Loading...
HomeMy WebLinkAbout5708-71050 N,LY TC 1050 CL 1050 S' LY TC F3 ,6� O O Mr Q F - 0)W I I Wco Z —W � I J U Q F a o^ 0 0 2 o o ^_ o N 121 6 0 0 o� 00°4 +� oc'i o^ Cl CN ,) o M + 8 rn N M p r7 v O + M O ....... CD O r� O O6 Obi 6 co 0 o -- _- CO �O_ r O EXISTING GRADE `0 34' N/0 CENTERLINE ^ CD o C> ,� 6 v o ^ O^ O O O N O N O ^) O N O A� (o IN I CD M O + O O ^ 06 — --- - ---- -_� -- tos' + 'n M M O PROP. TOP OF CURB C) 0 34' S/O CENTERLINE O M + (o M 0.55% —7— EXISTING GRADE 0 34' S/0 CENTERLINE 31+00 W, O O Ira 00 Q cow I I Wco ZW —W co I U Q 32+00 L=23.19' CURVE # L=23.19' CURVE J LENGTH CURVE K J 66'25'19" 20.00' 23.19' 13.09' K m O O '6O O O 01F - M (n 04 n N 90'07'27" +,� CV MU Ul � M� �� LO O O O O M� 0 77f._ .7 TC FL ph0 .0 F0.55% p 1048.75FL C) ^ V j �U_ m� O p ,��~w O O N O NO F�po�'G0 o C) FLOW Mfoo ^ , 0 DWY ~' 50.00' VC PVI STA: 33+25.00 PVI ELEV:1052.57 33+00 34+00 EX. GRADE _ ® CENTERLINE 35+00 1.307. H N n L=78.65' CURVE L H L C) o MN N Oi aj OCD 'f 36+00 1050 N LY T C LL 1050 CYPRESS " CL AVENUE W SEE PHASE II STREET IMPROVEMENT PLANS N W It + Z oo r/ I W Q W 1050 W O r^ V, S'LY TC I �W WIL Co Z>- :10 I _ U PROFILE SCALE: Q HORIZ. - 1" = 40' VERT. - 1" = 4' 37+00 SANTA PAVEMENT LEGEND - REMOVE EXISTING AC PAVEMENT - CONSTRUCT NEW ASPHALT PAVEMENT - CONSTRUCT NEW PCC SIDEWALK - GRIND AND OVERLAY - CONSTRUCT PCC IMPROVEMENTS SEE DETAIL SHEET 1 ANA BENCH MARK: CITY OF FONTANA BENCHMARK NO. "289» FOUND RAILROAD SPIKE IN THE NORTHWEST SIDE OF POWERPOLE NUMBER 61319 AT THE NORTHEAST CORNER OF THE INTERSECTION OF SANTA ANA AVENUE AND CATAWBA AVENUE. ELEVATION = 1032.22' AVENUE TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. F I / SEE SHEET 8 KAATCHLINE - STA 36+42 45 ECR CYPRESS AVE. n 0 CURVE TABLE CURVE # DELTA RADIUS LENGTH TANGENT J 66'25'19" 20.00' 23.19' 13.09' K 6625'19" 20.00' 23.19' 13.09' L 90'07'27" 50.00' 78.65' 50.11' J V1'1 LL. I —LV SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT. 0 20 40 80 120 SCALE:1 "=40' QROFESS/pN- O l S�Ftiyc� WW �� * R.C.E. NO. 56155 r - (f Exp. 12-31-18 Q o�� OF C A \_ SANTA ANA AVE. &CYPRESS AVE S/W CURB RETURN ACCESS RAMP PER STD. PLAN NO 1003 SCALE: 1"=20' CONSTRUC-nON NOTES: 0 SAW -CUT & REMOVE EXISTING A.C. PAVEMENT. 