Loading...
HomeMy WebLinkAbout5685REF-9j at least 2 days o before you dig Knaw. whars below.. Call before you dig. .r - 7 A -5 . . A-4 A-br. _ ------------- ME&GER TF -5T POG II&II ELEOTfi?ICAL P.O.G. 5TA 2"T+00 A6AVE SCE POG FOR ELEOTRIGAL SERVICE LOCATE 50E STUB, EXTEND TO NEW METER LOCATION. PROVIDE PULL BOX, CONDUIT # WIRE IF NEOE55ARY REOUIRES SCE INSPECTION ELECTRICAL METER iADDRE55 16237 AGAVE AVE. (STA! GONM I T $ WIRE LE&ENE7 PROVIDE BLACK WIRE FOR PHASE "All PROVIDE RED WIRE FOR PHASE 11511 ALL CIRCUITS TO HAVE SEPARATE NEUTRALS ALL CIRCUITS TO BE 0 UNLESS OTHERINI5E NOTED Q 2#6 4 1 #6 E/6 - 5/4 Ila. 2#IO +s 1 010 E/6 - 112"a. TYPICAL IN SHADE 5TRUGTUR -5 • p` PVC, OONPUIT VV AIRM A5 SHOWN TO PANEL B CIRCUIT PIMI&NATION 1 GONDU 17 15 5HOINN D I ARAM AAI GALLY FOR GLAIR I TY AND 15 NOT INTENDED TO BE FREG15E IN THE FLAGEMENT. GONTRAGTOR SHALL GOORDINATE CONDUIT INSTALLATION WITH OTHER TRADES TO AVIOD GONFLIGT GONDU 1 T SHALL BE A MINIMUM OF 5' FROM GENTER LINE OF TREES GENERAL. ONi UNION NOTES I. PROVIDE ALL MATERIALS AND LABOR AS REGiUIRED TO ACHIEVE A COMPLETE AND OPERA7I146 SYSTEM. Z. COORDINATE AND OBTAIN APPROVALS FROM ALL RESPECTIVE UTILITY COMPANIES AS REQUIRED FOR A COMPLETE AND OPERATING INSTALLATION. O S. INSTALL RACEWAY SYSTEMS ASF LLOWS: a. USE P.V.C. SCH 40 CONDUIT UNDER6ROUND WITH CODE SIZED GROUND. 4. ALL NEW WIRING SHALL BE STRANDED COPPER TYPE "THHN/THWN" #10 AVi6. - U.O.N.. 5. ALL METER PEDESTAL LOCATIONS SHALL BE VERIFIED WITH LAN750APE ARCHITECTIS DRAWIN55 AS WELL AS EQUIPMENT SUPPLIER R.EQUIREMEN75 PRIOR TO ANY ROUGH -IN WORK. b. THESE PRAININC75 ARE DIA6RAMMATIC AND REPRESENT THE INTENT OF EQUIPMENT, DEVICES, ETC.. TO BE CONNECTED AND THE CIRCUITS TO WHICH THEY ARE TO BE CONNECTED TO. CONTRACTOR SHALL INSTALL ALL MATERIALS AS R,EOUIRED FOR A COMPLETE AND OPERATING 5Y5TEM. ?, ALL EXTERIOR EQUIPMENT SHALL BE U.L. LISTED FOR WET LOCATIONS. 5. ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK IN STRICT ACCORDANCE WITH ALL LOCAL AND NATIONAL GOVERNING CODES. ci. ALL EQUIPMENT SHALL BE NEW AND BEAR A "UL LABEL U.O.N.. 10. ELECTRICAL CONTRACTOR SHALL SECURE AND PAY FOR ALL NECE55ARY BUILDING PERMITS. 11. COMPLETE ELECTRICAL INSTALLATION SHALL BE GUARANTEED IN WRITING FOR A PERIOD OF (1) YEAR - U.O.N.. 12. ELECTRICAL CONTRACTOR SHALL VISIT SITE PRIOR TO BID DATE, TO VERIFY ALL. EXI5TING CONDITIONS TO BE ENCOUNTERED IN THE INSTALLATION OF ALL NEW EQUIPMENT ETC.. EXACT INSTALLATION METHOD AND REQUIREMENTS SHALL BE VERIFIED AND DETERMINED PRIOR TO BID DATE. CONTRACTOR SHALL IMMEDIATELY NOTIFY THI5 ENGINEER OF ANY REWIRED MODIFICATIONS WHICH ARE NOT SHOWN ON THESE DRAWINGS. SUBMITTAL OF BID INDICATES CONTRACTOR 15 COGNIZANT OF ALL JOB SITE OONDITION5 AND NORK TO BE PERFORMED. 