HomeMy WebLinkAbout5691-20
0
Z
42A RVVIOM
LODGE POLE
TREE TRUNK
WONDER TIE
(DO NOT TWIST)
MD
VIRE AROUND
rO STAKE
NDATION
OF TREE
;EPOLE PINE STAKES:
DVE FINISH
NITROLIZED
PLANT IS
ARCH DIRECTION
RED
:TS.
E. REFER
r
)M
GE
WT.
5GAL -X= 6"
15 GAL -X=9"
24" BOX & LARGER - X = 12" MAX.
SIDEWALK (WHERE
SECTION
PLAN VIEW
1 1/2x ROOTBALL SIZE
TREE OR PALM TRUNK
ROOTBALL
3" DIA. SCH. 80
PVC STAND PIPE W/
PIPE CAP
LIMITS OF PLANT PIT
3" DIA. CORRUGATED A.D.S. PERFORATED
DRAIN PIPE W/ DRAIN SOCK LAID
BASE OF ROOTBALL
TREE TRUNK
ROOTBALL
— PIPE CAP
r— FIN. GR.
DIA. SCH. 80
STAND PIPE
I BACKFILL MIX
DOMPACTED SOIL
3ACKFILL
3" DIA. CORRUGATED
A.D.S. PERFORATED
DRAIN PIPE W/ DRAIN
SOCK LAID 0 BASE
OF ROOTBALL
NOTES:
O BURY A MINIMUM OF 1/3 DEPTH
OF BOULDER SIZE.
O BOULDER - SEE � ON SHEET
L1 FOR SPECIFICATION
O3 SCARRED OR BROKEN BOULDERS
SHALL NOT BE PERMITTED.
® PLACE PER PLANS AND
LANDSCAPE ARCHITECT'S DIRECTION
--1. ....,.,, 1-.-D SOIL
APPROX. BOULDER FOOTPRINT SIZES
2 2' X 2' X 2'= 8 CU/FT
fg' 3' X 3' X 3= 27 CU/FT
4' X 4' X 4' = 64 CU/FT
O TREE STAKING O PIT DRAIN DETAIL O BOULDER INSTALLATION DETAIL
2 3
HOLD ROOTBALL ABOVE ULTIMATE
II- FINISHED GRADE: 1
allI 1FOR 1 GAL FLUSH
2" FOR 5 & 15 GAL 5
E -
II II DG LAYER PER SPECIFICATIONS
-III III IIIIII Il I
=1111 IILII —,_ `
o J- T III= ft�� lJ N
SECTION ,..;:.,:`:,, I_I11- FERTILIZERGRO POWER TABLETS.
APPLICATION RATES PER ABLE.
o :.;:'
5 GRAM AGRIFORM HI � �. I I -. REFER TO SPECS.
TABLETS SEE SPECS. IIII�II �'- "III=II-VIII BACKFILL MIX PER NOTES.
1" DEEP DG MULCH LAYER ..IlLlllzl II II VIII °-11
Tiff
..........................:::::::::.:.:...:::::::...::::::: .
................:::.................... 8'
D / a as a.� TILLED & AMENDED PLANTING MIN. q
l a BED PER SOIL TEST
NATURAL SUBGRADE
O1 FINISH GRADE/ADJACENT PLANTING O7
F HOLD ROOTBALL ABOVE ULTIMATE
Q Q(i FINISHED GRADE: O2 PERMALOCK SPLICING STAKE/LINE STAKE, INSTALL PER
GROUNDCOVER PLANTS FINISH 1" FOR 1 GAL MANUFACTURER'S SPECIFICATIONS.
SEE PLANTING PLANS GRADE 2" FOR 5 & 15 GAL
FOR SPACING— DG LAYER PER SPECIFICATIONS O PERMALOCK 1/8" x 4" ML. FINISH ALUMINUM EDGING. NATURAL
ALUMINUM COLOR. INSTALL PER MANUFACTURER'S SPECIFICATIONS.
