HomeMy WebLinkAbout5685-14cc
I( 1
z
SECTION
)GE POLE
E TRUNK
iNDER TIE
NOT TWIST)
AROUND
STAKE
TION
F TREE
)LE PINE STAKES:
FINISH
ITROUZED
ANT IS
,.H DIRECTION
REFER
5GAL –X=6"
15 GAL – XB"
24" BOX & LARGER – X = 12" MAX.
TREE STAKING
5 GRAM AGRIFORM
TABLETS SEE SPECS.
2" DEEP ROCK/MULCH LAYER
°•..... '... . •..:::�............::?:A i^r�:::.::..... :;�{::• •rye:: r.;Fr.;k;:::• •:: •: •:..:.
f
.0a 10 /6 TILLED & AMENDED PLANTING
� / ° /�% BED PER SOIL TEST
NATURAL SUBGRADE
F G
GROUNDCOVER PLANTS �pJ
SEE PLANTING PLANS
FOR SPACING
2" DEEP ROCK/MULCH
LAYER.
PLAN
STORM DRAIN/
UNDERGROUND UTILITIES R
SEE NOTE 3
5
i
—..—. — .—. — — — ---
SIDEWALK —SIDEWALK UTILI
PC
TI
Q
CURB AND GUTTER METER
10' 5'
TYP. TYP,
CATCH BASIN TRUCTURE
— UNDERGROUND S
TRANSFORMER VAULT.
.— .— — — — --
SIDEWALK 1 w
DRIVE S. L.ffiO \1ol
APPROACH Py_ _
0
a
CURB AND GUTTER
MIN MIN MIN MIN
5'
NOTES: MIN
1. TREE SPACING SHALL CONFORM TO PLANS APPROVED BY
THE CITY ENGINEER AND FUEL MODIFICATION PLAN.
2. ALL TREES IN THE R.O.W. ARE SUBJECT TO LINE.OF.SIGHT
CRITERIA AS APPROVED BY TRAFFIC ENGINEER.
3. AT ALL LOCAL RESIDENTIAL INTERSECTIONS THE FIRST TWO
PARKWAY TREES AT ALL APPROACHES TO BE PLACED BEHIND SIDEWALK.
4. MAINTAIN 10 FEET FROM CENTER OF STREET TO EDGE
OF ALL UNDERGROUND FACILITIES.
Call Underground Service Alert 5. MAINTAIN 10 FEET FROM ALL STREET LIGHTS, UTILITIES
at least 2 days STRUCTURES AND VALVE BOXES.
before you dig TKA 7�–{� T �/(
Knowwharsbelow. O TREE PLACEMENT
Call before you dig.
2
0
SIDEWALK (WHERE OCCURS)
1 1/2x ROOTBALL SIZE
8"
TREE TRUNK
ROOTBALL
— PIPE CAP
r FIN. GR.
3" DLA. SCH. 80
PVC STAND PIPE
PLANTER BACKFILL MIX
COMPACTED SOIL
BACKFILL
3" DIA. CORRUGATED
A.D.S. PERFORATED
DRAIN PIPE W/ DRAIN
SOCK LAID O BASE
OF ROOTBALL
-HOLD ROOTBALL ABOVE ULTIMATE
FINISHED GRADE:
PLANTING NOTES
WEED CONTROL
WHERE PERENNIAL WEEDS EXIST ON SITE AT THE BEGINNING OF WORK, CLEAN AND REMOVE
THESE EXISTING WEEDS BY MOWING OR GRUBBING OFF ALL PLANT MATERIAL. UPON
COMPLETION OF SOIL PREPARATION AND PLANTING OF ALL SPECIMEN TREES, BEGIN WEED
ABATEMENT PROGRAM BY APPLYING: 100 POUNDS OF A COMMERCIAL FERTILIZER, 46-0-0, PER
ACRE AND PER MANUFACTURER'S SPECIFICATIONS. WATER ALL AREAS FOUR (4) TIMES DAILY
FOR FOURTEEN (14) CONSECUTIVE DAYS UNTIL WEED SEEDS HAVE GERMINATED. CEASE
WATERING FOR THREE (3) DAYS. SPRAY A NON-SELECTIVE, NON -RESIDUAL, SYSTEMIC
HERBICIDE TO ERADICATE GERMINATED WEEDS. LET THE WEEDS DIE WITHOUT IRRIGATION
FOR A MINIMUM DEPTH OF 1/4"INCH BELOW THE SURFACE OF THE SOIL. IF STUBBORN AND
RESIDUAL WEEDS (LE. BERMUDA) SHOULD PERSIST ERADICATION PROCEDURE SHOULD BE
REPEATED. THE TYPE OF WEEDS THAT EXIST SHOULD BE IDENTIFIED AND COORDINATED WITH
AN APPROVED LICENSED PEST CONTROL ADVISOR TO ENSURE COMPATIBILITY WITH CHEMICAL
AND SEASON OF APPLICATION. DO NOT USE MATERIAL OR METHOD THAT WOULD ADVERSELY
EFFECT NEW PLANTINGS, SLOPE STABILIZATION OR HYDROSEEDING.
