HomeMy WebLinkAbout5716-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION
PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO
WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS.
CALL (909) 350-7610.
3. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES. CONTRACTOR
SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER
REQUIREMENTS.
4. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
5. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
6. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION,
HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE
TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
7. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED
GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
8. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT
NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE
IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND
CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK
AROUND THEIR FACILITIES.
9. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD,
WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
10. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED
BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY
REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
11. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
12. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE.
12A. ALL REINFORCED CONCRETE SHALL BE 3,250 PSI, AT 28 DAYS, PORTLAND CEMENT TYPE IV.
13. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
14. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES
LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
SAFETY.
15. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES
(5) FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
16. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
17. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
18. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS
OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
19. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
20. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
21. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE
THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS,
THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
24. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
25. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK
PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
26. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES.
A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
27. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING
A SEPARATE PERMIT FOR THAT PURPOSE.
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY
ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING
FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
30. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE "W.A.T.C.H. MANUAL", LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE
CITY TRAFFIC ENGINEER.
31. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
32. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
33. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF
THE CITY ENGINEER.
34. MINIMUM D -LOAD FOR ALL RCP STORM DRAIN PIPE IS 1350.
35. THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONCRETE PIPES
MUST BE INCREASED TO PROVIDE A MINIMUM OF 1-1/2" OVER THE REINFORCING
WHEN THE DESIGN VELOCITIES EXCEED 20 FEET PER SECOND. THE CONCRETE
DESIGN STRENGTH IN THESE REACHES SHALL BE Fc=5000 psi FOR VELOCITIES
EXCEEDING 20 FEET PER SECOND AND Fc=6000 psi FOR VELOCITIES EXCEEDING
30 FEET PER SECOND.
36. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT
SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS.
NOTE:
OWNER/DEVELOPER
IDI GAZELEY C/O IDIG LIVE OAK, LLC
8 CORPORATE PARK, SUITE 300-34
IRVINE, CA 92606
PH: (949) 351-7243
CONTACT: STEVE HOLLIS
CIVIL ENGINEER
HUITT-ZOLLARS, INC
3990 CONCOURS, #330
ONTARIO, CA. 91761
PHONE (909) 941-7799
FAX (909) 941-7789
CONTACT: JOHNNY MURAD
UTILITY CONTACTS
ELECTRICITY
SOUTHERN CALIFORNIA EDISON
7951 REDWOOD AVENUE
FONTANA, CA 92336
(909) 357-6203
WATER
FONTANA WATER CO.
15966 ARROW ROUTE
FONTANA, CALIFORNIA 92335
(909) 822-2201
GAS
SOUTHERN CALIFORNIA GAS CO.
1981 W. LUGONIA AVENUE
REDLANDS, CA 92374
(800) 427-2200
DIGII,vtR,
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG YOU DIG
TOLL FREE: 811 WWW.DIGALERT.ORG
A PUBLIC SERVICE =ALERT
UNDERGROUND SERVICE
BASIS OF BEARINGS: BENCHMARK:
THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA COORDINATE SYSTEM, ZONE 5, THE BENCHMARK FOR THIS
NAD 83 (EPOCH 2011.00) AS DETERMINED LOCALLY BY A LINE BETWEEN CONTINUOUS GLOBAL PROJECT IS BASED ON THE
POSITIONING STATIONS (CGPS) AND/OR CONTINUOUS OPERATING REFERENCE STATIONS (CORS) NATIONAL GEODETIC SURVEY (NGS)
EWPP AND RTHS BEING S 84° 19'29.60" E AS DERIVED FROM GEODETIC VALUES PUBLISHED BY VERTICAL CONTROL NETWORK.
THE CALIFORNIA SPATIAL REFERENCE CENTER (CSRC) AND/OR NATIONAL GEODETIC SURVEY (NGS), BENCHMARK NUMBER PID EV9267
RESPECTIVELY. ALL DISTANCES ARE U.S. FEET (GRID). GROUND DISTANCES CAN BE OBTAINED DESIGNATION OF -628, ELEVATION
BY MULTIPLYING A COMBINATION FACTOR OF 0.99995585. 1006.35' (NAVD88).
