HomeMy WebLinkAboutTemplate ToolIvW
!
II I
I
UAI
O
�j Ir — I VPAD LINE
bo
> \II y
�Q00
00I CORNER MONUMENT
�W LANDSCAPE
PER SEPARATE \
I Z �Z PACKAGE PREPAREDry ` AR Fv I I
II
I FV
�CL BY SITESCAPES _ I I I'
�
------ 2 ----------- --- —�_-
I I I 1
1 '
l 1 FV
II
(1
,Li I
-,_ _- -- -- - �
-
I I I �
�Il I I I
II II
II C II
Q0 I I m I I 4�- I I
III II II
II I1 {I
II
I II II
II II II
I li n I II I II
, L 8. 2 B 3 B
,.9 .3.0 CYPRESS
35'11 6F 2318 8P 2� gp
1
- APPROVED STAINLESS STEEL EDISON METER BOX ENCLOSURE PER CFD
STANDARDS. HAND HELD IRRIGATION RADIO CONTROLLER SHALL BE FULLY
,
FUNCTIONAL AND TURNED OVER TO THE CITY OF FONTANA AT THE TIME OF
m
W
FINAL ACCEPTANCE. CONTRACTOR TO INSTALL A TORO SENTINEL EXTERNAL
__ _ �� -- - } ANTENNA ON THE TOP OF A POLE BY DAVIS INSTRUMENTS. SECURE THE POLE F
TO THE SIDE OF CONTROLLER ENCLOSURE. INSTALL PER MANUFACTURER'S
—I _ r� .—_..— SPECIFICATIONS. f
VERIFY LOCATIONS WITH EDISON AND THE CITY INSPECTOR PRIOR TO
PURCHASE OR INSTALLATION OF THE ENCLOSURE. SEE SITE ELECTRICAL
PLANS PRIOR TO STARTING JOB.
POINT OF CONNECTION: 'B' (POTABLE WATER)
1 1/2" WATER METER, REFER TO CIVIL PLANS. CONTRACTOR TO INSTALL A \
PAD LINE 2" WILKINS 375 XL SERIES REDUCED PRESSURE BACKFLOW PREVENTER W/
2" WYE STRAINER - LOCATE IN A LEMEUR VANDAL- RESISTANT STEEL MESH
(TYP.) ENCLOSURE. COORDINATE LOCATION WITH CITY INSPECTOR. (SCREEN
�� WITH SHRUBS)
RESIDUAL PRESSURE: 114.0 PSI
j; DESIGN PRESSURE: 61.7 PSI
C -n MAXIMUM DEMAND 19.8 GPM
bo 00 C
II II I II
I I f l I I I I
I I I I
I
FV I II I II � I I i t Fv �
j PAD LINE PAD LINE
I I, I �
II
(TYP.) i i� I (TYP.)�
II �I I1 I IOW
�➢00 CD
Ems-+
I I I I � I I I li■
4R FV I , I I I I I FY
L
4 B
" 102
2048 °..P
M U r '
5 B
I" 137
2740 eF _
1 ■
F
F-
1
W 2 I I x
W -'ll
I vJ
z ENTRY LANDSCAPE -�
W PER SEPARATE
PACKAGE
PREPARED BY k<1
p Q i SITESCAPES < X,
aI
A
-____- ____ -=__ -- =»
I InnILO.E.IAlLI&_--
A
ta
INSTALLATION NOTE:
- CONTRACTOR TO RUN (16) REMAINING CONTROL W1IRES
AND (1) COMMON WIRE (LABELED) TO THIS LOCATION
FOR FUTURE USAGE. PROVIDE 36" LOOP WITHIN AN
APPROVED LABELED VALVE BOX.
- CONTRACTOR TO CAP MAINLINE AT THIS LOCATION FOR
FUTURE PHASE ON CYPRESS AVENUE. LOCATE
BENEATH APPROVED LABELED VALVE BOX.
SEE SHEETS • FOR IRRIGATION NOTES, LEGEND & DETAILS
SCALE
1"a20'
S I T IE i C A P E S
Landscape Architecture
and Planning
3190 62 Airport Loop Drive
Costa Mesa, CA 92626
Richard Polhamus. License CA—#2782
(949) 644-9370 (714) 210-3140 FAX
F
REVISION
E� 00SCAPF
��R ARD A POI Bq
2782 y
W
3/17/17
DATE 3r%
PLAN CHECK NO.
DATE 01/16/17
JOB #
16-026
L8
OF 10