SOIL TEST
AFTER ALL SOIL HAS BEEN IMPORTED TO THE SITE AND ROUGH GRADING COMPLETED BUT
PRIOR TO SOIL PREPARATION, SEVERAL SOIL SAMPLES SHALL BE TAKEN BY THE SOILS LABORATORY
OR BY THE CONTRACTOR AT THEIR INSTRUCTION AND A REPORT/RECOMENDATION
PRODUCED. THE CONTRACTOR SHALL FURNISH A COPY OF THE SOIL TEST FOR
AGRICULTURAL SUITABILITY AND FERTILITY (PREPARED BY A CALIFORNIA ASSOCIATION OF
AGRICULTURAL LABORATORIES MEMBER) TO THE CONTRACTING OFFICER AND THE CITIES INSPECTOR,
UPON REVIEWING THE SOILS REPORT THE ARCHITECT MAY MAKE SPECIES
SUBSTITUTIONS TO THE PLANT LIST.
SOIL PREPARATION
MACHINE ROTOTILL THE FOLLOWING AMENDMENTS INTO THE SOIL AT RATES INDICATED PER
1000 SF: (THESE RATES ARE FOR BID PURPOSES ONLY, ACTUAL RATES TO CORRESPOND TO
CONTRACTOR'S SOILS REPORT).
4 CU. YDS NITROGEN STABILIZED SAWDUST
150 LBS. GYPSUM
125 LBS STANDARD FERTILIZER
DEEP ROOT BARRIERS
ALL TREES WITHIN 7 FEET OF ANY PERMANENT HARDSCAPE ELEMENT SUCH AS CONCRETE
WALKS, WALLS OR BUILDINGS SHALL BE PLANTED WITH AN APPROPRIATE SIZED ROOT
BARRIER (UNLESS OTHERWISE NOTED ON PLANS). ROOT BARRIER TO BE LINEAR PANEL (TYP.)
SEE DETAIL.
WALK-ON BARK
ALL SHRUB AND GROUNDCOVER AREAS EXCEPT FOR AREA DESIGNATED FOR g" FRACTURED
ROCK SHALL BE TOP DRESSED WITH A 3" LAYER OF 2"-4" FOREST FLOOR OR EQUAL. (SUBMIT
SAMPLE FOR APPROVAL).
NO BARK SHALL BE APPLIED ON TOP OF ROOTBALL OR NEXT TO TRUNK FOR ANY SHRUBS OR
TREES TO HELP PREVENT CROWN ROT.
SPECIAL NOTE
CONTRACTOR SHALL SUPPLY A TOP LAYER OF 3" CLEAN "3/4" -MINUS" TOPSOIL TO
ACHIEVE FINAL FINISH GRADE PRIOR TO "TOP DRESSING" D.G.. ANY ROCK OR
BOULDERS OVER 6" DIA. SHALL BE BURIED A MINIMUM OF 12" DEEP OR REMOVED
FROM THE SITE.
THE CLEAN TOPSOIL CAN EITHER BE GENERATED "ON-SITE" OR IMPORTED. THIS
TOPSOIL, SHOULD BE APPLIED AFTER IRRIGATION AND DRAINAGE WORK HAS
BEEN COMPLETED. QUALITY OF TOPSOIL SHALL BE APPROVED BY THE CITY
PRIOR TO INSTALLATION AND SHALL MEET ALL CITY STANDARDS.
TREE & PLANTING NOTES.
