HomeMy WebLinkAbout5686-2S I T E S C A P E S
Landscape Architecture
and Planning
3190 82 Airport Loop Drive
Costa Mesa, CA 92626
Richard Polhamus, Ucense CA -#2782
(949) 644-9370 (714) 210-3140 FAX
TREE OR PALM TRUNK
PLANTING G NOTES
g
SIDEWALK (WHERE OCCURS)
ROOTBALL
Z
e
15
d
®�Z
4-�1/i
ym� LODGE POLE
PIPE �P
WEED CONTROL
g a
GR
WHERE PERENNIAL WEEDS EXIST ON SITE AT THE BEGINNING OF WORK, CLEAN AND REMOVE
a
Y' �. 3• ;^'
oZ
THESE EXISTING WEEDS BY MOWING OR GRUBBING OFF ALL PLANT MATERIAL. UPON
lVl y l
e F
7 7 p� TREE TRUNK
p'
COMPLETION OF SOH. PREPARATION AND PLANTING OF ALL SPECIMEN TREES, BEGIN WEED
p). �J' p • ?
WONDERTIE
3" DIA. SCH. 80
PVC STAND PIPE
ABATEMENT PROGRAM BY APPLYING: 100 POUNDS OF A COMMERCIAL FERTILIZER, 46-0-0, PER
ACRE AND PER MANUFACTURER'S SPECIFICATIONS. WATER ALL AREAS FOUR (4) TIMES DAILY
NOT TWIST)
FOR
0w
FOURTEEN (14) CONSECUTIVE DAYS UNTIL WEED SEEDS HAVE GERMINATED. CEASE
p \i
\ PREVAILING WIND
0
°tl
PLANTER BACKFILL MIX
/
WATERING FOR THREE (3) DAYS. SPRAY A NON-SELECTIVE, NON -RESIDUAL, SYSTEMIC
O p DIRECTION
HERBICIDE TO ERADICATE GERMINATED WEEDS. LET THE WEEDS DIE WITHOUT IRRIGATION
`
—
COMPACTED SOIL
FOR A MINIMUM DEPTH OF 1/4"INCH BELOW THE SURFACE OF THE SOIL. IF STUBBORN AND
"WONDER TREE -TIE" - WRAP WIRE AROUND
RESIDUAL WEEDS (I.E. BERMUDA) SHOULD PERSIST ERADICATION PROCEDURE SHOULD BE
OUTSIDE OF STAKE. SECURE TO STAKEw
3 DIA. CORRUGATED
REPEATED. THE TYPE OF WEEDS THAT EXIST SHOULD BE IDENTIFIED AND COORDINATED WITH
PER MANUFACTURE'S RECOMMENDATION
a PLACE BELOW BRANCHING YOKE OF TREE
A.D.S. PERFORATED
AN APPROVED LICENSED PEST CONTROL ADVISOR TO ENSURE COMPATIBILITY WITH CHEMICAL
RAIN PIPE W/ DRAIN
- — - - - - - - -- -
AND SEASON OF APPLICATION. DO NOT USE MATERIAL OR METHOD THAT WOULD ADVERSELY
(2) 3" DIA x 10' LONG LODGEPOLE PINE STAKES:
1 1 /2x ROOTBALL SIZE SOCK LAID ® BASE
OF ROOTBALL
EFFECT NEW PLANTINGS, SLOPE STABILIZATION OR HYDROSEEDING.
LOCATE OUTSIDE OF ROOTBALL
'SOIL TEST
ARBOR GUARD IN TURF AREAS
AFTER ALL SOIL HAS BEEN IMPORTED TO THE SITE AND ROUGH GRADING COMPLETED BUT
SEr TOP OF ROOTBALL 8" ABOVE FINISH
S E C T I 0 N
PRIOR TO SOIL PREPARATION, SEVERAL SOIL SAMPLES SHALL BE TAKEN BY THE SOILS LABORATORY
s GRADE INSTALL 4" LAYER OF NITROLIZFO
® W000 CHIP MULCH.
