5686-7
0 o s NOTE: INSTALL BACKFLOW PREVENTER AS REQ. BY LOCAL CODES AND HEALTH DEPT. VERIFY LOCAL REQS. PRIOR TO INSTALLATION, SEE AS FLOW REDUCED PRESSURE APPROVED STRONGBOX SPECS. FOR MATERIALS N ENCLOSURE (PURPLE) BACKFLOW PREVENTER 90% COMPACTION REQUIRED II SAME SIZE AS BRASS NIPPLES (4" MIN. BALL VALVE -III LENGTH) VERIFY W/ (2) TOTAL LOCAL CODES BRASS "Y" SIZE —) 6 .... STRAINER W/ ) CONTROL WIRE SLEEVE - 60 MESH) -IIITYP.,- BRASS 90 ELL ITYP.) MONEL SCREEN �� SIZE PER PLAN INSTALL 8 BRASS PLUG ® ® OF FLOW METER SIZE) ® O AADJA PRESSURE -III- UNINTERRUPTED PIPE HDX DIAMETER III— YNTT EXISTING @ P.O.C. 'C' - SEE SHEET L-8 —III (— 5) FLOW METER II=1� 30" FG UNION (TYP.) FROM P.O.C.—AI-1 —I I1=111=111=111=1 1— -1 —I -" ` "' "' PVC MAINLINE I -III-III=IIIIII-III- � I -III = - -I 1=I -- -111= =1 = L= 1- 12"X12"X12" — I 12"X12"X12" CONCRETE — —III—III FLOOR DRAIN CONCRETE THRUST BLOCK THRUST 1 — — I I1 -1I I- — THRUST BLOCK USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL PVC TO PVC OR METAL TO PVC MALE PIPE THREADS EXISTING @ P.O.C. 'C'- SEE SHEET L-8 in REDUCED PRESSURE B.F. 10" CIRCULAR QUICK COUPLING VALVE. APPROVED VALVE BOX TOP OF VALVE SHALL BE (PURPLE) 2" BELOW VALVE BOX COVER 1/2" STAINLESS STEEL HOSE CLAMP. 3 REQUIRED 1" IN TURF AREAS 41SH GRADE 2" IN SHRUB AREAS PEA GRAVEL. 2 CUBIC FEET MIN. SCH40 90 DEGREE NOTE: PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX PVC SCH 40 ELL PVC SCH 80 NIPPLE (TYPICAL, LENGTH AS REQUIRED) 30 -INCH LINEAR LENGTH. OF WIRE, COILED WATER PROOF CONNECTION: RAIN BIRD SPUCE-1 (1 OF 2) VALVE BOX WITH COVER RAINBIRD VB-JMB (PURPLE) ID TAG: RAIN BIRD VID SERIES TOP OF MULCH - FINISH GRADE' CONTROL ZONE KR: SEE LEGEND FOR ASSEMBLY PVC LATERAI PVC SCH 40 MALE ADAPTER PVC SCH 80 NIPPLE, CLOSE (1 OF 3) PVC SCH 80 UNION FOR SERVICING ASSEMBLY PVC MAINLINE 3 -INCH MINIMUM DEPTH OF 3/4 -INCH WASHED GRAVEL BRICK (1 OF 4; PVC SCH 80 NIPPLE (2 -INCH LENGTH, HIDDEN) AND PVC SCH 40 ELL PVC SCH 40 TEE OR ELL EMU (11) CONTROL ZONE KIT SCHBO NIPPLE LENGTH AS REQUIRED BRICK SUPPORTS (THREE REQUIRED) )RESSURE LINE FRTING SCH40 90 DEGREE STREET ELL SCH80 NIPPLE LENGTH AS REQUIRED BACKFILL TRENCH PER SPECIFICATIONS I-III"'Illi III 1h III- III- CONCRETE THRUST II BLOCK, TYPICAL 1= I - MAINLINE PIPEav II 1III=III-III "—"' VIII '-111111— UNDISTURBED SOIL III 1 I 11- 45 DEGREE ELL —I n =1 III 1 =i I- 90 DEGREE ELL I 11= _-- CONCRETE THRUST BLOCK, TYPICAL MAINLINE PIPE -11 11 _® UNDISTURBED SOIL I I I- 1 BACK FILL TRENCH 90 DEGREE ELL PER SPECIFICATIONS SECTION VIEW - N.T.S. Call Underground Service Alert l�f at least 2 days before you dig Know what's below. 13 THRUST BLOCKS Call before you dig. NOTES: HARDSCAPING(SEE NOTE 4) 2) TYPICAL SLEEVING t _ 12" MAX. iTHR PVC MALE ADAPTOR TYP. TWO PLACES ELBOWS. SQE PER �••-- DRAWINGS. NOTES: 1. GATE VALVES 2 1/2- AND LARGER SHALL BE AWWA APPROVED AND HAVE A 2" SQUARE OPERATING NU` IN LIEU OF BRASS HANDWHEEL AND FLANGE CONNECTIONS IN UEU OF UNIONS. 2, GATE VALVES S" AND LARGER SHALL HAVE TRANSIT ADAPTERS. 3. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX 4. GATE VALVE SHALL BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE APPROVED 7) BALL/GATE VALVE PVC LATERAL PIPE ' SEE LEGEND NOTE: PLACE ALL AIR RELIEF ASSEMBLY AT HIGHEST SPOT IN THE FIELD FOR EACH SYSTEM. 