1 FOR 1 GAL
2" FOR 5 & 15 GAL All trees shall be located as follows:
MULCH LAYER PER SPECIFICATIONS
-Amin. of 25 from beginning of curb returns at any
street intersection.
- 10' from light standard or utility enclosures.
GRO POWER FERTILIZER TABLETS. - 5° from fire hydrants.
APPLICATION RATES PER TABLE.
REFER TO SPECS. - A min, of 3' from sidewalk edge, face of wall or back of curb.
BACKFILL MIX PER NOTES.
- For trees shown to be planted within parkway
less than 6' wide, center tree accordingly.
- No tree shall be planted in parkway less than 4' wide.
- Provide appropriate size linear "Century" root barrier
for any tree planted with in 7' of hardscape element,
such as curbs, sidewalks or walls.
HOLD ROOTBALL ABOVE ULTIMATE - Hold center of all shrubs or groundcover a min. of 24"
1
FINISHEDOR D1 GRADE:
away from edge of paving (typ.)
2" FOR 5 & 15 GAL
MULCH LAYER PER SPECIFICATIONS SIZING LEGEND
TEMPORARY 2" HIGH WATER
6"
TREE OR PALM TRUNK
—
— —
ROOTBALL
►0i�i�i0iSo
9ZBOX
3" DIA SCH. 80
BOX
L
PVC STAND PIPE W/
GRO POWER FERTILIZER TABLETS.
APPLICATION RATES PER TABLE.
I-
PIPE CAP
x 54'° BOX
REFER TO SPECS.
LIMITS OF PLANT PIT
Silk Oak
RAISED ROOT PROTECTORS
3" DIA. CORRUGATED A.D.S. PERFORATED
o
o „
RAIN PIPE W/ DRAIN SOCK LAID O
:. z
BASE OF ROOTBALL
PLAN
VIEW
3 '..,%
8"
TREE TRUNK
ROOTBALL
— PIPE CAP
r FIN. GR.
3" DLA. SCH. 80
PVC STAND PIPE
PLANTER BACKFILL MIX
COMPACTED SOIL
BACKFILL
3" DIA. CORRUGATED
A.D.S. PERFORATED
DRAIN PIPE W/ DRAIN
SOCK LAID O BASE
OF ROOTBALL
-HOLD ROOTBALL ABOVE ULTIMATE
FINISHED GRADE:
PLANTING NOTES
WEED CONTROL
WHERE PERENNIAL WEEDS EXIST ON SITE AT THE BEGINNING OF WORK, CLEAN AND REMOVE
THESE EXISTING WEEDS BY MOWING OR GRUBBING OFF ALL PLANT MATERIAL. UPON
COMPLETION OF SOIL PREPARATION AND PLANTING OF ALL SPECIMEN TREES, BEGIN WEED
ABATEMENT PROGRAM BY APPLYING: 100 POUNDS OF A COMMERCIAL FERTILIZER, 46-0-0, PER
ACRE AND PER MANUFACTURER'S SPECIFICATIONS. WATER ALL AREAS FOUR (4) TIMES DAILY
FOR FOURTEEN (14) CONSECUTIVE DAYS UNTIL WEED SEEDS HAVE GERMINATED. CEASE
WATERING FOR THREE (3) DAYS. SPRAY A NON-SELECTIVE, NON -RESIDUAL, SYSTEMIC
HERBICIDE TO ERADICATE GERMINATED WEEDS. LET THE WEEDS DIE WITHOUT IRRIGATION
FOR A MINIMUM DEPTH OF 1/4"INCH BELOW THE SURFACE OF THE SOIL. IF STUBBORN AND
RESIDUAL WEEDS (LE. BERMUDA) SHOULD PERSIST ERADICATION PROCEDURE SHOULD BE
REPEATED. THE TYPE OF WEEDS THAT EXIST SHOULD BE IDENTIFIED AND COORDINATED WITH
AN APPROVED LICENSED PEST CONTROL ADVISOR TO ENSURE COMPATIBILITY WITH CHEMICAL
AND SEASON OF APPLICATION. DO NOT USE MATERIAL OR METHOD THAT WOULD ADVERSELY
EFFECT NEW PLANTINGS, SLOPE STABILIZATION OR HYDROSEEDING.