OR BY THE CONTRACTOR AT THEIR INSTRUCTION AND A REPORT/RECOMENDATION
9O% COMPACTED SOIL
PRODUCED. THE CONTRACTOR SHALL FURNISH A COPY OF THE SOIL TEST FOR
DEEP ROOT BARRIER
AGRICULTURAL SUITABILITY AND FERTILITY (PREPARED BY A CALIFORNIA ASSOCIATION OF
IF WITHIN 5' OF ANY
— — — TREE OR PALM TRUNK
AGRICULTURAL LABORATORIES MEMBER) TO THE CONTRACTING OFFICER AND THE CITIES INSPECTOR,
FG HARDSCAPE (SEE DETAIL)
/ — — —
UPON REVIEWING THE SOILS REPORT THE ARCHITECT MAY MAKE SPECIES
SUBSTITUTIONS TO THE PLANT LIST.
WATER BASIN �ROOTBALL
ONCE PLANT IS
R LANDSCAPE AITCH DIRECTION
�• ° .• v a e. ESTABLISHED ER
SOIL PREPARATION
0 I 1 :. PLANT PIT DRAIN WHEN REQUIRED
e (PER SEPARATE DETAIL)
Ill
3" DIA. SCH. 80
I I PIPE TAD PIPE W/
NOTES: APPROX. BOULDER FOOTPRINT SIZES
MACHINE ROTOTILL THE FOLLOWING AMENDMENTS INTO THE SOIL AT RATES INDICATED PER
g EI I
I I
O1 BURY A MINIMUM OF 1/3 DEPTH
2? 2' X 2' X 2'= 8 CU FT
CU/FT
1000 SF: (THESE RATES ARE FOR BID PURPOSES ONLY, ACTUAL RATES TO CORRESPOND TO
CONTRA�C SOILS
oa f-- GRO POWER FERTILIZER TABLETS.
APPLICATION RATES PER TABLE. REFER
I I LIMITS Of PLANT PIT
J
OF BOULDER SIZE.
S®RS
NITROGENSTOABILIZED SAWDUST
I I
?° 1 % TO PLANTING NOTES.
\ — — —
3" DIA. CORRUGATED A.D.S. PERFORATED
�- — — — -�
,
® BOULDER - SEE 6 ON SHEET l3' 3 X 3 X 3= 27 CU/FT
150 LBS. GYPSUM
RAIN PIPE W/ DRAIN SOCK LAID ®
Ll FOR SPECIFICAIIVN
125 LBS STANDARD FERTILIZER
BACKFILL MIX PER SPECS.
IS
BASE OF ROOTBALL
® SCARRED OR BROKEN BOULDERS 4' X 4' X 4' = 64 CU/FI
N EXTIVE
EXCAVATE TOCORRE�CTT HEIGHT
PLAN VIEW
SHALL NOT BE PERMITTED.
DEEP ROOT BARRIERS
FOR PLANTING. SCARIFY BOTTOM
TO ENSURE ADEQUATE DRAINAGE
®PLACE PER PLANS AND
ALL TREES WITHIN 7 FEET OF ANY PERMANENT HARDSCAPE ELEMENT SUCH AS CONCRETE
FOR HEALTHY GROWTH OF PLANT.
LANDSCAPE ARCHITECT'S DIRECTION
WALKS, WALLS OR BUILDINGS SHALL BE PLANTED WITH AN APPROPRIATE SIZED ROOT
BARRIER (UNLESS OTHERWISE NOTED ON PLANS). ROOT BARRIER TO BE LINEAR PANEL (TYP.)
ROOTBALL SCHEDULE OF PIT EXCAVATION
SEE DETAIL.
6GAL -X-6"
15 GAL - x ® 9"
TOP DRESSING (FUEL MODIFICATION AREA)
24" BOX & LARGER — X ® 12" MAX.