2O PROPOSED TRAFFIC SIGNAL - SEE SIGNAL PLANS O REMOVE ALL EXISTING TREES/SHRUBS/TREES STUMPS WITHIN PUBLIC R/W. 4O REMOVE EXISTING CURB AND GUTTER 5 REMOVE EXISTING SIDEWALK 6 REMOVE EXISTING AC BERM 0 UNDERGROUND EXISTING POWER POLE BY OTHERS (FOR REFERENCE) OREMOVE & RECONSTRUCT EXISTING RESIDENTIAL DRIVEWAY PER CITY OF FONTANA STD. PLAN 1002. (WIDTH PER PLAN) 9O CONSTRUCT 8" CURB AND GUTTER PER CITY OF FONTANA STD. PLAN 1000 10 CONSTRUCT SIDEWALK PER FONTANA STD. PLAN 1006. (WIDTH PER PLAN & DETAILS) 11 CONSTRUCT CURB RETURN ACCESS RAMP PER CITY OF FONTANA STD. PLAN 1003. 12 CONSTRUCT 4" A.C. OVER 6" A.B. OVER 12" OF NATIVE (COMPACTED TO 95%) FOR NEW PAVING IN OLEANDER AVENUE (T.I.=6.5) 13 CONSTRUCT 5-1/2" A.C. OVER 10" A.B. OVER 12" OF NATIVE (COMPACTED TO 95%) FOR NEW PAVING IN SANTA ANA AVENUE (T.I.=9.0) 14 CONSTRUCT 5-1/2" A.C. OVER 10" A.B. OVER 12" OF NATIVE (COMPACTED TO 95%) FOR NEW PAVING IN CYPRESS AVENUE (T.I.=9.0) 15 CONSTRUCT COMMERCIAL DRIVEWAY PER CITY OF FONTANA STD. PLAN 1002 (MODIFIED AS PER DETAILS ON SHEET 2). 16 CONSTRUCT PARKWAY PLANTER BOX DETAIL PER DETAIL ON SHEET 2. 17 PROPOSED FIRE SERVICE TO BE INSTALLED (BY FONTANA WATER COMPANY). 18 PROPOSED FIRE D.D.C.A. TO BE INSTALLED (BY FONTANA WATER COMPANY). 19 PROPOSED FIRE HYDRANT TO BE INSTALLED (BY FONTANA WATER COMPANY) 20 PROPOSED DOMESTIC WATER SERVICE TO BE INSTALLED (BY FONTANA WATER COMPANY) 21 PROPOSED IRRIGATION WATER SERVICE TO BE INSTALLED (BY FONTANA WATER COMPANY) 22 PROPOSED CATCH BASIN - SEE STORM DRAIN PLANS 23 PROPOSED STREET LIGHT - SEE STREET LIGHT PLANS 24 REMOVE OR RELOCATE EXISTING STREET LIGHT - SEE STREET LIGHT PLANS 25 REMOVE OR RELOCATE EXISTING CATCH BASIN - SEE STORM DRAIN PLANS 26 REMOVE EXISTING WATER METER (BY FONTANA WATER COMPANY) 27 RELOCATE EXISTING WATER METER (BY FONTANA WATER COMPANY) 28 ADJUST EXISTING MANHOLE TO GRADE 29 REMOVE EXISTING STAND PIPE 30 REMOVE/RELOCATE EXISTING STREET SIGN PER CITY OF FONTANA STD. 4003 31 REMOVE EXISTING BLOCK WALL 32 REMOVE EXISTING FENCE 33 REMOVE EXISTING STRUCTURE 34 REMOVE EXISTING STORM DRAIN STRUCTURE - SEE STORM DRAIN PLANS 35 REMOVE EXISTING WATER FACILITIES BY OTHERS 36 REMOVE EXISTING DRIVEWAY 37 CONSTRUCT 6.5" MIN. A.C. OVER 8" A.B. OVER 12" OF NATIVE (COMPACTED TO 95%) FOR NEW PAVEMENT IN JURUPA AVENUE 38 PROTECT IN PLACE EXISTING STREET LIGHT 39 GRIND AND OVERLAY EXISTING PAVEMENT. 