SOIL TEST
AFTER ALL SOIL HAS BEEN IMPORTED TO THE SITE AND ROUGH GRADING COMPLETED BUT
PRIOR TO SOIL PREPARATION, SEVERAL SOIL SAMPLES SHALL BE TAKEN BY THE SOILS LABORATORY
OR BY THE CONTRACTOR AT THEIR INSTRUCTION AND A REPORT/RECOMENDATION
PRODUCED. THE CONTRACTOR SHALL FURNISH A COPY OF THE SOIL TEST FOR
AGRICULTURAL SUITABILITY AND FERTILITY (PREPARED BY A CALIFORNIA ASSOCIATION OF
AGRICULTURAL LABORATORIES MEMBER) TO THE CONTRACTING OFFICER AND THE CITIES INSPECTOR,
UPON REVIEWING THE SOILS REPORT THE ARCHITECT MAY MAKE SPECIES
SUBSTITUTIONS TO THE PLANT LIST.
SOIL PREPARATION
MACHINE ROTOTILL THE FOLLOWING AMENDMENTS INTO THE SOIL AT RATES INDICATED PER
1000 SF: (THESE RATES ARE FOR BID PURPOSES ONLY, ACTUAL RATES TO CORRESPOND TO
CONTRACTOR'S SOILS REPORT).
4 CU. YDS NITROGEN STABILIZED SAWDUST
150 LBS. GYPSUM
125 LBS STANDARD FERTILIZER
DEEP ROOT BARRIERS
ALL TREES WITHIN 7 FEET OF ANY PERMANENT HARDSCAPE ELEMENT SUCH AS CONCRETE
WALKS, WALLS OR BUILDINGS SHALL BE PLANTED WITH AN APPROPRIATE SIZED ROOT
BARRIER (UNLESS OTHERWISE NOTED ON PLANS). ROOT BARRIER TO BE LINEAR PANEL (TYP.)
SEE DETAIL.
WALK-ON BARK
ALL SHRUB AND GROUNDCOVER AREAS EXCEPT FOR AREA DESIGNATED FOR g" FRACTURED
ROCK SHALL BE TOP DRESSED WITH A 3" LAYER OF 2"-4" FOREST FLOOR OR EQUAL. (SUBMIT
SAMPLE FOR APPROVAL).
NO BARK SHALL BE APPLIED ON TOP OF ROOTBALL OR NEXT TO TRUNK FOR ANY SHRUBS OR
TREES TO HELP PREVENT CROWN ROT.
SPECIAL NOTE
CONTRACTOR SHALL SUPPLY A TOP LAYER OF 3" CLEAN "3/4" -MINUS" TOPSOIL TO
ACHIEVE FINAL FINISH GRADE PRIOR TO "TOP DRESSING" D.G.. ANY ROCK OR
BOULDERS OVER 6" DIA. SHALL BE BURIED A MINIMUM OF 12" DEEP OR REMOVED
FROM THE SITE.
THE CLEAN TOPSOIL CAN EITHER BE GENERATED "ON-SITE" OR IMPORTED. THIS
TOPSOIL, SHOULD BE APPLIED AFTER IRRIGATION AND DRAINAGE WORK HAS
BEEN COMPLETED. QUALITY OF TOPSOIL SHALL BE APPROVED BY THE CITY
PRIOR TO INSTALLATION AND SHALL MEET ALL CITY STANDARDS.
TREE & PLANTING NOTES.
1 FOR 1 GAL
2" FOR 5 & 15 GAL All trees shall be located as follows:
MULCH LAYER PER SPECIFICATIONS
-Amin. of 25 from beginning of curb returns at any
street intersection.
- 10' from light standard or utility enclosures.
GRO POWER FERTILIZER TABLETS. - 5° from fire hydrants.
APPLICATION RATES PER TABLE.
REFER TO SPECS. - A min, of 3' from sidewalk edge, face of wall or back of curb.
BACKFILL MIX PER NOTES.
- For trees shown to be planted within parkway
less than 6' wide, center tree accordingly.
- No tree shall be planted in parkway less than 4' wide.
- Provide appropriate size linear "Century" root barrier
for any tree planted with in 7' of hardscape element,
such as curbs, sidewalks or walls.
HOLD ROOTBALL ABOVE ULTIMATE - Hold center of all shrubs or groundcover a min. of 24"
1
FINISHEDOR D1 GRADE:
away from edge of paving (typ.)
