY OF FONTANA NOTE: AT THE TIME OF FINAL INSPECTION, THE PERMIT APPLICANT MUST PROVIDE THE OWNER OF THE PROPERTY WITH A CERTIFICATE OF COMPLETION, CERTIFICATE OF INSTALLATION, AND AN IRRIGATION SCHEDULE OF LANDSCAPE AND MAINTENANCE RE -i. NNDSCApF �p CAL\� r REOISION DESCRIPTION 2' BCH 40 SLEEVE L - - - - - - F -- - - - - --------- - - - - - -1- - - - - - - - - - O W 1 J LINE Oil SIO CT _ A5 ( El1„ 1 O 9.5 - - i J _ 1950 - - W _ t m - -.�� .T T. T � �►' T T-!� � �. �! T. -G- TW �- T� ter' T T •� �. �F V/ 01 ..'.'% IA4 18.0 180 PENNSYLVANIA AVE. ELECTRICAL POINT OF CONNECTION 'A' 24 STATION PEDESTAL CONTROLLER FOR C.F.D. LINE 00 SID CIT IRRIGATION. DEVELOPER SHALL PROVIDE 110-120 VAC ELECTRIC TO THIS LOCATION. LOT "B" ZONE NO./DESCRIPTION GENERAL IRRIGATION NOTES: HYpROZONE *I 1. This sprinkler system design is based on the minimum operating pressure shown on the irrigation drawings at each point of connection. The irrigation contractor shall verify water pressure on the W SHRUIBS 4 TREES / DRIP site prior to construction. Report any difference between the water pressure indicated on the Z HYDROZONE 02 drawings and the actual pressure reading at the irrigation point of connection to the Landscape 1 J SHRUBS 4 TREES / DRIP Architect and City Representative. HYDROZONE 03 2. The Developer shall provide required line voltage to the controller location(s). Irrigation ❑ V TREES / BUBBLERS contractor shall make final hook-up. Install No. 14 OF minimum direct burial irrigation wire t (black pilot, white common). Use epoxy connectors and bury wire with main line, bundled and ( Q feet. Form taped together every ten expansion coils at each remote control valve and change of direction. Install schedule 40 PVC sleeves under all paving. t 3. All piping between the point of connection and backflow preventer and/or vacuum breakers shall I be of materials and installation methods required by the local codes. 4. Irrigation contractor must stop all 'low head" drainage by installing appropriate in line check ' valves as necessary. 5. This design is diagrammatic. Equipment shown in paved areas is for design clarification only; actual equipment is to be installed within planted areas wherever possible. 6. Irrigation contractor shall flush all lines and adjust all valves for maximum performance. 7. Do not willfully install the system as designed when it is obvious in the field that unknown obs- tructions or grade differences exist that were not known during designing. Such conditions shall be brought to the attention of the Landscape Architect and Owner or Developer's representative; otherwise the irrigation contractor must assume full responsibility for any and all necessary revisions. 8. Install all components as called for by the City of Fontana irrigation guidelines and detail drawings. 