5' WIDTH MIN. 40 RELOCATE EXISTING COMM. PULL BOX. 41 CONSTRUCT 6" CURB PER CITY OF FONTANA STD. PLAN 1000 42 ADJUST TO GRADE EXISTING WATER VALVE 43 REMOVE EXISTING TREES, LANDSCAPING AND UNDERGROUND EXISTING IRRIGATION SYSTEM TO CONTINUE BEYOND THE LIMITS OF PROPOSED MEDIAN IMPROVEMENTS. 44 PROTECT IN PLACE EXISTING MANHOLE COVER 45 REMOVE EXISTING MEDIAN CURB 46 CONTRACTOR TO CONTACT SAN GABRIEL VALLEY WATER COMPANY IN REGARD TO EXISTING CONCRETE WATER LINES AND CONFLICTS WITH ROAD IMPROVEMENTS Prepared Under The Supervision Of Thienes Engineering, lnc. C1WL ENGINEERING • LAND SURVEKNG 14349 FIRESTONE BOULEVARD DRAWN BY: LA MIRADA, CALIFORNIA 90638 PH.(714)521-4811 FAX(714)521-4173 G.P. G.P. Date :*RWtff CHECKED BY. REINHARD STE ZEL RCE NO. 56155 M.R. WD/D# 8-36C382506 DRP 15-017 CITY OF FONTANA, CALIFORNIA V) STREET IMPROVEMENT PLAN W SANTA ANA AVENUE SCALE: FROM STA.31+00.00 TO CYPRESS AVENUE AS SHOWN 0 SOUTH WEST FONTANA LOGISTICS CENTER DATE: moi' S/W CORNER SANTA ANA AND CYPRESS AVE N AP D BY: /�' DRAWING NO.: 7 � g �li��C" DATE: �' ' �� .5708 PO C15; NGINEER R.C.E. 51152 7 -9 6 1050.44TC 1049.77FL L 1050.16TC 1049.49FL 1049.30 _T sr•1049.22TF 00 0" 0° 104 104 .7 TC FL ph0 .0 p 1048.75FL F�po�'G0 SANTA ANA AVE. &CYPRESS AVE S/W CURB RETURN ACCESS RAMP PER STD. PLAN NO 1003 SCALE: 1"=20' CONSTRUC-nON NOTES: 0 SAW -CUT & REMOVE EXISTING A.C. PAVEMENT. 2O PROPOSED TRAFFIC SIGNAL - SEE SIGNAL PLANS O REMOVE ALL EXISTING TREES/SHRUBS/TREES STUMPS WITHIN PUBLIC R/W. 4O REMOVE EXISTING CURB AND GUTTER 5 REMOVE EXISTING SIDEWALK 6 REMOVE EXISTING AC BERM 0 UNDERGROUND EXISTING POWER POLE BY OTHERS (FOR REFERENCE) OREMOVE & RECONSTRUCT EXISTING RESIDENTIAL DRIVEWAY PER CITY OF FONTANA STD. PLAN 1002. (WIDTH PER PLAN) 9O CONSTRUCT 8" CURB AND GUTTER PER CITY OF FONTANA STD. PLAN 1000 10 CONSTRUCT SIDEWALK PER FONTANA STD. PLAN 1006. (WIDTH PER PLAN & DETAILS) 11 CONSTRUCT CURB RETURN ACCESS RAMP PER CITY OF FONTANA STD. PLAN 1003. 12 CONSTRUCT 4" A.C. OVER 6" A.B. OVER 12" OF NATIVE (COMPACTED TO 95%) FOR NEW PAVING IN OLEANDER AVENUE (T.I.=6.5) 13 CONSTRUCT 5-1/2" A.C. OVER 10" A.B. OVER 12" OF NATIVE (COMPACTED TO 95%) FOR NEW PAVING IN SANTA ANA AVENUE (T.I.=9.0) 14 CONSTRUCT 5-1/2" A.C. OVER 10" A.B. OVER 12" OF NATIVE (COMPACTED TO 95%) FOR NEW PAVING IN CYPRESS AVENUE (T.I.=9.0) 15 CONSTRUCT COMMERCIAL DRIVEWAY PER CITY OF FONTANA STD. PLAN 1002 (MODIFIED AS PER DETAILS ON SHEET 2). 16 CONSTRUCT PARKWAY PLANTER BOX DETAIL PER DETAIL ON SHEET 2. 