ALL SHRUB AND GROUNDCOVER AREAS SHALL BE TOP DRESSED WITH A V-1/2" LAYER OF DECOMPOSED
GRANITENRACTURED ROCK. SEE CONSTRUCTION LEGEND Q FOR SPECIFICATIONS
(SUBMIT SAMPLE TO CITY LANDSCAPE ARCHITECT FOR APPROVAL)
I TREE STAKING
O PIT DRAIN DETAIL
O BOULDER INSTALLATION DETAIL
SPECIAL NOTE
CONTRACTOR SHALL SUPPLY A TOP LAYER OF 3" CLEAN "3/4" -MINUS" TOPSOIL TO ACHIEVE FINAL FINISH GRADE PRIOR TO "TOP
DRESSING" D.G.. ANY ROCK OR BOULDERS OVER 6" DIA. SHALL BE BURRIED A MINIMUM OF 12" DEEP OR REMOVED FROM THE SITE.
THE CLEAN TOPSOIL CAN EITHER BE GENERATED "ON-SITE" OR IMPORTED. THIS TOPSOIL SHOULD BE APPLIED
AFTER IRRIGATION AND DRAINAGE WORK HAS BEEN COMPLETED. QUALITY OF TOPSOIL SHALL BE APPROVED
BY THE CITY PRIOR TO INSTALLATION AND SHALL MEET ALL CITY STANDARDS.
TREE & PLANTING NOTES:
HOLD ROOTBALL ABOVE ULTIMATE
All trees shall be located as follows:
FINISHED GRADE:
2 w
-I 1" FOR 1 GAL
1/2- R. (TYP.) WO
- A min. of 25' from beginning of curb returns at any street intersection.
L --I 2" FOR 5 & 15 GAL
FRACTURED
O O
1 4 ¢
- 10' from light standard or utility enclosures.
=TIIITIT IT — ROCK
LAYER O
Z
II PER SPECIFICATIONS
o-L�LI=1I1=111= ".
r
I I -
ISI • ° .:
.A
- 5' from fire hydrants.
OF O L— •° : :., :.� 1�
W o -ITIZ :.®:' GRID POWER FERTILIZER TABLETS.
•• .:. R?Tri:•isc::?2-1. ?sfxKrc:?::kSE 7z^:_:]y:.e.:7`::ay:
'
- A min, of 3 from sidewalk edge, face of wall or back of curb.
SECTION
-�' - APPLICATION RATES
II III '%'' ' -
PER TABLE.
To V` ' '' '
5 GRAM AGRIFORM
°
' '% ` REFER TO SPECS.
=ill= .. r,•,;...;
"' °
rn
- For trees shown to be planted within parkway
TABLETS SEE SPECS.-
"
_ _ - _ _ -�
ll- - - - BACKFILL MIX PER
"II
• ' "• ' —
less than 6' wide, center tree accordingly.
1 DEEP DG MULCH LAYER
,IIHIHIhIIE II III III.II
NOTES.
e
- No tree shall be planted in parkway less than 4 wide.
° °q o° TILLED & AMENDED PLANTING
BED PER SOIL TEST
MIN•
3
- Provide appropriate size linear "Century" root barrier
.
NATURAL SUBGRADE
6"
for any tree planted with in 7' of hardscape element,
such as curbs, sidewalks or walls.
O1 FINISH GRADE
Hold center of allshrubs of a min. of 24"
F
HOLD ROOTBALL ABOVE ULTIMATE
FINISHED GRADE:
2O CONCRETE CURB - NATURAL COLOR CONCRETE
podrover
from edge
awaypaving
of
GROUNDCOVER PLANTS C3JP G9
�
FINISH
GRADE
1" FOR 1 GAL
2" FOR 5 & 15 GAL
O
SEE PLANTING PLANS
FRACTURED ROCK LAYER PER 7
O
3 (1) #3 REBAR -CONTINUOUS
SIZING LEGEND
FOR SPACING \
—
UR
1 DEEP DG MULCH
LAYER.