15, ALL EQUIPMENT, ELECTRICAL CHARACTERISTICS, LOCATIONS, AND CONNECTION REQUIREMENT5 SHALL BE VERIFIED PRIOR TO ANY ROUPH-I`N NORK. 14. ELECTRICAL CONTRACTOR SHALL FURNISH THE FOLLOWIN6 SHOP DRAWINGS FOR PRIOR APPROVAL: a. ALL ELECTRICAL SERVICE EQUIPMENT 4 PULL BOXES. THESE ITEMS SHALL BE APPROVED BY THE OWNERS AUTHORIZED REPRESENTATIVE PRIOR TO ANY COMMENCEMENT OF PLACIN6 ORDERS OR PERFORMING ANY ROUGH -IN NORK. 15. COMPLETE ELECTRICAL 5Y5TEM SHALL BE GROUNDED IN ACCORDANCE WITH THE PRESENTLY ADOPTED EDITION OF THE N.E.C., ART. 250. I(o. PROVIDE THE ONNER AND THI5 ENGINEER WITH ONE SET OF ELECTRICAL "A5-5UILT5" AT THE COMPLETION OF JOB. I7. TRENCHES SHALL BE DEEP ENOUGH TO ALLOW FOR 24" OF COMER OVER THE CONDUITS. Ig, BACKFILL OF TRENCHES UNDER AREAS WHERE ASPHALT, CONCRETE OR VEHICULAR PAVING WILL BE PLACED, SHALL BE COMPACTED BY THE FOLLOWING MEANS: PROPERLY M015TEN SOIL, PLACE INTO TRENCHES 1N LIF75 OF 5 11, MAKE THREE (5) PASSES KITH A "STOMPER" TYPE COMPACTION DEVICE, REPEAT TO TOP OF TRENCH. TRENCHES SHALL ACHIEVE c15% RELATIVE COMPACTION. va WEST COA5T DESIGN GROUP ELECTRICAL d 1-161-ITING ENGINEERS 266"12 PA51E0' BRILLO, SUITE 200 5AN JUAN CAPI5TRANO, CA 1`12615 61441) 5-1000 ALL WIRING SHALL BE INSTALLED IN A METHOD THAT UPON COMPLETION THE SYSTEM 15 FREE FROM SHORT CIRCUITS AND 6ROUND5 (OTHER THAN REQUIRED 6ROUNAIN6). THE CONTRACTOR SHALL PROVIDE A '°ME66ER" INSULATION TEST (IN THE PRESENCE OF THE CITY REPRESENTATIVE) WHICH APPLIES A MINIMUM OF 500 VOLTS D.C. EACH CIRCUIT SHALL MEET THE REQUIREMENT5 FOR INSULATION RESISTANCE. THE TEST SHALL BE PERFORMED AFTER WIRING HAS BEEN INSTALLED IN THE CONDUIT, 15 SPLICED AND CONTINOU5 FROM PANEL TO TEND OF RUN FOR EACH WIRING SYSTEM (REMOVE RUSES IN EASE OF POLE FOR DURATION OF TEST). LOW AND HIGH VOLTAGE CIRCUITS SHALL COMPLY WITH THE FOLLOWING MINIMUM REQUIREMENTS FOR INSULATION RESISTANCE: CIRCUITS OF #4 OR SMALLER Y41RE5 1,000,000 OHMS CIRCUITS OF #2 OR LAR&ER WIRE5 - 500,000 OHMS SCALE 1 "=10° SHEET KEY I I CHK DATE 02/27/17 ESE I�yyIalI ;q{ol' ,j� I I�Wti rrrry i`7riJ LIMY °"41 fiEeee4eee_eeeeee6e ��� Ilul rrrrrrrrlrYlr�iri111r �� E1. 1 a OF 17 w � eeeeeeee mil EtlellelkVl���'l',s. �Will oe rrarrrrrrr_r ® U e , � o W d W � I H eeeeeeeee�� S I T ESCAP IG Landscape Architecture and Planning 3190 e2 Airport Loop Oriv®.. Costo Mesa. CA 92025 Richard Polhomus, License CA—#27d2 (20) 644-9370 (714) 210-3140 FAX N®. REVISION A E11028 a 06/30/17 DWN CHK DATE 02/27/17 JOB 16-033 E1. 1 a OF 17 w z 0 L) U z U W ry W d W H E11028 a 06/30/17 DWN CHK DATE 02/27/17 JOB 16-033 E1. 1 9 OF 17