12) AIR RELIEF VALVE ALL CONCRETE USED IN THRUST BLOCKS SHALL BE 470-C-2000. SUPPLY LINES 2 1/2" IN DIAMETER AND LARGER SHALL RECEIVE CONCRETE THRUST BLOCKING. THRUST BLOCKS SHALL BE A MINIMUM OF 1 CUBIC FT. OF CONCRETE. PIPE SHALL NOT BE ENCASED IN CONCRETE. ALL MAINLINES SHALL BE INSTALLED AND TESTED ACCORDING TO THE MANUFACTURER'S INSTALLATION SPECIFICATIONS. ALL TRENCH DEPTH AND WIDTH SHALL BE PER THE SPECIFICATIONS. WRAP PLASTIC FITTINGS IN CONTACT WITH CONCRETE USING BLACK PIPE TAPE. — TOP OF MULCH — 6—INCH ROUND VALVE BOX: RAIN BIRD VB-6RND (PURPLE) AIR RELIEF VALVE KIT: RAIN BIRD ARV050 AR VALVE KIT FINISH GRADE CAPE DRIPUNE TUBING: LEGEND FOR TYPE) 12" MIN, NON PRESSURE LATERAL LINE T�S�P1,17T�I� AS REQUIRED �-6" MIN. 18" MIN. 2" OF CLEAN EARTH II PRESSURE SUPPLY UNE NOTES: 1. BELOW PAVED AREAS A MINIMUM OF 6" LAYER OF CLEAN FILL SAND SHALL BE INSTALLED ABOVE AND BELOW PIPING. 2. PROVIDE MINIMUM COVER OF 24" ON PRESSURE SUPPLY UNES 3" AND LARGER. 3. WHEN USING RECLAIMED WATER , MAINTAIN MINIMUM 10' HORIZONTAL SEPARATION BETWEEN POTABLE AND RECLAIMED PRESSURE ONES. WHERE UNES CROSS, PROVIDE PVC SLEEVE FOR POTABLE UNE MINIMUM 5' EACH SIDE OF RECLAIMED WATER UNE TYPICAL TRENCHING VALVE BOX LABELING NOTE: HEAT BRAND ALL VALVE BOX COVERS IN 2" HIGH LETTERS PER EQUIPMENT LOCATED WITHIN VALVE BOXES. LABEL "GV" FOR ALL GATE VALVES LABEL "FM" FOR ALL FLOW MASTER VALVES LABEL "QCV" FOR ALL QUICK COUPLING VALVES LABEL "FV" FOR ALL FLUSH VALVES LABEL "MV" FOR ALL MASTER VALVES LABEL "AR" FOR ALL AIR RELIEF VALVES LABEL "VALVE STATION" FOR ALL CONTROLL VALVES 3 -INCH MINIMUM DEPTH OF 3/4 -INCH WASHED GRAVEL 00000 nonon 12" LEGEND - USE CARSON VALVE BOXES. 1. 10" DIAMETER CIRCULAR VALVE BOX. 2. EDGE OF LAWN, WALK, FENCE, CURB, ETC. 3. 14" x 19" RECTANGULAR VALVE BOX. 4. 20" x 30" RECTANGULAR VALVE BOX. NOTES A. CENTER VALVE BOX OVER VALVE TO FACILITATE SERVICING OF VALVE. B. SET VALVE BOXES 2" MAXIMUM ABOVE GRADE IN MULCH COVER OR GROUNDCOVER/SHRUB AREAS — SET FLUSH WITH FINISH GRADE IN TURF AREAS. C. SET VALVE BOX AND VALVE ASSEMBLY IN GROUND— COVER/SHRUB AREA WHERE POSSIBLE — INSTALL IN TURF ONLY IF THERE IS NO ADJACENT GROUND— COVER. D. SET VALVE BOXES PARALLEL TO ONE ANOTHER AND PERPENDICULAR TO EDGE. E. AVOID HEAVY COMPACTION OF SOIL AROUND VALVE BOXES TO PREVENT THEIR DEFORMATION/COLLAPSE. F. ALL BOXES TO BE PURPLE IN COLOR NOTE: CONTRACTOR TO USE PURPLE UDS WHEN NON—POTABLE WATER WATER SOURCE IS USED (SEE PLAN) 0 6" IRRIGATION BOX (PURPLE) OFINISH GRADE OR MULCH O 1/2" DRIP LATERAL LINE OFLUSH VALVE RAINBIRD MDCFPCAP/ MDCF COUP O5 PEA GRAVEL 00000000005 e OnOnOnOnOn® • • • APPROVED VALVE SIZE AS REQUIRE BRASS OR COPPER NIPPLE & UNION PVC MALE ADAPTER TYP. 2 (TWO) PLACES FINISH GRADE 12" MAX. 1" IN TURF AREAS 2" IN SHRUB AREAS O oD 0 BRICK ONE AT EACH PEA GRAVEL CORNER OF VALVE BOX PRESSURE MAIN LINE (PVC) ANGLE TO SPECIFIED CONTROL AND COMMON DEPTH WITH 45 -DEGREE WIRES. TAPE WIRES TO ELBOWS, SIZE PER MAIN LINE DRAWINGS, NOTES: 1. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX. 2. PLACE BOXES AT RIGHT ANGLES TO HARDSCAPE OR STRUCTURES. 