10111_=[8mik 0
AT&T
3939 E CORONADO STREET
ANAHEIM, CA 92807
(714) 237-6155
SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-6632
CABLE
SPECTRUM
1500 AUTO CENTER DRIVE
ONTARIO, CA 91761
(800) 892-2253
REVISION DESCRIPTION
4k
IT
_Nby
M4 P Im FmAd F A00 1
IL
STORM DRAIN CONSTRUCTION NOTES
THE QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE
THEIR OWN QUANTITIES AND BID A COMPLETE JOB.
A. CONTRACTOR TO ADJUST ALL VALVE COVERS AND MANHOLE RIMS TO GRADE
AFTER FINAL PAVING HAS BEEN INSTALLED.
e /s« d
FUTURE DEVELOPMENT
SD MH##1
DATE I ENGR. I CITY I DATE
SHEET INDEX MAP
SCALE: 1"=100'
SHOULD CONSTRUCTION OF THE
REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE
WITH STANDARDS IN EFFECT.
� Q�OFESS/Q�q�
NO. 67512
EXPIRATION
6-30-2019
*T CIVIL
9TF OF CWE��
SHEET INDEX
SHT NO.
QUANTITIES
D7
INSTALL 18" RCP (D -LOAD AS SHOWN ON PLANS)...............................................................................
80
LF
D9
INSTALL 24" RCP (D -LOAD AND PROFILE AS SHOWN ON PLANS).............................................................
174
LF
D,0
INSTALL 30" RCP (D -LOAD AND PROFILE AS SHOWN ON PLANS) .................................. I..........................
39
LF
D14
INSTALL 48" RCP (D -LOAD AND PROFILE AS SHOWN ON PLANS)............................................................
696
LF
X27
CONSTRUCT 6'X2' RCB PER SPPWC STD. 390-1 (MODIFIED TO CAST -IN-PLACE) ........................................
89
LF
STD .........
AND USE A 6'X3'X7" STRUCTURAL CALCS AND SPECS.
SEW .... ;.....
SEWER
D48
INSTALL 36" CMP INLET PER DETAIL ON SHEET 4...............................................................................
1
EA
D50
CONSTRUCT CURB OPENING CATCH BASIN PER CITY OF FONTANA STD. 3004
DWG .........
DRAWING
EXIST..........
(WIDTH & V -DEPTH PER PLAN).......................................................................................................
3
EA
D51
CONSTRUCT MODIFIED CURB OPENING CATCH BASIN CASE I PER SPPWC STD.
UT .........
UTILITY
MH .........
PLAN 314-3, Y=3.5', SEE DETAIL ON SHEET 4...................................................................................
1
EA
D58
CONSTRUCT MANHOLE PER CITY OF FONTANA STD. PLAN 3012...............................................................
1
EA
D60
CONSTRUCT JUNCTION PIPE TO PIPE PER CITY OF FONTANA STD. PLAN 3009 ............................................
1
EA
D61
CONSTRUCT JUNCTION PIPE TO PIPE PER CITY OF FONTANA STD. PLAN 3010 ............................................
2
EA
D64
CONSTRUCT MANHOLE PIPE TO PIPE PER CITY OF FONTANA STD. PLAN 3011 .............................................
2
EA
os7
CONSTRUCT TRANSITION STRUCTURE RCB TO PIPE PER SPPWC STD. PLAN 342-2
EXISTING ELECTRICAL
_..... _ ___ .. _ _
EASEMENT
SEEDETAIL ON SHEET 4...............................................................................................................
2
EA
D68
CONSTRUCT CONCRETE COLLAR FOR RCP PER FONTANA STD. PLAN 3022 ................................................
1
EA
D70
CONSTRUCT PIPE BRICK AND MORTAR PLUG PER DETAIL ON SHEET 4 ......................................................
2
EA
D82
REMOVE EXIST. CONCRETE HEADWALL...............................................................................................
1
EA
D83
REMOVE PORTION OF EXISTING RCP (LIMITS AS INDICATED ON PLAN) .......................................................
39
LF
D84
INSTALL END CAP TO EXISTING STORM DRAIN.....................................................................................
1
EA
Di26
ADJUST MANHOLE RIM TO GRADE AFTER FINAL SURFACE HAS BEEN INSTALLED ..........................................