17 PROPOSED FIRE SERVICE TO BE INSTALLED (BY FONTANA WATER COMPANY). 18 PROPOSED FIRE D.D.C.A. TO BE INSTALLED (BY FONTANA WATER COMPANY). 19 PROPOSED FIRE HYDRANT TO BE INSTALLED (BY FONTANA WATER COMPANY) 20 PROPOSED DOMESTIC WATER SERVICE TO BE INSTALLED (BY FONTANA WATER COMPANY) 21 PROPOSED IRRIGATION WATER SERVICE TO BE INSTALLED (BY FONTANA WATER COMPANY) 22 PROPOSED CATCH BASIN - SEE STORM DRAIN PLANS 23 PROPOSED STREET LIGHT - SEE STREET LIGHT PLANS 24 REMOVE OR RELOCATE EXISTING STREET LIGHT - SEE STREET LIGHT PLANS 25 REMOVE OR RELOCATE EXISTING CATCH BASIN - SEE STORM DRAIN PLANS 26 REMOVE EXISTING WATER METER (BY FONTANA WATER COMPANY) 27 RELOCATE EXISTING WATER METER (BY FONTANA WATER COMPANY) 28 ADJUST EXISTING MANHOLE TO GRADE 29 REMOVE EXISTING STAND PIPE 30 REMOVE/RELOCATE EXISTING STREET SIGN PER CITY OF FONTANA STD. 4003 31 REMOVE EXISTING BLOCK WALL 32 REMOVE EXISTING FENCE 33 REMOVE EXISTING STRUCTURE 34 REMOVE EXISTING STORM DRAIN STRUCTURE - SEE STORM DRAIN PLANS 35 REMOVE EXISTING WATER FACILITIES BY OTHERS 36 REMOVE EXISTING DRIVEWAY 37 CONSTRUCT 6.5" MIN. A.C. OVER 8" A.B. OVER 12" OF NATIVE (COMPACTED TO 95%) FOR NEW PAVEMENT IN JURUPA AVENUE 38 PROTECT IN PLACE EXISTING STREET LIGHT 39 GRIND AND OVERLAY EXISTING PAVEMENT. 5' WIDTH MIN. 40 RELOCATE EXISTING COMM. PULL BOX. 41 CONSTRUCT 6" CURB PER CITY OF FONTANA STD. PLAN 1000 42 ADJUST TO GRADE EXISTING WATER VALVE 43 REMOVE EXISTING TREES, LANDSCAPING AND UNDERGROUND EXISTING IRRIGATION SYSTEM TO CONTINUE BEYOND THE LIMITS OF PROPOSED MEDIAN IMPROVEMENTS. 44 PROTECT IN PLACE EXISTING MANHOLE COVER 45 REMOVE EXISTING MEDIAN CURB 46 CONTRACTOR TO CONTACT SAN GABRIEL VALLEY WATER COMPANY IN REGARD TO EXISTING CONCRETE WATER LINES AND CONFLICTS WITH ROAD IMPROVEMENTS Prepared Under The Supervision Of Thienes Engineering, lnc. C1WL ENGINEERING • LAND SURVEKNG 14349 FIRESTONE BOULEVARD DRAWN BY: LA MIRADA, CALIFORNIA 90638 PH.(714)521-4811 FAX(714)521-4173 G.P. G.P. Date :*RWtff CHECKED BY. REINHARD STE ZEL RCE NO. 56155 M.R. WD/D# 8-36C382506 DRP 15-017 CITY OF FONTANA, CALIFORNIA V) STREET IMPROVEMENT PLAN W SANTA ANA AVENUE SCALE: FROM STA.31+00.00 TO CYPRESS AVENUE AS SHOWN 0 SOUTH WEST FONTANA LOGISTICS CENTER DATE: moi' S/W CORNER SANTA ANA AND CYPRESS AVE N AP D BY: /�' DRAWING NO.: 7 � g �li��C" DATE: �' ' �� .5708 PO C15; NGINEER R.C.E. 51152 7 -9 6