3. PIPE UPSTREAM OF VALVE ASSEMBLY IS EQUAL IN DIAMETER TO DOWNSTREAM PIPING OF VALVE ASSEMBLY. IF NECESSARY, ADD REDUCE -BUSHING TO BRING PIPING DIAMETER TO VALVE SIZE 4. MASTER VALVES 4" AND LARGER TO BE PROVIDED WITH FLANGED CONNECTIONS IN LIEU OF UNIONS. EXISTING @ P.O.C. 'C'- SEE SHEET L-8 (D ROOT WATERING SYSTEM: RAIN BIRD RWS-B-C-1401 (INCLUDES RETAINER, 36"(91,4 CM) TUBE, 0.25 GPM (0,95 L/M) BUBBLER & INTEGRATED CHECK VALVE, 4"(10,2 CM) PURPLE GRATE, VERSATILE 5 SWING ASSEMBLY WITH 1/2"(1,3 CM) M NPT INLET) O BUBBLER: RAIN BIRD 1401 0.25 GPM (0,95 L/M) (INCLUDED) ® FINISH GRADE/TOP OF MULCH ® 4" (10,2 CM) PURPLE LOCKING GRATE - RWS-GRATE-P (INCLUDED) ® 12" (30,5 CM) SWING ASSEMBLY (INCLUDED) 7 6 8 © 1/2" (1,3 CM) MALE NPT INLET (INCLUDED) 9 O PVC SCH 40 TEE OR EL ® PVC OR POLYETHYLENE LATERAL PIPE O 4" (10,2 CM) WIDE X 36" (91,4 CM) LONG RIGID BASKET WEAVE CANISTER (INCLUDED) ffi ffi 10 OPTIONAL SOCK (RWS-SOCK) FOR SANDY SOILS NOTES: 11 TREE LOCATION 1. 4" (10,2 CM) GRATE IS ALSO AVAILABLE IN PURPLE (RWS-GRATE-P). 2. INSTALL PRODUCT SO THAT THE GRATE IS EVEN WITH FINISH GRADE OR TOP OF MULCH. 3. OPTIONAL SAND SOCK (RWS-SOCK) IS 34" (86,4 CM) IN LENGTH TO COVER MESH BASKET AREA. 4. WHEN INSTALLING IN EXTREMELY HARD OR CLAY SOILS, ADD 3/4" (1,9 CM) GRAVEL UNDER AND AROUND THE UNIT TO ALLOW FASTER WATER INFILTRATION AND ROOT PENETRATION. 5. ONCE RWS HAS BEEN INSTALLED FILL THE BASKET WITH PEA GRAVEL BEFORE LOCKING LID. 9 ROOT WATERING SYSTEM Downloadable CAO drawings and product specifications available at www.ezltoferolizing.coM3-0.asp :'Z0031 -C X Features Tank Capacity - Liquid: Approx. 2.5 Gal. (9.5 liters) Tank Capacity - Water Soluble Fertilizer: Up to 15 - 18 lbs. (6.8 - 8.2 kg) Minimum Flow Requirements: 2.5 gallons/hour (9.5 liters/hr.) Adjustable Feed Ratio Range: 15,000:1/Slow setting to 400:1/Fast setting Water Volume to Empty Tank: 37,500 gal (142 1<I)/Slow setting 1,000 gal (3:8 kl)/Fast setting Unit Dimensions (LWH): 21" x 8" x 11" (53cm x 20cm x 28cm) Valve Box Minimum (LWH): 24" x 13" x 16" (61 cm x 33cm x 41 cm) Approx. Weight: 11 lbs. (4.9 kg) Suggested Landscape Coverage under normal watering conditions*: 100% turf Up to 15,000 sq It (1,395 sq m) 75% turf/25% trees/shrubs/flowers Up to 22,500 sq ft (2,092 sq. m) 50% turf/50% trees/shrubs/flowers Up to 30,000 sq ft (2,790 sq m) *Assumes a refill frequency of 4-6 weeks and watering every other day. Turf requires more water and therefore increases refill frequency. This unit will service larger areas when filled more frequently. Fertilizer requirements may be reduced when used in conjunction with an organic bio -stimulant. EZ003-CX(Standard Capacity Model) Warranty: Five (5) years except under heavy pressure conditions or excessive temperature conditions where summer temperatures exceed 100° F (38° C). Heavy pressure conditions are when static line pressure exceeds 50 PSI (5.5 bars) See other detailed warranty and installation limitations at www.ezflonjection.com/resources/Warranty. Includes: Does Not Include: Bypass fitting, tubing and tubing clamps Irrigation coupling connector. An approved EZ-FLO