1" DEEP DG MULCH o J—IT�III ' • . a uI — I-
A 111 IT�II�III I�I�u�I TEMPORARY 2 HIGH WATER
= A BASIN. REMOVE ONCE PLANT IS O COMPACTED NATIVE SUB -GRADE
LAYER. � � I- - �;•;° : '�.
w o = `.®;' "' ESTABLISHED
of
- GRO POWER FERTILIZER TABLETS. O5 DECORATIVE ROCK MULCH PER PLAN - DEPTH VARIES O5
<,.
APPLICATION RATES PER TABLE.
PLAN I_,REFER TO SPECS.
rl=il�=lTt=ll�-- �lTl= ISI I-- BACKFILL MIX PER NOTES.
�4 GROUNDCOVER PLANTING I�5 SHRUB PLANTING lO PERMALOC ALUMINUM HEADER
STORM DRAIN/
UNDERGROUND UTILITIES
SEE NOTE 3
5
W SIDEWALK
UTI1 100,
LI
z
a
CURB AND GUTTER METER
10' 5'
TYP. TYP.
L
DERGROUND STRUCTURE
CH BASIN
NSFORMER VAULT.
.—.
SIDEWALK�_ L
DRIVE S.L. ❑ O xi0
APPROACH _
2 �
d
CURB AND GUTTER
MIN MIN MIN N
5'
NOTES: MIN
1. TREE SPACING SHALL CONFORM TO PLANS APPROVED BY
THE CITY ENGINEER AND FUEL MODIFICATION PLAN.
2. ALL TREES IN THE R.O.W. ARE SUBJECT TO LINE.OF.SIGHT
CRITERIA AS APPROVED BY TRAFFIC ENGINEER.
3. AT ALL LOCAL RESIDENTIAL INTERSECTIONS THE FIRST TWO
PARKWAY TREES AT ALL APPROACHES TO BE PLACED BEHIND SIDEWALK.
4. MAINTAIN 10 FEET FROM CENTER OF STREET TO EDGE
OF ALL UNDERGROUND FACILITIES.
Call Underground Service Alert 5. MAINTAIN 10 FEET FROM ALL STREET LIGHTS, UTILITIES
STRUCTURES AND VALVE BOXES.
� at least 2 days before you dig TT����``//��'(('
KnoCalIbsoreyou. O TREE PLA�ElYlENT
Call before you dig.
a
/ I I
I I I
4 6 i 17
\ I I
I
I. � �.ar '1 a •d .ai//
\
ALIGN W/ ALIGN W/
DRIPLINE DRIPLINE
OR OR
PER MFR. OF TREE PER MFR.
SPEC. SPEC.
ROOT BARRIER
NOTES:
A. POSITION BARRIER AS
CLOSE TO CURB OR
SIDEWALK AS POSSIBLE.
RAISED ROOT PROTECTORS
SHALL BE FACING
TOWARDS THE TREE.
B. TOP OF BARRIER SHALL
BE 1" ABOVE FINISHED
GRADE.
C. LENGTH OF ROOT BARRIER
SHALL BE EQUAL TO
THE ULTIMATE DRIPLINE OF
THE PARTICULAR TREE, OR
10' MAX.
LEGEND:
1Q CONCRETE CURB OR
HARDSCAPE
83 FINISHED GRADE
APPROVED ROOT CONTROL
BARRIER
® 3/4" TO 1 1/2" GRAVEL
OR CRUSHED ROCK
DRIP LINE OF TREE
6 CENTER OF TREE
PARKWAY WIDTH
ROOT BARRIER IS TO BE 18"
LINEAR BARRIER UB 18-2
WHEN ADJACENT TO WALK
OR HARDSCAPE OR 24"
LINEAR BARRIER
UB 24-2 WHEN ADJACENT
TO CURB
AVAILABLE FROM:
CENTURY PRODUCTS
1144 N. GROVE ST.
ANAHEIM, CA 92806
(714) 632-7083
WEED CONTROL
WHERE PERENNIAL WEEDS EXIST ON SITE AT THE BEGINNING OF WORK, CLEAN AND REMOVE
THESE EXISTING WEEDS BY MOWING OR GRUBBING OFF ALL PLANT MATERIAL. UPON
COMPLETION OF SOIL PREPARATION AND PLANTING OF ALL SPECIMEN TREES, BEGIN WEED
ABATEMENT PROGRAM BY APPLYING: 100 POUNDS OF A COMMERCIAL FERTILIZER, 46-0-0, PER
ACRE AND PER MANUFACTURER'S SPECIFICATIONS. WATER ALL AREAS FOUR (4) TIMES DAILY
FOR FOURTEEN (14) CONSECUTIVE DAYS UNTIL WEED SEEDS HAVE GERMINATED. CEASE
WATERING FOR THREE (3) DAYS. SPRAY A NON-SELECTIVE, NON -RESIDUAL, SYSTEMIC
HERBICIDE TO ERADICATE GERMINATED WEEDS. LET THE WEEDS DIE WITHOUT IRRIGATION
FOR A MINIMUM DEPTH OF 1/4"INCH BELOW THE SURFACE OF THE SOIL. IF STUBBORN AND
RESIDUAL WEEDS (I.E. BERMUDA) SHOULD PERSIST ERADICATION PROCEDURE SHOULD BE
REPEATED. THE TYPE OF WEEDS THAT EXIST SHOULD BE IDENTIFIED AND COORDINATED WITH
AN APPROVED LICENSED PEST CONTROL ADVISOR TO ENSURE COMPATIBILITY WITH CHEMICAL
AND SEASON OF APPLICATION. DO NOT USE MATERIAL OR METHOD THAT WOULD ADVERSELY
EFFECT NEW PLANTINGS, SLOPE STABILIZATION OR HYDROSEEDING.
SOIL TEST
AFTER ALL SOIL HAS BEEN IMPORTED TO THE SITE AND ROUGH GRADING COMPLETED BUT
PRIOR TO SOIL PREPARATION, SEVERAL SOIL SAMPLES SHALL BE TAKEN BY THE SOILS LABORATORY
OR BY THE CONTRACTOR AT THEIR INSTRUCTION AND A REPORT/RECOMENDATION
PRODUCED. THE CONTRACTOR SHALL FURNISH A COPY OF TIIE SOIL TEST FOR
AGRICULTURAL SUITABILITY AND FERTILITY (PREPARED BY A CALIFORNIA ASSOCIATION OF
AGRICULTURAL LABORATORIES MEMBER) TO THE CONTRACTING OFFICER AND THE CITIES INSPECTOR,
UPON REVIEWING THE SOILS REPORT THE ARCHITECT MAY MAKE SPECIES
SUBSTITUTIONS TO THE PLANT LIST.
SOIL PREPARATION
MACHINE ROTOTILL THE FOLLOWING AMENDMENTS INTO THE SOIL AT RATES INDICATED PER
1000 SF: (THESE RATES ARE FOR BID PURPOSES ONLY, ACTUAL RATES TO CORRESPOND TO
CONTRACTOR'S SOILS REPORT).
4 CU, YDS NITROGEN STABILIZED SAWDUST
150 LBS. GYPSUM
125 LBS STANDARD FERTILIZER
DEEP ROOT BARRIERS
ALL TREES WITHIN 7 FEET OF ANY PERMANENT HARDSCAPE ELEMENT SUCH AS CONCRETE
WALKS, WALLS OR BUILDINGS SHALL BE PLANTED WITH AN APPROPRIATE SIZED ROOT
BARRIER (UNLESS OTHERWISE NOTED ON PLANS). ROOT BARRIER TO BE LINEAR PANEL (TYP.)
SEE DETAIL.
TOP DRESSING (FUEL MODIFICATION AREA)
ALL SHRUB AND GROUNDCOVER AREAS SHALL BE TOP DRESSED WITH A V-1/2" LAYER OF DECOMPOSED
GRANITE/FRACTURED ROCK. SEE TOP DRESSING LEGEND FOR SPECIFICATIONS
(SUBMIT SAMPLE TO CITY LANDSCAPE ARCHITECT FOR APPROVAL)
SPECIAL NOTE
CONTRACTOR SHALL SUPPLY A TOP LAYER OF 3" CLEAN "3/4" -MINUS" TOPSOIL TO ACHIEVE FINAL FINISH GRADE PRIOR TO "TOP
DRESSING" D.G.. ANY ROCK OR BOULDERS OVER 6" DIA. SHALL BE BURRIED A MINIMUM OF 12" DEEP OR REMOVED FROM THE SITE.