2" FOR 5 & 15 GAL
MULCH LAYER PER SPECIFICATIONS SIZING LEGEND
TEMPORARY 2" HIGH WATER
6"
.WWWE
NOTES:
BASIN. REMOVE ONCE PLANT IS
o
►0i�i�i0iSo
9ZBOX
ESTABLISHEDX2LY
BOX
14
\L2LY48"
GRO POWER FERTILIZER TABLETS.
APPLICATION RATES PER TABLE.
X
5 GALLON ,°L 36" BOX
x 54'° BOX
REFER TO SPECS.
- '•
Silk Oak
RAISED ROOT PROTECTORS
BACKFILL MIX PER NOTES.
o
o „
o „
:. z
TOWARDS THE TREE.
8"
TREE TRUNK
ROOTBALL
— PIPE CAP
r FIN. GR.
3" DLA. SCH. 80
PVC STAND PIPE
PLANTER BACKFILL MIX
COMPACTED SOIL
BACKFILL
3" DIA. CORRUGATED
A.D.S. PERFORATED
DRAIN PIPE W/ DRAIN
SOCK LAID O BASE
OF ROOTBALL
-HOLD ROOTBALL ABOVE ULTIMATE
FINISHED GRADE:
PLANTING NOTES
WEED CONTROL
WHERE PERENNIAL WEEDS EXIST ON SITE AT THE BEGINNING OF WORK, CLEAN AND REMOVE
THESE EXISTING WEEDS BY MOWING OR GRUBBING OFF ALL PLANT MATERIAL. UPON
COMPLETION OF SOIL PREPARATION AND PLANTING OF ALL SPECIMEN TREES, BEGIN WEED
ABATEMENT PROGRAM BY APPLYING: 100 POUNDS OF A COMMERCIAL FERTILIZER, 46-0-0, PER
ACRE AND PER MANUFACTURER'S SPECIFICATIONS. WATER ALL AREAS FOUR (4) TIMES DAILY
FOR FOURTEEN (14) CONSECUTIVE DAYS UNTIL WEED SEEDS HAVE GERMINATED. CEASE
WATERING FOR THREE (3) DAYS. SPRAY A NON-SELECTIVE, NON -RESIDUAL, SYSTEMIC
HERBICIDE TO ERADICATE GERMINATED WEEDS. LET THE WEEDS DIE WITHOUT IRRIGATION
FOR A MINIMUM DEPTH OF 1/4"INCH BELOW THE SURFACE OF THE SOIL. IF STUBBORN AND
RESIDUAL WEEDS (LE. BERMUDA) SHOULD PERSIST ERADICATION PROCEDURE SHOULD BE
REPEATED. THE TYPE OF WEEDS THAT EXIST SHOULD BE IDENTIFIED AND COORDINATED WITH
AN APPROVED LICENSED PEST CONTROL ADVISOR TO ENSURE COMPATIBILITY WITH CHEMICAL
AND SEASON OF APPLICATION. DO NOT USE MATERIAL OR METHOD THAT WOULD ADVERSELY
EFFECT NEW PLANTINGS, SLOPE STABILIZATION OR HYDROSEEDING.
SOIL TEST
AFTER ALL SOIL HAS BEEN IMPORTED TO THE SITE AND ROUGH GRADING COMPLETED BUT
PRIOR TO SOIL PREPARATION, SEVERAL SOIL SAMPLES SHALL BE TAKEN BY THE SOILS LABORATORY
OR BY THE CONTRACTOR AT THEIR INSTRUCTION AND A REPORT/RECOMENDATION
PRODUCED. THE CONTRACTOR SHALL FURNISH A COPY OF THE SOIL TEST FOR
AGRICULTURAL SUITABILITY AND FERTILITY (PREPARED BY A CALIFORNIA ASSOCIATION OF
AGRICULTURAL LABORATORIES MEMBER) TO THE CONTRACTING OFFICER AND THE CITIES INSPECTOR,
UPON REVIEWING THE SOILS REPORT THE ARCHITECT MAY MAKE SPECIES
SUBSTITUTIONS TO THE PLANT LIST.
SOIL PREPARATION
MACHINE ROTOTILL THE FOLLOWING AMENDMENTS INTO THE SOIL AT RATES INDICATED PER
1000 SF: (THESE RATES ARE FOR BID PURPOSES ONLY, ACTUAL RATES TO CORRESPOND TO
CONTRACTOR'S SOILS REPORT).