connection Pressure relief valve - rated 150 PSI (10 bars) is the minimum required. An EZ-FLO ball valve connector (CBV) is Two (2) EZ Shutoff valves required for low flow conditions, sloped landscapes or when using viscous products, such as heavy organic bio -stimulants, to ensure proper proportioning. This system connects direct) to the irrigation piping after the back flow e o prevention device and the tankisdesi designed for use antler constant pressure. Ys Y 9 P P 9 sstre. P 9 P EZ -PLO's patented flow recess automatically adjusts to changes in water pressure and water flow without changing fittings. This product is designed to feed both sprinkler and drip irrigation zones for commercial, municipal, sports field, golf course, grower and residential applications. This system is designed for the delivery of products that are designated as non -hazardous. A code compliant back flow prevention device is required for installation. Installation must follow local and state plumbing codes. Unless otherwise specified, a pressure vacuum breaker is the minimum back flow prevention device required according to University of Southern California - Foundation for Cross Connection Control and Hydraulic Research. © 2016,:EZ-FLO Fertilizing Systems Phone (866) 393-5601 Fax (916) 652-5754 www.ezflofertilizing.com EXISTING @ P.O.C. 'C' - SEE SHEET L-8 15 FERTILIZER INJECTOR (EXISTING) 0 y WHITE BLUE • RED BLACK IRRIGATION CONTROLLER PURPLE PLASTIC VALVE BOX - (CARSON OR EQUAL) WITH PLASTIC INTEGRATED LOOKING LID. PLACE AT GRADE INTURF AREAS AND 3" ABOVE IN PLANT BED. PIG TAIL EXPANSION LOOP tMIN.24" LONG) BLACK EPDXY FILLED WATERPROOF CONNECTOR OR EQUAL CPIG TAIL EXPANSION LOOP (MIN.24" LONG) WATERPROOF ALL WIRE CONNECTIONS BLUE MASTER CONTROL VALVE -III LDIAMETER SAME AN BACKFILL SE SEE AS FLOW SPECS. FOR MATERIALS N —) I II I I� 90% COMPACTION REQUIRED II SAME SIZE AS PROVIDE 6" MIN. OF SAND -III FLOW METER BEDDING AND SHADDING SIZE —) 6 .... CONTROL WIRE SLEEVE - -IIITYP.,- MINIMUM DISTANCE DOWNSTREAM OF �� SIZE PER PLAN INSTALL _ OF FLOW METER SIZE) AADJA PRESSURE -III- UNINTERRUPTED PIPE HDX DIAMETER III— YNTT EXISTING @ P.O.C. 'C' - SEE SHEET L-8 —III (— 5) FLOW METER II=1� _ PRESSURE SUPPLY LINE • SLEEVE - SIZE TWICE DIAMETER PRESSURE SLJP UNE III—III—III—III_ RE LATERAL I_ UNE SLEEVE SIZE TWICE DIAMETER OF NON -PRESSURE LATERAL UNE NOTES: 1. ALL SLEEVES TO BE SCH 40 PVC. 2. EXTEND ALL SLEEVES 12" BEYOND EDGE OF HARDSCAPING AT BOTH ENDS. 3. ROUTE SLEEVING AROUND HANDICAP RAMPS. 4. PIPING UNDER PAVEMENT SUSCEPTIBLE TO TRAFFIC LOADS REFER TO CITY STANDARDS. (24" MIN. TO 36" MAX DEPTH TO TOP OF PIPE BELOW HARDSCAPE SURFACE. 2) TYPICAL SLEEVING t _ 12" MAX. iTHR PVC MALE ADAPTOR TYP. TWO PLACES ELBOWS. SQE PER �••-- DRAWINGS. NOTES: 1. GATE VALVES 2 1/2- AND LARGER SHALL BE AWWA APPROVED AND HAVE A 2" SQUARE OPERATING NU` IN LIEU OF BRASS HANDWHEEL AND FLANGE CONNECTIONS IN UEU OF UNIONS. 2, GATE VALVES S" AND LARGER SHALL HAVE TRANSIT ADAPTERS. 3. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX 4. GATE VALVE SHALL BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE APPROVED 7) BALL/GATE VALVE PVC LATERAL PIPE ' SEE LEGEND NOTE: PLACE ALL AIR RELIEF ASSEMBLY AT HIGHEST SPOT IN THE FIELD FOR EACH SYSTEM. 