9. Final location of automatic controllers, rain sensors, and valves shall be approved by the City representative prior to installation. Valve locations are shown for design clarity only. 10. It is the responsibility of the irrigation contractor to familiarize himself with all grade differences, locations of walls, walks, mow curbs, and turf locations edges, etc.. He shall coordinate his work with the general contractor and other sub -contractors for the location and installation of pipe sleeves through walls, under roadways, paving, structures, etc.. It. Contractor shall familiarize himself with Rain Bird dripline installation details and specifications prior to start of work. Contact Rain Bird representative Greg Steele at (949) 632-8627 for more information on proper slope layout to prevent low head drainage. Refer to Rain Bird details for proper location of all be equipment requried to installed for a complete system layout. Not all equipment is shown on plans. 12. Irrigation contractor shall be responsible for installing Sch. 40 sleeves for all lateral and pressure main- line under pavement. Sleeves shall be of sufficient size to be twice that of the irrigation line piping. 13. Sleeving for all pressure/non-pressure lines and wires under hardscape shall be installed pprior to paving Whe irriggation contractor. Sleeve all piping and wires under pavement a minimum of 24" deep with C SCH. 40 pipe sized two times the pipe diameter or wire bundle, larger if necessary. Extend sleeves 24" beyond pavement. Sleeves may not be shown under walks but shall be installed as noted above. 14. Contractor shall coordinate with the City of Fontana for all irrigation system components and requirements 1 for CFD areas. Controller model number, enclosure and options shall be per current City of Fontana I standard drawings. - 1 I F- 1" O❑S►C7❑T - 1" CONTINUE ' "A-11 "SYSTEM W ❑ U) -Al W U) A9 I,, END "A-10" 21.0 LOT "C" SYSTEM 210 9 IRRIGATION LEGEND 11 -ENTRY MONUMENT SIGN CYMBOI MANUFACTuRFR/MODFI NO-/DF3CRIPnoN DETAIL REF. RAIN BIRD MODEL NO. XFS DRIPLINE. BURIED 4" DEEP BELOW GRADE (6 GPH 0 18"). INSTALL IN ROWS D-H/L-8 18"-24" ON CENTER, DEPENDING UPON PLANT MATERIAL SPACING. START 2" AWAY FROM HARDSCAPE. r e INSTALL WITH ALL RAIN BIRD COMPRESSION FITTINGS AND COMPONENTS. INSTALL FLUSH VALVES AND AIR RELIEF VALVE FOR EACH SYSTEM -TYPICAL. REFER TO RAIN BIRD DETAILS. F_ 1 RAIN BIRD XFCV DRIPLINE w/ BUILT-IN CHECK VALVE. INSTALL ON GRADE FOR SLOPES. (.6 GPH 0 24") B/L -7 MODEL #XFCV-06-24-100. INSTALL IN ROWS 24' ON CENTER, START 2" AWAY FROM HARDSCAPE. S INSTALL WITH RAIN BIRD XF INSERT FITTINGS AND COMPONENTS. INSTALL FLUSH VALVES AND AIR RELIEF FOR j EACH SYSTEM -TYPICAL. SECURE DRIPLINE TO GRADE WITH RAIN BIRD TDS-050 BEND GALV. STAKES. L� (MIN. 6' ON CENTER SPACING). REFER TO RAIN BIRD DETAILS 0RAIN BIRD XFCV DOUBLE DRIPLINE TREE RING CA -7 • DEEP WATERING TREE BUBBLERS: RAIN BIRD RWS-M-8-1402 (0.5 GPM) /2 PER TREE EQUALLY SPACED AA -7 p REDUCED PRESSURE BACKFLOW PREVENTER- WILKINS #375 (PLASTIC) WITH WILKINS #600 XL-HLR-G. 5007A-6 (SAME SIZE AS MAINLINE). INSTALL IN A "GUARDSHACK" LOCKING - HINDGED ENCLOSURE (GREEN). RAIN BIRD #PESB-R-PRSD PRESSURE REDUCING/MASTER VALVE - LINE SIZE. SET DISCHARGE PRESSURE 501O-6 PRESSURE AS REQUIRED. VERIFY EXISTING PRESSURE BEFORE INSTALLING. / ® DATA INDUSTRIAL FLOW SENSOR MODEL #228PV3005 - INSTALL SAME SIZE AS MAINLINE. 