4 CU. YDS NITROGEN STABILIZED SAWDUST
150 LBS. GYPSUM
125 LBS STANDARD FERTILIZER
DEEP ROOT BARRIERS
ALL TREES WITHIN 7 FEET OF ANY PERMANENT HARDSCAPE ELEMENT SUCH AS CONCRETE
WALKS, WALLS OR BUILDINGS SHALL BE PLANTED WITH AN APPROPRIATE SIZED ROOT
BARRIER (UNLESS OTHERWISE NOTED ON PLANS). ROOT BARRIER TO BE LINEAR PANEL (TYP.)
SEE DETAIL.
WALK-ON BARK
ALL SHRUB AND GROUNDCOVER AREAS EXCEPT FOR AREA DESIGNATED FOR g" FRACTURED
ROCK SHALL BE TOP DRESSED WITH A 3" LAYER OF 2"-4" FOREST FLOOR OR EQUAL. (SUBMIT
SAMPLE FOR APPROVAL).
NO BARK SHALL BE APPLIED ON TOP OF ROOTBALL OR NEXT TO TRUNK FOR ANY SHRUBS OR
TREES TO HELP PREVENT CROWN ROT.
SPECIAL NOTE
CONTRACTOR SHALL SUPPLY A TOP LAYER OF 3" CLEAN "3/4" -MINUS" TOPSOIL TO
ACHIEVE FINAL FINISH GRADE PRIOR TO "TOP DRESSING" D.G.. ANY ROCK OR
BOULDERS OVER 6" DIA. SHALL BE BURIED A MINIMUM OF 12" DEEP OR REMOVED
FROM THE SITE.
THE CLEAN TOPSOIL CAN EITHER BE GENERATED "ON-SITE" OR IMPORTED. THIS
TOPSOIL, SHOULD BE APPLIED AFTER IRRIGATION AND DRAINAGE WORK HAS
BEEN COMPLETED. QUALITY OF TOPSOIL SHALL BE APPROVED BY THE CITY
PRIOR TO INSTALLATION AND SHALL MEET ALL CITY STANDARDS.
TREE & PLANTING NOTES.
1 FOR 1 GAL
2" FOR 5 & 15 GAL All trees shall be located as follows:
MULCH LAYER PER SPECIFICATIONS
-Amin. of 25 from beginning of curb returns at any
street intersection.
- 10' from light standard or utility enclosures.
GRO POWER FERTILIZER TABLETS. - 5° from fire hydrants.
APPLICATION RATES PER TABLE.
REFER TO SPECS. - A min, of 3' from sidewalk edge, face of wall or back of curb.
BACKFILL MIX PER NOTES.
- For trees shown to be planted within parkway
less than 6' wide, center tree accordingly.
- No tree shall be planted in parkway less than 4' wide.
- Provide appropriate size linear "Century" root barrier
for any tree planted with in 7' of hardscape element,
such as curbs, sidewalks or walls.
HOLD ROOTBALL ABOVE ULTIMATE - Hold center of all shrubs or groundcover a min. of 24"
1
FINISHEDOR D1 GRADE:
away from edge of paving (typ.)
2" FOR 5 & 15 GAL
MULCH LAYER PER SPECIFICATIONS SIZING LEGEND
TEMPORARY 2" HIGH WATER
6"
2 6" 1
NOTES:
BASIN. REMOVE ONCE PLANT IS
o
1 GALLON ACELX30" BOX
9ZBOX
ESTABLISHEDX2LY
BOX
14
\L2LY48"
GRO POWER FERTILIZER TABLETS.
APPLICATION RATES PER TABLE.
X
5 GALLON ,°L 36" BOX
x 54'° BOX
REFER TO SPECS.
- '•
Silk Oak
RAISED ROOT PROTECTORS
BACKFILL MIX PER NOTES.
o
o „
o „
B 15 GALLON 42 BOX 60 BOX
4° - 24" BOX ga�cates quantity Indicates palm
x Indicates species x B.T.H. as noted.
* Denotes trees that are to be tagged by the Landscape Architect.