12) AIR RELIEF VALVE ALL CONCRETE USED IN THRUST BLOCKS SHALL BE 470-C-2000. SUPPLY LINES 2 1/2" IN DIAMETER AND LARGER SHALL RECEIVE CONCRETE THRUST BLOCKING. THRUST BLOCKS SHALL BE A MINIMUM OF 1 CUBIC FT. OF CONCRETE. PIPE SHALL NOT BE ENCASED IN CONCRETE. ALL MAINLINES SHALL BE INSTALLED AND TESTED ACCORDING TO THE MANUFACTURER'S INSTALLATION SPECIFICATIONS. ALL TRENCH DEPTH AND WIDTH SHALL BE PER THE SPECIFICATIONS. WRAP PLASTIC FITTINGS IN CONTACT WITH CONCRETE USING BLACK PIPE TAPE. — TOP OF MULCH — 6—INCH ROUND VALVE BOX: RAIN BIRD VB-6RND (PURPLE) AIR RELIEF VALVE KIT: RAIN BIRD ARV050 AR VALVE KIT FINISH GRADE CAPE DRIPUNE TUBING: LEGEND FOR TYPE) 12" MIN, NON PRESSURE LATERAL LINE T�S�P1,17T�I� AS REQUIRED �-6" MIN. 18" MIN. 2" OF CLEAN EARTH II PRESSURE SUPPLY UNE NOTES: 1. BELOW PAVED AREAS A MINIMUM OF 6" LAYER OF CLEAN FILL SAND SHALL BE INSTALLED ABOVE AND BELOW PIPING. 2. PROVIDE MINIMUM COVER OF 24" ON PRESSURE SUPPLY UNES 3" AND LARGER. 3. WHEN USING RECLAIMED WATER , MAINTAIN MINIMUM 10' HORIZONTAL SEPARATION BETWEEN POTABLE AND RECLAIMED PRESSURE ONES. WHERE UNES CROSS, PROVIDE PVC SLEEVE FOR POTABLE UNE MINIMUM 5' EACH SIDE OF RECLAIMED WATER UNE TYPICAL TRENCHING VALVE BOX LABELING NOTE: HEAT BRAND ALL VALVE BOX COVERS IN 2" HIGH LETTERS PER EQUIPMENT LOCATED WITHIN VALVE BOXES. LABEL "GV" FOR ALL GATE VALVES LABEL "FM" FOR ALL FLOW MASTER VALVES LABEL "QCV" FOR ALL QUICK COUPLING VALVES LABEL "FV" FOR ALL FLUSH VALVES LABEL "MV" FOR ALL MASTER VALVES LABEL "AR" FOR ALL AIR RELIEF VALVES LABEL "VALVE STATION" FOR ALL CONTROLL VALVES 3 -INCH MINIMUM DEPTH OF 3/4 -INCH WASHED GRAVEL 00000 nonon 12" LEGEND - USE CARSON VALVE BOXES. 1. 10" DIAMETER CIRCULAR VALVE BOX. 2. EDGE OF LAWN, WALK, FENCE, CURB, ETC. 3. 14" x 19" RECTANGULAR VALVE BOX. 4. 20" x 30" RECTANGULAR VALVE BOX. NOTES A. CENTER VALVE BOX OVER VALVE TO FACILITATE SERVICING OF VALVE. B. SET VALVE BOXES 2" MAXIMUM ABOVE GRADE IN MULCH COVER OR GROUNDCOVER/SHRUB AREAS — SET FLUSH WITH FINISH GRADE IN TURF AREAS. C. SET VALVE BOX AND VALVE ASSEMBLY IN GROUND— COVER/SHRUB AREA WHERE POSSIBLE — INSTALL IN TURF ONLY IF THERE IS NO ADJACENT GROUND— COVER. D. SET VALVE BOXES PARALLEL TO ONE ANOTHER AND PERPENDICULAR TO EDGE. E. AVOID HEAVY COMPACTION OF SOIL AROUND VALVE BOXES TO PREVENT THEIR DEFORMATION/COLLAPSE. F. ALL BOXES TO BE PURPLE IN COLOR NOTE: CONTRACTOR TO USE PURPLE UDS WHEN NON—POTABLE WATER WATER SOURCE IS USED (SEE PLAN) 0 6" IRRIGATION BOX (PURPLE) OFINISH GRADE OR MULCH O 1/2" DRIP LATERAL LINE OFLUSH VALVE RAINBIRD MDCFPCAP/ MDCF COUP O5 PEA GRAVEL 00000000005 e OnOnOnOnOn® • • • APPROVED VALVE SIZE AS REQUIRE BRASS OR COPPER NIPPLE & UNION PVC MALE ADAPTER TYP. 2 (TWO) PLACES FINISH GRADE 12" MAX. 1" IN TURF AREAS 2" IN SHRUB AREAS O oD 0 BRICK ONE AT EACH PEA GRAVEL CORNER OF VALVE BOX PRESSURE MAIN LINE (PVC) ANGLE TO SPECIFIED CONTROL AND COMMON DEPTH WITH 45 -DEGREE WIRES. TAPE WIRES TO ELBOWS, SIZE PER MAIN LINE DRAWINGS, NOTES: 1. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX. 2. PLACE BOXES AT RIGHT ANGLES TO HARDSCAPE OR STRUCTURES. 