THE CLEAN TOPSOIL CAN EITHER BE GENERATED "ON-SITE" OR IMPORTED. THIS TOPSOIL SHOULD BE APPLIED
AFTER IRRIGATION AND DRAINAGE WORK HAS BEEN COMPLETED. QUALITY OF TOPSOIL SHALL BE APPROVED
BY THE CITY PRIOR TO INSTALLATION AND SHALL MEET ALL CITY STANDARDS.
TREE & PLANTING NOTES:
All trees shall be located as follows:
- A loin. of 25' from beginning of curb returns at any street intersection.
- 10' from light standard or utility enclosures.
- 5' from fire hydrants.
- A min, of Y from sidewalk edge, face of wall or back of curb.
- For trees shown to be planted within parkway
less than 6' wide, center tree accordingly.
- No tree shall be planted in parkway less than T wide.
- Provide appropriate size linear "Century" root barrier
for any tee planted with in 7' of hardscape element,
such as curbs, sidewalks or walls.
- Hold center of all shrubs or groundcover a min. of 24"
away from edge of paving (typ.)
SIZING LEGEND
0
1 GALLON d X 30" BOX
x 48" BOX
E7
5 GALLON x\LL36" BOX
x 54" BOX
15 GALLONx 42" BOX
X 60" BOX
°
x
24" BOX Indicates quantity
Indicates species
° Indicates palm
x B.T.H. as noted.
x Denotes trees that are to be tagged by the Landscape
Architect.
Concrete sidewalk - Per C.E. Plans
(L) Sight Line - Per C.E. Plans
Retaining condition per C.E. wall plans
�4 Perimeter wall per C.E. wall plans
(5 j Install 2" layer of 3/4" "Apache Sunset" fractured rock. Rock available from Southwest Boulder
& Stone (760) 342-5522. Provide Permaloe C1eanLine 1/8" x 4" aluminum header with mill
finish. Set flush with top of gravel and install per manufacture's specification.
See detail 6, sheet L-1
'Blasted Granite' landscape boulders from Southwest Boulder & Stone (760) 342-5522 Install per
�J boulder installation detail 3, sheet L-1. Numbers indicate boulder size in total cubic feet (10 total
- this plan).
svn°eoL Fractured Rock Top Coat: Install a 1" - 1 1/2" layer of'Mojave Gold' 3/8" fractured rock over
smooth finish grade as mulch/bark substitute after all planting. Submit sample to Landscape
Architect for approval prior to installation. Available from Southwest Boulder & Stone (760)
342-5522.
Street Lighting per C.E. plans
aCatch basin per C.E. plans
CITY OF FONTANA
CFD LANDSCAPE PLANS JR: 19962 LOT B1)
DRAWN BY: CYPRESS AVENUE AS SHOWN
(WEST SIDE - STA. 38+35 TO 49+00)
DESGNm DATE'PLAN G DERULS & NOTES
CHECKED BY: APPROVED BY: .511 17 5691. 2
DATE:
ENGINEER R.C.E. 51152 EXP. DATE 1®
J-4 1 T e s C A P e s
Landscape Architecture
and Planning
3190 B2 Airport Loop Drive
Costa Mesa, CA 92626
Richard Polharrus, License CA -$2782
(949) 644-9370 (714) 210-3140 FAX
rLI
E"I
U
t
O
®
U
F
M/
FLI
0
1>
U
~
�� VpNDSCq F
PLAN CHECK NO.
DATE 01/16/17
JOB #
16-026
1
OF 10
t
J
i
�� VpNDSCq F
PLAN CHECK NO.
DATE 01/16/17
JOB #
16-026
1
OF 10