F=
PLANTING LEGEND
TREES
SYMBOL KEY BOTANICAL NAME COMMON NAME COMMENTS SIZE (QTY WUCOLS
LODGE POLE
TREE TRUNK
e---- WONDER TIE
(DO NOT 'TWIST)
PREVAILING WIND
DIRECTION
NONDER TREE TIE" – WRAP WIRE AROUND
iUTSIDE OF STAKE. SECURE TO STAKE
'ER MANUFACTURVS RECOMMENDATION
'LACE BELOW BRANCHING YOKE OF TREE
(2) 3" DIA x 10' LONG LODGEPOLE PINE STAKES:
LOCATE OUTSIDE OF ROOTBALL
ARBOR GUARD IN TURF AREAS
SET TOP OF ROOTBALL 3' ABOVE FINISH
GRADE INSTALL 4" LAYER OF NITROLIZED
WOOD CHIP MULCH.
WATER BASIN , REMOVE ONCE PLANT IS
ESTABLISHED PER LANDSCAPE ARCH DIRECTION
PLANT PR ORAIN WHEN REQUIRED
PER SEPARATE DETAIL
GRD POWER FERTILIZER TABLETS.
APPLICATION RATES PER TABLE. REFER
TO PLANTING NOTES.
BACKFILL MIX PER SPECS.
NATIVE SOIL SUBGRADE
EXCAVATE TO CORRECT HEIGHT
FOR PLANnNG. SCARIFY BOTTOM
TO ENSURE ADEQUATE DRAINAGE
FOR HEALTHY GROWTH OF PIAT.
SCHEDULE OF PIT EXCAVATION
5GAL –X-6"
15 GAL – X - go
24" LOX – –X ® 12' MAX.
le i" r lo r O r 9 l]
A Arbutus marina
B1 Citrus x sinensis 'dwarf
B2 Citrus x limon
C Grevillea robusta
Strawberry Tree
6"
2 6" 1
NOTES:
1
MIN,
MIN.
A. POSITION BARRIER AS
24"
BOX
14
CLOSE TO CURB OR
Lemon
Std.
24"
SIDEWALK AS POSSIBLE.
6
- '•
Silk Oak
RAISED ROOT PROTECTORS
24"
®•
'+
SHALL BE FACING
:. z
TOWARDS THE TREE.
3 '..,%
N
B. TOP OF BARRIER SHALL
too
3
BE 1" ABOVE FINISHED
4 .. '
GRADE.
•
4
C. LENGTH OF ROOT BARRIER
SHALL BE EQUAL TO
THE ULTIMATE DRIPLINE OF
THE PARTICULAR TREE, OR
10' MAX.
\
LEGEND:
1D CONCRETE CURB OR
A— ®�'
•+._ "
®'
HARDSCAPE
L_—/�— �-- _ ..;—°:.•_,_
j
FINISHED GRADE
I
I
APPROVED ROOT CONTROL
I
I
BARRIER
® 3/4" TO 1 1/2" GRAVEL
OR CRUSHED ROCK
I
Q DRIP E OF EE
NOF
I
I
CENTER TREE
4
6 f 7
Q PARKWAY WIDTH
I
I
ROOT BARRIER IS TO BE 18"
LINEAR BARRIER UB 18-2
I
I
WHEN ADJACENT TO WALK
T —•
OR HARDSCAPE OR 24"
F'-----� a : s—=;
LINEAR BARRIER
ia' • ' ' •
I
UB 24-2 WHEN ADJACENT
TO CURB
/
\
AVAILABLE FROM:
i 1
CENTURY PRODUCTS
1144 N. GROVE ST.
ANAHEIM, 92806
ALIGN W/
ALIGN W/
—
(714) 632-7083
DRIPLINE
DRIPLINE
OR 'i
OR
PER MFR. OF TREE
PER MFR.
SPEC.
SPEC.
B 15 GALLON 42 BOX 60 BOX
4° - 24" BOX ga�cates quantity Indicates palm
x Indicates species x B.T.H. as noted.
* Denotes trees that are to be tagged by the Landscape Architect.