0 =I__ _
iii
.' -
SPECIFICATIONS
TEMPORARY 2" HIGH WATER
O FRACTURED ROCK TOP COAT O
o o n o n
e 1 GALLON ® 30 BOX 48 BOX
x x x
\
°
W : •�:° 11-
BASIN. REMOVE ONCE PLANT IS
ESTABLISHED
GRD POWER FERTILIZER TABLETS.
x 5 GALLON x 36" BOX X 54" BOX
PLAN °
TI •; :.`� SII_
T .; a+ .., .,},.. •+`a; rr. 6 •
''' =I
-
APPLICATION RATES PER TABLE.
0 0 r+ 0 rt
8 15 GALLON 0 42 BOX 60 BOX
REFER TO SPECS.
=III -I I L. I �I I I: I I I I=III Tim I
BACKFILL MIX PER NOTES.
� Indicates quantity X Indicates palm
o 24 BOX Indicates
s"
species B.T.H. as noted.
MIN.
* Denotes trees that are to be tagged by the Landscape Architect.
CONSTRUCTION SCHEDULE
4 o
GROUNDCOVER PLANTING
N ING
o SHRUB PLANTING
6 CONCRETE HEADER
0
Concrete sidewalk - Per C.E. Plans
STORM DRAIN/
UNDERGROUND UTILITIES
Sight Line -Per C.E. Plans
6" 2 6"
NOTES:
SEE NOTE 3
1 MIN. IAccessible
curb depression - Per C.E. Plans
A. POSITION BARRIER AS
5 I I
., ;. . _ ...
CLOSE TO CURB OR
SIDEWALK AS POS
Perimeter wall C.E.
Pitll & pilaster r p r e11 wa plans
. --
•......
-' •
° .;
Z °
cw ''
SHALLD ROOTPROTECTORS
TOWARDS THE TREE.
B. TOP OF BARRIER SHALL
5 1 2 3 6
Install 2" layer of 3/4" "Apache Sunset" fractured rock. Rock available from Southwest Boulder
5 p
& Stone (760) 342-5522. Provide Permaloc C1eanLine 1/8" x 4" aluminum header with mill
finish. Set flush with top of gravel and install per manufacture's specification.
W
SIDEWALK
UTILI
_,%
-0
3
to 3
BE 1 " ABOVE FINISHED
See detail 9, sheet L-1
4 • , a
— 4
GRADE.
-FLUSH
a�
Blasted Granite landscape boulders from Southwest Boulder & Stone (760) 342-5522 Install per
CURB AND GUTTER-----w
METE R
11 p g' \ \
\
TYP. TYP. -
C. LENGTH OF ROOT BARRIER
SHALL BE EQUAL TO
THE ULTIMATE DRIPLINE OF
r o D o o
°I N
�'
boulder installation detail 3, sheet L-1. Numbers indicate boulder size in total cubic feet 10 total
-this plan).
THE PARTICULAR TREE, OR
10' MAX.
� a i ` � /` a a
SM Fractured Rock Top Coat: Install a 1" - 1 1/2" layer of 'Mojave Gold' 3/8" fractured
UNDERGROUND STRUCTURE
i
rock over
CATCH BASIN
.'
/ \"�
LEGEND:P
smooth finish grade as mulch/bark Substitute after all planting. Submit sample to Landscape
g p p
TRANSFORMER VAULT.
\.
Architect for approval prior to installation. Available from Southwest Boulder & Stone (760)
— — — — — — — —
— II
O CONCRETE CURB OR
342-5522
SIDEWALK
A '
/ •° •� .. �•,•®' • I \
L.—�---' --= --- --"—��
I I\
I I \
HARDSCAPE
FINISHED GRADE
8 APPROVED ROOT CONTROL
BARRIER
® 3/4" TO 1 1/2" GRAVEL
4
g Street Lights per C.E. laps
1% 1T
9 Driveway Apron per C.E. plans
DRIVE O \10
I APPROACH I S'L'