3
EA
0
SAWCUT AND REMOVE EXISTING AC/AB, LIMITS AND TRENCH PER CITY OF
FONTANA STD. PLAN 1008 AND AS INDICATED ON PLAN......................................................................
2,570
SF
D132
REMOVE EXISTING AC BERM & SOIL MATERIAL AND REPLACE IN KIND WITH
TRENCH PER CITY OF FONTANA STD. PLAN 1008 AND AS INDICATED ON PLAN ...........................................
280
SF
D13s
CONSTRUCT CONCRETE BLANKET PROTECTION PER SPPWC STD.
PLAN225-2 ON SHEET 4..............................................................................................................
6
EA
e /s« d
FUTURE DEVELOPMENT
SD MH##1
DATE I ENGR. I CITY I DATE
SHEET INDEX MAP
SCALE: 1"=100'
SHOULD CONSTRUCTION OF THE
REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE
WITH STANDARDS IN EFFECT.
� Q�OFESS/Q�q�
NO. 67512
EXPIRATION
6-30-2019
*T CIVIL
9TF OF CWE��
SHEET INDEX
SHT NO.
DESCRIPTION
1
TITLE SHEET
2
LIVE OAK AVE. STORM DRAIN PLAN AND PROFILE
3
JURUPA AVE. STORM DRAIN PLAN
4
STANDARD DETAILS
5
STANDARD DETAILS
LEGEND
- -
EXISTING R/W
- -
PROPOSED R/W
LOT LINE
-
CENTER LINE
AK
FIRE HYDRANT
.........
PROPERTY LINE
R/W ..........
RIGHT OF WAY
C .........
CENTERLINE
BOT. .......
BOTTOM
SD .......
STORM DRAIN
SMH .........
SEWER MANHOLE
STD .........
STANDARD
SEW .... ;.....
SEWER
TYP...........
TYPICAL
IMP...........
IMPROVEMENT
P.I.P..........
PROTECT IN PLACE
DWG .........
DRAWING
EXIST..........
EXISTING
RW ..........
RECYCLED WATER
INV .........
INVERT OF PIPE
UT .........
UTILITY
MH .........
MANHOLE
SPPWC.........
STANDARD PLANS FOR
PUBLIC WORKS CONSTRUCTION
PROPOSED STORM DRAIN
-
-- ---- -
EXISTING SEWER
- - - W- - ---
EXISTING WATER
____-- ---
EXISTING RECYCLED WATER
EXISTING STORM DRAIN
-�
EXISTING GAS
---
EXISTING TELEPHONE
EXISTING ELECTRICAL
_..... _ ___ .. _ _
EASEMENT
TRENCH REPAIR
UNAUTHORIZED CHANGES AND USES NOTESm
CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE
FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS.
CITY ACCEPTANCE OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR
THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON
REQUEST OF THE CITY INSPECTOR, THE REQUIRED PLAN REVISIONS SHALL BE PROMPTLY
SUBMITTED TO THE CITY ENGINEER FOR REVIEW.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE
AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND,
INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL
OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING
LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL.
PRIVATE ENGINEER'S NOTICE TOCONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON
THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR
KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES
SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS.
ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO THESE
PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE PLACE
TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS SHALL
COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE U.S. DEPARTMENT OF
LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS' "CONSTRUCTION
SAFETY ORDERS".
THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTORS' AND
SUBCONTRACTORS' COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF
THE U.S. DEPARTMENT OF LABOR OR WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL
RELATIONS' "CONSTRUCTION SAFETY ORDERS".
CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR
JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY
OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT
BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY
AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR
ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR ANY
LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR ENGINEER.
ELPC17-00045 / TPM#17-001 / DRP#17-004
lul
Amw y
IARS I
Huitt-Zollars, Inc. Ontario DRAWN BY: SCALE:
3990 CONCOURS, #330 * ONTARIO, CALIFORNIA 91761 * (909) 941-7799 R. P. TITLE SHEET AS SHOWN
A
PREPARED UNDER THE SUPERVISION OF: JOHNNY M U RAD
6.7512
. . i. 018
�CHECKED Y:
`PPR#
D
• ,. - i
- 11
-../
EXPIRES D.CITYENGINEER DATE: •