F=
PLANTING LEGEND
TREES
SYMBOL KEY BOTANICAL NAME COMMON NAME COMMENTS SIZE (QTY WUCOLS
LODGE POLE
TREE TRUNK
e---- WONDER TIE
(DO NOT 'TWIST)
PREVAILING WIND
DIRECTION
NONDER TREE TIE" – WRAP WIRE AROUND
iUTSIDE OF STAKE. SECURE TO STAKE
'ER MANUFACTURVS RECOMMENDATION
'LACE BELOW BRANCHING YOKE OF TREE
(2) 3" DIA x 10' LONG LODGEPOLE PINE STAKES:
LOCATE OUTSIDE OF ROOTBALL
ARBOR GUARD IN TURF AREAS
SET TOP OF ROOTBALL 3' ABOVE FINISH
GRADE INSTALL 4" LAYER OF NITROLIZED
WOOD CHIP MULCH.
WATER BASIN , REMOVE ONCE PLANT IS
ESTABLISHED PER LANDSCAPE ARCH DIRECTION
PLANT PR ORAIN WHEN REQUIRED
PER SEPARATE DETAIL
GRD POWER FERTILIZER TABLETS.
APPLICATION RATES PER TABLE. REFER
TO PLANTING NOTES.
BACKFILL MIX PER SPECS.
NATIVE SOIL SUBGRADE
EXCAVATE TO CORRECT HEIGHT
FOR PLANnNG. SCARIFY BOTTOM
TO ENSURE ADEQUATE DRAINAGE
FOR HEALTHY GROWTH OF PIAT.
SCHEDULE OF PIT EXCAVATION
5GAL –X-6"
15 GAL – X - go
24" LOX – –X ® 12' MAX.
le i" r lo r O r 9 l]
A Arbutus marina
B1 Citrus x sinensis 'dwarf
B2 Citrus x limon
C Grevillea robusta
Strawberry Tree
Std.
24"
Box
8
M
Orange Dwarf
Std.
24"
BOX
14
M
Lemon
Std.
24"
BOX
6
M
Silk Oak
Std.
24"
BOX
5
M
D Lagerstroemia indica'Muskogee' Crape Myrtle
E Pyrus calleryana `Aristrocrat' Aristrocrat Pear
F Quercus agrifolia
G Specimen Tree
H Platanus acerifolia
Coast Live Oak
To be selected
Std. 24" BOX 3 M
Std, 24" BOX 13 M
Accent 60" BOX 2 L
Std.
Hertiage 84" Box 1 M
Std.
London Plane Tree Std. 24" Box 13 M
GROUNDCOVER
I Turf Grass Marathon II Sodded 10,899 S.F. H
rrj/irr�rrrii-
jj/rijiri jirjrr
J 2" layer of 3/8" crushed decorative rock over native. 2,970 S.F.
rr r%ii%%irirr Color to be "Sandalwood" by Southwest Boulder &
Stone.
SHRUBS
SYMBOL KEY BOTANICAL NAME COMMON NAME SIZE QTY, WUCOLS
1 Carissa grandiflora'Green Carpet' Natal Plum 1G @ 30" o.c. 377 L
2 Dianella tasmanica'Silver Streak' Silver Streak Flax Lily 5G 562 M
® 3 Hemerocallis 'Dwarf Yellow' Day Lily 5G 177 M
O4 Leymus condensatus 'Canyon Prince' Canyon Prince Wild Rye 5G 176 L
O5 Ligustrum japonicum'Texanum' Wax Leaf Privet 5G 31 M
6 Pittosporum tobira Tobira 5G 220 M
® 7 Rhaphiolepis indica 'Clara' Dwarf Indian Hawthorne 5G 311 M
CITY OF FONTANA
LANDSCAPE PLANS
°""' W.
VALLEY OAK PARK
PLANTING DETAILS, NOTES & LEGEND
SHOWN
DENO= en
& M I
CHMM W.
Ar PWM snt _
DAIM
OW NO-
5685
14
18
'AIRY-W.C.E."J1164 f78P. W1E
T IE C A P It
Landscape Architecture
and Planning
3190 B2 Airport Loop Drive
Costa Mesa, CA 92626
Richard Polhamus, License CA—#2782
(949) 614-9370 (714) 210-3140 FAX
NO. REVISION
A
V
rl �
Z "--
IE—I
C)
�I
O U 0
V. -I 6
�WPool rl� ,
C:�
®U
�
�PODSCA pE,
��& SRO b 90I yq
PC*
LSPC 17-0016
DATE 02/27/17
J®a 16-033
L13
14 OF 18
•
�PODSCA pE,
��& SRO b 90I yq
PC*
LSPC 17-0016
DATE 02/27/17
J®a 16-033
L13
14 OF 18