y\
Z
� =
CURB AND GUTTER
I I
5' I 5' 10' 11 p' I
I j
OR CRUSHED ROCK
MIN "'III MIN fff MIN yyylll MIN tttFFF
I I
I I �
TREE
DRIP LINE TREE
CENTER OF T
-
10 Concrete Header - See detail 6, sheet L-1.
I 4 6 I 7
l
PARKWAY WIDTH
11 Hydrant location Per C.E. plans
5
I I
1 FINISH GRADE OF ADJACENT PLANTING
O
NOTES:
MIN
I I
I I /
ROOT BARRIER IS TO BE 18"
LINEAR BARRIER UB 18-2
WHEN ADJACENT TO WALK
®PERMALOCK SPLICING STAKE/LINE STAKE, INSTALL PER
1. TREE SPACING SHALL CONFORM TO PLANS APPROVED BY
I I
/
OR HARDSCAPE OR 24"
MANUFACTURER'S SPECIFICATIONS.
THE CITY ENGINEER AND FUEL MODIFICATION PLAN.
2. ALL TREES IN THE R.O.W. ARE SUBJECT TO LINE.OF.SIGHT
r--a.—ems �T,—• :.,
\ ` t ..a:.; I
'' ' •
' •
LINEAR BARRIER
UB 24-2 WHEN ADJACENT
®PERMALOCK 1/8" x 4" ML. FINISH ALUMINUM EDGING. NATURAL
ALUMINUM COLOR. INSTALL PER MANUFACTURER'S SPECIFICATIONS.
CRITERIA AS APPROVED BY TRAFFIC ENGINEER.
\ /
To CURB
®COMPACTED NATIVE SUB -GRADE
�,
G
3. AT ALL LOCAL RESIDENTIAL INTERSECTIONS THE FIRST TWO
AVAILABLE FROM:
CENTURY PRODUCTS
® DECORATIVE ROCK MULCH PER PLAN - DEPTH VARIES 70
PARKWAY TREES AT ALL APPROACHES TO BE PLACED BEHIND SIDEWALK.
1
1144 N. GROVE ST.
4. MAINTAIN 10 FEET FROM CENTER OF STREET TO EDGE
ANAHEIM, CA 92806
O2„ LAYER FRACTURED ROCK 5O
OF ALL UNDERGROUND FACILITIES.
ALIGN W/ ALIGN W/
714
( ) 632-7083
CITY OF FONTANA
DRIPLINE DRIPLINE
Call Underground Service Alert 5. MAINTAIN 10 FEET FROM ALL STREET LIGHTS, UTILITIES
OR OR
PER MFR. PER MFR.
LANDSCAPE PLANS (TR:19960LOT'A; 19960-2LOT'B')
STRUCTURES AND VALVE BOXES.
® at least 2 days
OF TREE
SPEC. SPEC.
DRAW ”' DUNCAN CANYON RD. e�
AS SHOWN
(SOUTH SIDE STA. 102+71 TO 115+80)
o before you digDESOMerc:
Knoww�harsb®o .. 07 TREE PLACEMENT
m PLANTING DETAILS NOTES &LEGEND
O ROOT BARRIER
OPE LOC ALUMINUM HEADER
Cali before you dig.
owiE 5686
P. 041E 11
S I T E S C A P E S
Landscape Architecture
and Planning
3190 82 Airport Loop Drive
Costa Mesa, CA 92626
Richard Polhamus, Ucense CA -#2782
(949) 644-9370 (714) 210-3140 FAX
�� VANDSCgpf
ti� d
PLAN CHECK NO.
LSPC 17-015
DATE 4/13/17
JOB 16-026
1
2 OF 11
~
�
Z
e
��p
d
®�Z
4-�1/i
��0UCN
®
c�D
oZ
lVl y l
^ 1
�� VANDSCgpf
ti� d
PLAN CHECK NO.
LSPC 17-015
DATE 4/13/17
JOB 16-026
1
2 OF 11