501OA-6 EZ -FLOW FERTILIZER INJECTOR MODEL #EZ003-CX. LINE SIZE. INSTALL PER MANUFACTURER'S & CITY XA-7 SPECIFICATIONS. ►� NIBCO T-580 BRASS BALL VALVE OR EQUAL- LINE SIZE. INSTALL IN ROUND BOX. 5019A-6 3/4" RAINBIRD #33DLRC QUICK COUPLING VALVE w/RUBBER COVER IN BOX MARKED "QC" 5021A-9 ® RAIN BIRD IN-LINE DRIP ZONE KIT #XCZ-100-PRB-COM FOR FLOWS 3-20 GPM. INSTALL IN RECT. BOX 5038A-9 RAIN BIRD GB BRASS ELECTRIC CONTROL VALVE. INSTALL IN RECTANGULAR BOX. SIZES NOTED. 5011A-6 TORO SENTINAL CONTROLLER w/WIRELESS BOARD. MODEL #SBYPSS5U (8 OR 24 STATION) SEE PLAN -MOUNTED 5005,5006A-6 ® IN AN APPROVED STAINLESS STEEL NEMA RATED EDISON BOX ENCLOSURE. REFER TO DETAILS FOR ALL CITY REQUIREMENTS AND ACCESORIES. CONTACT DARYL GREEN AT GREEN PRODUCT SALES WHEN ORDERING AND TO SCHEDULE INSPECTION FOR CERTIFICATION. (949) 584-7311. GPS10CEARTHLINK.NET. (INSTALL SENTINAL ANTENNA ON THE TOP OF THE RAIN BUCKET POLE AND ELIMINATE RAIN BUCKET.) PENNSYLVANIA AVE. HAND HELD IRRIGATION RADIO CONTROLLER SHALL BE FULLY FUNCTIONAL AND TURNED OVER TO THE CITY OF FONTANA AT THE TIME OF FINAL ACCEPTANCE. DOMESTIC WATER METER PER FONTANA WATER (EXISTING). SIZES NOTED. PRESSURE MAIN LINE PIPING. USE PVC SCH. 40 / BURY MINIMUM 18" DEEP. SIZES NOTED. 5016A-6 NON -PRESSURE LATERAL LINE PIPING -USE SCH. 40 PVC. BURY MINIMUM 12" DEEP. 5016A-6 :.:............:... SCH. 40 PVC IRRIGATION SLEEVE UNDER PAVEMENT / SIZE 2 X PIPE OR WIRE BUNDLE 5018A-6 CITY OF FONTANA NOTE; PRESSURE REGULATION PRESSURE REGULATORS SHALL BE INSTALLED ON THE IRRIGATION SYSTEM ENSURING THAT DYNAMIC PRESSURE OF THE SYSTEM IS WITHIN THE MANUFACTURER'S RECOMMENDED PRESSURE RANGE. DATE EN7R. CITY DATE SGOULD CONSTRUCTION OD TOE REQUIRED IMPROCEMENTS NOT COMMENCE C ITAN TO O YEARS OO TOE DATE OGAPPROCAL SOOO N ❑EREON AND CARRIED OORTO IN A DILIGENT MANNER, TOE CITY ENGINEER MAY REQUIRE RECISIONS TO TOE PLANS TO BRING TCEM INTO CONCORMANCE C ITC CONDITIONS AND STANDARDS IN EOOECT. CONTROLLER STATION VALVE SIZE FLOW IN G.PM, HYDROZONE AREA (SQ. FT.) �4YDROZONE LEG ND ZONE NO./DESCRIPTION WUCOLS HYpROZONE *I LOW -MEDIUM SHRUIBS 4 TREES / DRIP HYDROZONE 02 LOW SHRUBS 4 TREES / DRIP HYDROZONE 03 MEDIUM -LOW TREES / BUBBLERS BASIS OF BEARINGS: I HL BASIS OF BEARINGS WAS I AKEN FROM THE CENTERLINE OF CITRUS AVENUE AS SHOWN ON TRACT 16540, M.B. 299/13-15. BEING: N00°16'44"W BENCHMARK: DRAT N BY: K NO. 8-17 � "1 GI I BRASS CAP IN CONCRETE S.C.E. TOWER LEG. 343' N/0 HIGHLAND AVENUE, 0.2 MI W/O SAN SEVAINE ROAD, IN SOUTH CONCRETE BASE OF S.C.E. TOWER 19.5; 2.65 MI. WEST C-iECKED BY: ALONG HIGHLAND AVENUE FROM SIERRA AVENUE EL=1428.6199 1 CITY O❑ ❑ONTANA, CALI❑ORNIA IRRI❑ATION PLAN CITRUS 105 TR. 18981 FONTANA, CALIFORNIA APPROCED BY: r 1"1_20❑ TE: 81212018 A171 IN[- NO.: 2