Loading...
HomeMy WebLinkAbout5691-9IvW ! II I I UAI O �j Ir — I VPAD LINE bo > \II y �Q00 00I CORNER MONUMENT �W LANDSCAPE PER SEPARATE \ I Z �Z PACKAGE PREPAREDry ` AR Fv I I II I FV �CL BY SITESCAPES _ I I I' � ------ 2 ----------- --- —�_- I I I 1 1 ' l 1 FV II (1 ,Li I -,_ _- -- -- - � - I I I � �Il I I I II II II C II Q0 I I m I I 4�- I I III II II II I1 {I II I II II II II II I li n I II I II , L 8. 2 B 3 B ,.9 .3.0 CYPRESS 35'11 6F 2318 8P 2� gp 1 - APPROVED STAINLESS STEEL EDISON METER BOX ENCLOSURE PER CFD STANDARDS. HAND HELD IRRIGATION RADIO CONTROLLER SHALL BE FULLY , FUNCTIONAL AND TURNED OVER TO THE CITY OF FONTANA AT THE TIME OF m W FINAL ACCEPTANCE. CONTRACTOR TO INSTALL A TORO SENTINEL EXTERNAL __ _ �� -- - } ANTENNA ON THE TOP OF A POLE BY DAVIS INSTRUMENTS. SECURE THE POLE F TO THE SIDE OF CONTROLLER ENCLOSURE. INSTALL PER MANUFACTURER'S —I _ r� .—_..— SPECIFICATIONS. f VERIFY LOCATIONS WITH EDISON AND THE CITY INSPECTOR PRIOR TO PURCHASE OR INSTALLATION OF THE ENCLOSURE. SEE SITE ELECTRICAL PLANS PRIOR TO STARTING JOB. POINT OF CONNECTION: 'B' (POTABLE WATER) 1 1/2" WATER METER, REFER TO CIVIL PLANS. CONTRACTOR TO INSTALL A \ PAD LINE 2" WILKINS 375 XL SERIES REDUCED PRESSURE BACKFLOW PREVENTER W/ 2" WYE STRAINER - LOCATE IN A LEMEUR VANDAL- RESISTANT STEEL MESH (TYP.) ENCLOSURE. COORDINATE LOCATION WITH CITY INSPECTOR. (SCREEN �� WITH SHRUBS) RESIDUAL PRESSURE: 114.0 PSI j; DESIGN PRESSURE: 61.7 PSI C -n MAXIMUM DEMAND 19.8 GPM bo 00 C II II I II I I f l I I I I I I I I I FV I II I II � I I i t Fv � j PAD LINE PAD LINE I I, I � II (TYP.) i i� I (TYP.)� II �I I1 I IOW �➢00 CD Ems-+ I I I I � I I I li■ 4R FV I , I I I I I FY L 4 B " 102 2048 °..P M U r ' 5 B I" 137 2740 eF _ 1 ■ F F- 1 W 2 I I x W -'ll I vJ z ENTRY LANDSCAPE -� W PER SEPARATE PACKAGE PREPARED BY k<1 p Q i SITESCAPES < X, aI A -____- ____ -=__ -- =» I InnILO.E.IAlLI&_-- A ta INSTALLATION NOTE: - CONTRACTOR TO RUN (16) REMAINING CONTROL W1IRES AND (1) COMMON WIRE (LABELED) TO THIS LOCATION FOR FUTURE USAGE. PROVIDE 36" LOOP WITHIN AN APPROVED LABELED VALVE BOX. - CONTRACTOR TO CAP MAINLINE AT THIS LOCATION FOR FUTURE PHASE ON CYPRESS AVENUE. LOCATE BENEATH APPROVED LABELED VALVE BOX. SEE SHEETS • FOR IRRIGATION NOTES, LEGEND & DETAILS SCALE 1"a20' S I T IE i C A P E S Landscape Architecture and Planning 3190 62 Airport Loop Drive Costa Mesa, CA 92626 Richard Polhamus. License CA—#2782 (949) 644-9370 (714) 210-3140 FAX F REVISION E� 00SCAPF ��R ARD A POI Bq 2782 y W 3/17/17 DATE 3r% PLAN CHECK NO. DATE 01/16/17 JOB # 16-026 L8 OF 10