3. PIPE UPSTREAM OF VALVE ASSEMBLY IS EQUAL IN DIAMETER TO DOWNSTREAM PIPING OF VALVE ASSEMBLY. IF NECESSARY, ADD REDUCE -BUSHING TO BRING PIPING DIAMETER TO VALVE SIZE 4. MASTER VALVES 4" AND LARGER TO BE PROVIDED WITH FLANGED CONNECTIONS IN LIEU OF UNIONS. EXISTING @ P.O.C. 'C'- SEE SHEET L-8 (D ROOT WATERING SYSTEM: RAIN BIRD RWS-B-C-1401 (INCLUDES RETAINER, 36"(91,4 CM) TUBE, 0.25 GPM (0,95 L/M) BUBBLER & INTEGRATED CHECK VALVE, 4"(10,2 CM) PURPLE GRATE, VERSATILE 5 SWING ASSEMBLY WITH 1/2"(1,3 CM) M NPT INLET) O BUBBLER: RAIN BIRD 1401 0.25 GPM (0,95 L/M) (INCLUDED) ® FINISH GRADE/TOP OF MULCH ® 4" (10,2 CM) PURPLE LOCKING GRATE - RWS-GRATE-P (INCLUDED) ® 12" (30,5 CM) SWING ASSEMBLY (INCLUDED) 7 6 8 © 1/2" (1,3 CM) MALE NPT INLET (INCLUDED) 9 O PVC SCH 40 TEE OR EL ® PVC OR POLYETHYLENE LATERAL PIPE O 4" (10,2 CM) WIDE X 36" (91,4 CM) LONG RIGID BASKET WEAVE CANISTER (INCLUDED) ffi ffi 10 OPTIONAL SOCK (RWS-SOCK) FOR SANDY SOILS NOTES: 11 TREE LOCATION 1. 4" (10,2 CM) GRATE IS ALSO AVAILABLE IN PURPLE (RWS-GRATE-P). 2. INSTALL PRODUCT SO THAT THE GRATE IS EVEN WITH FINISH GRADE OR TOP OF MULCH. 3. OPTIONAL SAND SOCK (RWS-SOCK) IS 34" (86,4 CM) IN LENGTH TO COVER MESH BASKET AREA. 4. WHEN INSTALLING IN EXTREMELY HARD OR CLAY SOILS, ADD 3/4" (1,9 CM) GRAVEL UNDER AND AROUND THE UNIT TO ALLOW FASTER WATER INFILTRATION AND ROOT PENETRATION. 5. ONCE RWS HAS BEEN INSTALLED FILL THE BASKET WITH PEA GRAVEL BEFORE LOCKING LID. 9 ROOT WATERING SYSTEM Downloadable CAO drawings and product specifications available at www.ezltoferolizing.coM3-0.asp :'Z0031 -C X Features Tank Capacity - Liquid: Approx. 2.5 Gal. (9.5 liters) Tank Capacity - Water Soluble Fertilizer: Up to 15 - 18 lbs. (6.8 - 8.2 kg) Minimum Flow Requirements: 2.5 gallons/hour (9.5 liters/hr.) Adjustable Feed Ratio Range: 15,000:1/Slow setting to 400:1/Fast setting Water Volume to Empty Tank: 37,500 gal (142 1<I)/Slow setting 1,000 gal (3:8 kl)/Fast setting Unit Dimensions (LWH): 21" x 8" x 11" (53cm x 20cm x 28cm) Valve Box Minimum (LWH): 24" x 13" x 16" (61 cm x 33cm x 41 cm) Approx. Weight: 11 lbs. (4.9 kg) Suggested Landscape Coverage under normal watering conditions*: 100% turf Up to 15,000 sq It (1,395 sq m) 75% turf/25% trees/shrubs/flowers Up to 22,500 sq ft (2,092 sq. m) 50% turf/50% trees/shrubs/flowers Up to 30,000 sq ft (2,790 sq m) *Assumes a refill frequency of 4-6 weeks and watering every other day. Turf requires more water and therefore increases refill frequency. This unit will service larger areas when filled more frequently. Fertilizer requirements may be reduced when used in conjunction with an organic bio -stimulant. EZ003-CX(Standard Capacity Model) Warranty: Five (5) years except under heavy pressure conditions or excessive temperature conditions where summer temperatures exceed 100° F (38° C). Heavy pressure conditions are when static line pressure exceeds 50 PSI (5.5 bars) See other detailed warranty and installation limitations at www.ezflonjection.com/resources/Warranty. Includes: Does Not Include: Bypass fitting, tubing and tubing clamps Irrigation coupling connector. An approved EZ-FLO connection Pressure relief valve - rated 150 PSI (10 bars) is the minimum required. An EZ-FLO ball valve connector (CBV) is Two (2) EZ Shutoff valves required for low flow conditions, sloped landscapes or when using viscous products, such as heavy organic bio -stimulants, to ensure proper proportioning. This system connects direct) to the irrigation piping after the back flow e o prevention device and the tankisdesi designed for use antler constant pressure. Ys Y 9 P P 9 sstre. P 9 P EZ -PLO's patented flow recess automatically adjusts to changes in water pressure and water flow without changing fittings. This product is designed to feed both sprinkler and drip irrigation zones for commercial, municipal, sports field, golf course, grower and residential applications. This system is designed for the delivery of products that are designated as non -hazardous. A code compliant back flow prevention device is required for installation. Installation must follow local and state plumbing codes. Unless otherwise specified, a pressure vacuum breaker is the minimum back flow prevention device required according to University of Southern California - Foundation for Cross Connection Control and Hydraulic Research. © 2016,:EZ-FLO Fertilizing Systems Phone (866) 393-5601 Fax (916) 652-5754 www.ezflofertilizing.com EXISTING @ P.O.C. 'C' - SEE SHEET L-8 15 FERTILIZER INJECTOR (EXISTING) 0 y WHITE BLUE • RED BLACK IRRIGATION CONTROLLER PURPLE PLASTIC VALVE BOX - (CARSON OR EQUAL) WITH PLASTIC INTEGRATED LOOKING LID. PLACE AT GRADE INTURF AREAS AND 3" ABOVE IN PLANT BED. PIG TAIL EXPANSION LOOP tMIN.24" LONG) BLACK EPDXY FILLED WATERPROOF CONNECTOR OR EQUAL CPIG TAIL EXPANSION LOOP (MIN.24" LONG) WATERPROOF ALL WIRE CONNECTIONS BLUE MASTER CONTROL VALVE OD PVC SCH. 80 12" MAX. ID TAG: NUMBERED 18" MIN. po-p^o - -o v-eav c-" °- PEA GRAVEL. (MIN. 3 CU. FT.) PVC SCH. 60 NIPPLE, LENGTH AS REQUIRED TWO P CES• BRICK, ONE AT E PVC LATERAL UNE CORNER OF VALVI ANGLE TO SPECIFIED DEPTH WITH 45 -DEGREE ELBOWS SIZE PER DRAWINGS CONTROL AND COMMON PRESSURE MAIN LINE WIRES. TAPE WIRES TO PVC SCH. 40 TEE OR MAIN UNE ELBOW NOTES: 1. INSTALL CONTROL AND VALVES MINIMUM 2' APART, 2' FROM STRUCTURES OR HARDSCAPE IN SHRUB AREAS. 2. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX. 3. PLACE BOXES AT RIGHT ANGLES TO HARDSCAPE OR STRUCTURES. 4. PIPE UPSTREAM OF VALVE ASSEMBLY IS EQUAL IN DIAMETER TO .".,. To REMOTE CONTROL ON DOCUMENTS FOR 10) REMOTE CONTROL VALVE EZ-FLO FERTILIZING SYSTEM MODEL NUMBER - EZ003-CX 2.5 GALLON CAPACITY NOT TO SCALE I - FINISHED GRADE 2 -VALVE BOX &COVER 20"LX 16WX12It 3 - PROPORTIONING CAP WITH FEED ADJUSTMENT KNOB 4 - EZ -PLO SHUT OFF VALVES ,ATTH DISCONNECT WASHERS 5 - EZ -PLO MODEL FZ003-CX FERTILIZING SYSTEM 21"LX8"DX11"H 6 - FERTILIZER OUT CONNECT CLEAR TUBE TO GREEN CONNECTIONS ON PROPORTIONING CAP AND COUPLING 7 - WATER IN- CONNECT BLACK TUBE TO BLUE CONNECTIONS ON PROPORTIONING CAP AND COUPLING 8 - 1/4" TUBING CLAMP - BOTH THE GREEN AND BLUE COUPLING TUBING CONNECTIONS 9 - APPROVED BACKFILL 10 - PVC MALN LINE TO VALVE MANIFOLD 11 - EZ BALL VALVE COUPLING CONNECTOR - INSTALL ACCORDING TO WATER FLOW DIRECTION ARROW 12 - PEA GRAVEL (1 CU. FT.) 13 - PVC MAIN LINE FROM BACK