INSTALLATION NOTE:
- CONTRACTOR TO RUN (15) REMAINING CONTROL WIRES
AND (1) COMMON WIRE (LABELED) TO THIS LOCATION
FOR FUTURE USAGE. PROVIDE 36" LOOP WITHIN AN / r
APPROVED LABELED VALVE BOX. 15 16 17 18 19 1, o
- CONTRACTOR TO CAP MAINLINE AT THIS LOCATION FOR \ / 14 I
FUTURE PHASE ON DUNCAN CANYON ROAD. LOCATE I I W
BENEATH APPROVED LABELED VALVE BOX.
.Y I W
a� 96 99,® 99.9 00,6
I Z
13
L—_ I U
— i CONTROLLER: 'C' STREETSCAPE
CONTRACTOR TO INSTALL A TORO SBW24SS5U-SHHR (24) STATIONS I '
II CONTROLLER W/ TORO'TRS' WIRED RAIN SENSOR. LOCATE CONTROLLER IN AN
\ APPROVED STAINLESS STEEL EDISON METER BOX ENCLOSURE PER CFD
STANDARDS. HAND HELD IRRIGATION RADIO CONTROLLER SHALL BE FULLY `/ 1
FUNCTIONAL AND TURNED OVER TO THE CITY OF FONTANA AT THE TIME OF 1
\ FINAL ACCEPTANCE. CONTRACTOR TO INSTALL A TORO SENTINEL EXTERNAL 1
ANTENNA ON THE TOP OF A POLE BY DAVIS INSTRUMENTS. SECURE THE POLE IT OF WORK
\ \ / TO THE SIDE OF CONTROLLER ENCLOSURE. INSTALL PER MANUFACTURER'S
\ \ / SPECIFICATIONS.
VERIFY LOCATIONS WITH EDISON AND THE CITY INSPECTOR PRIOR TO
PURCHASE OR INSTALLATION OF THE ENCLOSURE. SEE SITE ELECTRICAL I
�?\10 PLANS PRIOR TO STARTING JOB.
0
POINT OF CONNECTION: 'C' (POTABLE WATER)
1 1/2" WATER METER, REFER TO CIVIL PLANS. CONTRACTOR TO INSTALL A
2" WILKINS 375 XL SERIES REDUCED PRESSURE BACKFLOW PREVENTER W/
2" WYE STRAINER - LOCATE IN A LEMEUR VANDAL- RESISTANT STEEL MESH
ENCLOSURE. COORDINATE LOCATION WITH CITY INSPECTOR. (SCREEN
WITH SHRUBS)
RESIDUAL PRESSURE: 114.0 PSI
DESIGN PRESSURE: 62.8 PSI
MAXIMUM DEMAND: 19.6 GPM
t7 9z
Cz
M M L L
M
8 6-------- 9 ------------------------
------------------- �-
6------- 6 � I�� 163
I" 13.0 i" 12.9 I" 11.9 3054 SF
26 SF 2581 SF 2380) SP 1256 SP
i
SEE SHEETS L5 -L7 FOR IRRIGATION NOTES, LEGEND & DETAILS.
SCALE
1"-20'
IITIESCAPEI
Landscape Architecture
and Planning
3190 B2 Airport Loop Drive
Costa Mesa, CA 92626
Richard Polhamus, License CA -#2782
(849) 644-8370 (714) 210-3140 FAX
�� 1,ANDSCgPf
��R pQ0 A. PpIN4 '4?C
2782 "abs y%
v✓
CA -
PLAN CHECK NO.
DATE 03/13/17
JOB 16-026
L9
OF 14
Q
kn
a
W
_
V
d.d
I
�� 1,ANDSCgPf
��R pQ0 A. PpIN4 '4?C
2782 "abs y%
v✓
CA -
PLAN CHECK NO.
DATE 03/13/17
JOB 16-026
L9
OF 14