FLOW PREVENTER 14 - PRESSURE RF.LEIF VALVE NOTE: ITEMS 3, 4, 5, 6, 7 AND 8 ARE INCLUDED WITH THE EZ-FLO SYSTEM. ITEM 11 IS PURCHASED SEPARATELY. Q 2012 EZ-FLO FERTILIZING SYSTEMS, INC. CITY OF FONTANA LANDSCAPE PLANS (TR: 19960 LOT'A; 19960-2 LASHOWN °�""" DUNCAN CANYON RD. mt& W. (SOUTH SIDE STA. 102+71 TO 115+80) IRRIGATION DETAILS, CALCS. & SCHED.CHUM W. APPROVED ar: T E C A P Landscape Architecture and Planning 3190 B2 Airport Loop Drive Costa Mesa, CA 92626 Richard Polhamus, Licence CA -J/2782 (949) 644-9370 (714) 210-3140 FAX 00 + H U O 0°1, O Z W Z® � Q" H Z 0 U -^SCO �i a Z� - v� U ^ ® ® s®� CN 0 �J �o VANDSCAPf POLKA Q��2T$� ? PLAN CHECK NO. LSPC 17-015 ®ATE 4/13/17 Jos 16-026 L6 7 OF 11 FLOW METER LDIAMETER SAME SEE AS FLOW METER SIZE DIAMETER SAME SIZE AS FLOW METER SIZE MINIMUM DISTANCE DOWNSTREAM OF UNINTERRUPTED PIPE I5X DIAMETER OF FLOW METER SIZE) MINIMUM DISTANCE UPSTREAM OF UNINTERRUPTED PIPE HDX DIAMETER OF FLOW METER SIZE) EXISTING @ P.O.C. 'C' - SEE SHEET L-8 5) FLOW METER OD PVC SCH. 80 12" MAX. ID TAG: NUMBERED 18" MIN. po-p^o - -o v-eav c-" °- PEA GRAVEL. (MIN. 3 CU. FT.) PVC SCH. 60 NIPPLE, LENGTH AS REQUIRED TWO P CES• BRICK, ONE AT E PVC LATERAL UNE CORNER OF VALVI ANGLE TO SPECIFIED DEPTH WITH 45 -DEGREE ELBOWS SIZE PER DRAWINGS CONTROL AND COMMON PRESSURE MAIN LINE WIRES. TAPE WIRES TO PVC SCH. 40 TEE OR MAIN UNE ELBOW NOTES: 1. INSTALL CONTROL AND VALVES MINIMUM 2' APART, 2' FROM STRUCTURES OR HARDSCAPE IN SHRUB AREAS. 2. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX. 3. PLACE BOXES AT RIGHT ANGLES TO HARDSCAPE OR STRUCTURES. 4. PIPE UPSTREAM OF VALVE ASSEMBLY IS EQUAL IN DIAMETER TO .".,. To REMOTE CONTROL ON DOCUMENTS FOR 10) REMOTE CONTROL VALVE EZ-FLO FERTILIZING SYSTEM MODEL NUMBER - EZ003-CX 2.5 GALLON CAPACITY NOT TO SCALE I - FINISHED GRADE 2 -VALVE BOX &COVER 20"LX 16WX12It 3 - PROPORTIONING CAP WITH FEED ADJUSTMENT KNOB 4 - EZ -PLO SHUT OFF VALVES ,ATTH DISCONNECT WASHERS 5 - EZ -PLO MODEL FZ003-CX FERTILIZING SYSTEM 21"LX8"DX11"H 6 - FERTILIZER OUT CONNECT CLEAR TUBE TO GREEN CONNECTIONS ON PROPORTIONING CAP AND COUPLING 7 - WATER IN- CONNECT BLACK TUBE TO BLUE CONNECTIONS ON PROPORTIONING CAP AND COUPLING 8 - 1/4" TUBING CLAMP - BOTH THE GREEN AND BLUE COUPLING TUBING CONNECTIONS 9 - APPROVED BACKFILL 10 - PVC MALN LINE TO VALVE MANIFOLD 11 - EZ BALL VALVE COUPLING CONNECTOR - INSTALL ACCORDING TO WATER FLOW DIRECTION ARROW 12 - PEA GRAVEL (1 CU. FT.) 13 - PVC MAIN LINE FROM BACK FLOW PREVENTER 14 - PRESSURE RF.LEIF VALVE NOTE: ITEMS 3, 4, 5, 6, 7 AND 8 ARE INCLUDED WITH THE EZ-FLO SYSTEM. ITEM 11 IS PURCHASED SEPARATELY. Q 2012 EZ-FLO FERTILIZING SYSTEMS, INC. CITY OF FONTANA LANDSCAPE PLANS (TR: 19960 LOT'A; 19960-2 LASHOWN °�""" DUNCAN CANYON RD. mt& W. (SOUTH SIDE STA. 102+71 TO 115+80) IRRIGATION DETAILS, CALCS. & SCHED.CHUM W. APPROVED ar: T E C A P Landscape Architecture and Planning 3190 B2 Airport Loop Drive Costa Mesa, CA 92626 Richard Polhamus, Licence CA -J/2782 (949) 644-9370 (714) 210-3140 FAX 00 + H U O 0°1, O Z W Z® � Q" H Z 0 U -^SCO �i a Z� - v� U ^ ® ® s®� CN 0 �J �o VANDSCAPf POLKA Q��2T$� ? PLAN CHECK NO. LSPC 17-015 ®ATE 4/13/17 Jos 16-026 L6 7 OF 11