Loading...
HomeMy WebLinkAbout5684-2I I T E S C A P E S Landscape Architecture and Planning 3190 B2 Airport Loop Drive Costa Mesa, CA 92626 Richard Polhomus, License CA—//2782 (949) 844-0370 (714) 210-3140 FAX 1 ev ZZ>00 kA O F—I ;z s U P4Z® ® H r l C) V �� �ANDSC4 F w PC* LSPC 17-0020 DATE 03/13/17 JOB # 16-026 L 1 OF 11 TREE OR PALM TRUNK PLANTING NOTES cB SIDEWALK (WHERE OCCURS) ROOTBALL 3 rd LODGE POLE a PIPE CAP WEED CONTROL W Wn WWHERE FIN. OR. PERENNIAL WEEDS EXIST ON SITE AT THE BEGINNING OF WORK, CLEAN AND REMOVE F THESE EXISTING WEEDS BY MOWING OR GRUBBING OFF ALL PLANT MATERIAL. UPON TREE TRUNK j• '? COMPLETION OF SOIL PREPARATION AND PLANTING OF ALL SPECIMEN TREES, BEGIN WEED ABATEMENT PROGRAM BY APPLYING: 100 POUNDS OF A COMMERCIAL FERTILIZER, 46-0-0, PER WONDER TIE 7 (DO NOT TWIST) O "DIA SCH. 80 PVC STAND PIPE ACRE AND PER MANUFACTURER'S SPECIFICATIONS. WATER ALL AREAS FOUR (4) TIMES DAILY ,�0�•7J° °nn Jj PREVAILING WIND PLANTER BACKFILL MIX FOR FOURTEEN (14) CONSECUTIVE DAYS UNTIL WEED SEEDS HAVE GERMINATED. CEASE WATERING FOR THREE DAYS. SPRAY A NON-SELECTIVE, NON SYSTEMIC D DIRECTIONM O IL (3) -RESIDUAL, HERBICIDE ERADICATE GERMINATED WEEDS. LET THE DIE WITHOUT IRRIGATION TO WEEDS FOR A MINIMUM DEPTH OF 1/4"INCH BELOW THE SURFACE OF THE SOIL. IF STUBBORN AND 7 COMPACTED SOIL BACKFILL RESIDUAL WEEDS (I.E. BERMUDA) SHOULD PERSIST ERADICATION PROCEDURE SHOULD BE avvov.........00 vovov voavo aovoo REPEATED. THE TYPE OF WEEDS THAT EXIST SHOULD BE IDENTIFIED AND COORDINATED WITH 2 SETS OF "WONDER TREE -TIE" - WRAP WIRE AROUND - 3" DIA CORRUGATED A.D.S. PERFORATEDIN AN APPROVED LICENSED PEST CONTROL ADVISOR TO ENSURE COMPATIBILITY WITH CHEMICAL w OUTSIDE OF STAKE. SECURE TO STAKE W/ 1" WOOD SCREWS RAPIPE W/ DRAIN ----- - '- AND SEASON OF APPLICATION. DO NOT USE MATERIAL OR METHOD THAT WOULD ADVERSELY PLACE BELOW BRANCHING YOKE OF TREE 1 1 /2x ROOTBALL SIZE SOCK LAID ® BASE EFFECT NEW PLANTINGS, SLOPE STABILIZATION OR HYDROSEEDING. e OF ROOTBALL (2) 3' DIA. x 10' LONG LODGEPOLE PINE STAKES: , SOIL TEST LOCATE OUTSIDE OF ROOTBALL AFTER ALL SOIL I -LAS BEEN IMPORTED TO THE SITE AND ROUGH GRADING COMPLETED BUT ARBOR GUARD IN TURF AREAS SECTION PRIOR TO SOIL PREPARATION, SEVERAL SOIL SAMPLES SHALL BE TAKEN BY THE SOILS LABORATORY SET TOP OF ROOTBALL 8" ABOVE FINISHOR BY THE CONTRACTOR AT THEIR INSTRUCTION AND A REPORT/RECOMENDATION c GRADE. INSTALL 4" LAYER OF NfTROUZED 90% COMPACTED SOIL PRODUCED. THE CONTRACTOR SHALL FURNISH A COPY OF THE SOIL TEST FOR WOOD CHIP MULCH. AGRICULTURAL SUITABILITY AND FERTILITY (PREPARED BY A CALIFORNIA ASSOCIATION OF TREE OR PALM TRUNK AGRICULTURAL LABORATORIES MEMBER) TO THE CONTRACTING OFFICER AND THE CITIES INSPECTOR, DEEP ROOT BARRIER IF WITHIN 5' OF ANY r UPON REVIEWING THE SOILS REPORT THE ARCHITECT MAY MAKE SPECIES 00 FG HARDSCAPE (SEE DETAIL) I ROOTBALL SUBSTITUTIONS TO THE PLANT LIST. 10 WATER BASIN REMOVE ONCE PLANT IS I I 'SOIL PREPARATION K ESTABLISHED ER LANDSCAPE ARCH DIRECTION 3" DIA. SCH. 80 PVC STAND PIPE W/ NOTES: APPROX. BOULDER FOOTPRINT SIZES MACHINE ROTOTILL THE FOLLOWING AMENDMENTS INTO THE SOIL AT RATES INDICATED PER a '1 PLANT PIT DRAIN WHEN REQUIRED ® I ), (PER SEPARATE DETAIL) r11`, PIPE CAP � � I LIMITS OF PLANT PIT O1 BURY A MINIMUM OF 1/3 DEPTH iF21 2° X 2' X 2°= $ CU/FT OF BOULDER SIZE. 1000 SF: HESE RATES ARE FOR BID PURPOSES ONLY, ACTUAL RATES TO CORRESPOND TO � CONTRACTOR'S SOILS REPORT). I 1 4 CU. YDS NITROGEN STABILIZED SAWDUST o GRO POWER FERTILIZER TABLETS. APPLICATION RATES PER TABLE. REFER — — — \ J `_ _ _ _ 3" DA. CORRUGATED A.D.S. PERFORATED o2 55 l3' 3' X 3° X 3= 27 CU FT BOULDER – SEE ON SHEET / 150 LBS. GYPSUM 125 LBS STANDARD FERTILIZER I NOTES. RAIN PIPE W/ DRAIN SOCK LAID ® L1 FOR SPECIFICA N TO PLANTING BASE OF ROOTBALL O3 SCARRED OR BROKEN BOULDERS 4' X 4' X 4' 64 CU/FT BACKFILL MIX PER SPECS. PLAN VIEW SHALL NOT BE PERMITTED. DEEP ROOT BARRIERS a NATIVE SOIL SUBGRADE ALL TREES WITHIN 7 FEET OF ANY PERMANENT HARDSCAPE ELEMENT SUCH AS CONCRETE a EXCAVATE TO CORRECT HEIGHT FOR PLANTING. SCARIFY BOTTOM ® PLACE PER PLANS AND WALKS, WALLS OR BUILDINGS SHALL BE PLANTED WITH AN APPROPRIATE SIZED ROOT TO ENSURE ADEQUATE DRAINAGE LANDSCAPE ARCHITECT'S DIRECTION BARRIER (UNLESS O'T'HERWISE NOTED ON PLANS). ROOT BARRIER TO BE LINEAR PANEL (TYP.) FOR HEALTHY GROWTH OF PLANT. SEE DETAIL. 21X ROOTBALL SCHEDULE OF PIT EXCAVATION TOP DRESSING (FUEL MODIFICATION AREA) 5 CAL - x - e" 15 GAL - X - 9" ALL SHRUB AND GROUNDCOVER AREAS SHALL BE TOP DRESSED WITH A 1 "-1/2" LAYER OF DECOMPOSED 24" BOX OR LARGER - -X = 12" MAX. GRANITE/FRACTURED ROCK. SEE TOP DRESSING LEGEND FOR SPECIFICATIONS (SUBMIT SAMPLE TO CITY LANDSCAPE ARCHITECT FOR APPROVAL) O O PIT DRAIN DETAIL O BOULDER INSTALLATION DETAIL TREE STAKING SPECIAL NOTE CONTRACTOR SHALL SUPPLY A TOP LAYER OF 3" CLEAN "3/4" -MINUS" TOPSOIL TO ACHIEVE FINAL FINISH GRADE PRIOR TO "TOP DRESSING" D.G.. ANY ROCK OR BOULDERS OVER 6" DIA. SHALL BE BURRIED A MINIMUM OF 12" DEEP OR REMOVED FROM THE SITE. THE CLEAN TOPSOIL CAN EITHER BE GENERATED "ON-SITE" OR IMPORTED. THIS TOPSOIL SHOULD BE APPLIED AFTER IRRIGATION AND DRAINAGE WORK HAS BEEN COMPLETED. QUALITY OF TOPSOIL SHALL BE APPROVED BY THE CITY PRIOR TO INSTALLATION AND SHALL MEET ALL CITY STANDARDS. TREE & PLANTING NOTES. HOLD ROOTBALL ABOVE ULTIMATE 3Ti FINISHED GRADE: 2 U.1All trees shall be located as follows: �1 1 FOR 1 GALUJ J 2" FOR 5 & 15 GAL 1 /2' R• (TYP•) T m - A min. of 25' from beginning of curb returns at any street intersection. — — DG LAYER PER SPECIFICATIONS 1 4 a _ III _ - 10' from light standard or utility enclosures. 0 311IL-IL - - ,.' •: :: r :. r w O -III=1 ; .®' 9. :. '' - 5' from fire hydrants. SECTION c IIS, •'•• ;.•. , • ; VIII GRO POWER FERTILIZER TABLETS. f -ll • -Amin, of 3' from sidewalk edge, face of wall or back of curb. 5 GRAM AGRIFORM .. ,. , • +; .,. ,.• APPLICATION RATES PER TABLE. ,•- .°•• :•'+ TO SPECS. '• TABLETS SEE SPECS. REFER –1 _ 1� –m �i l=1– BACKFILL MIX PER NOTES. LEE Tr -For trees shown to be planted within parkway 1 " DEEP DG MULCH LAYER -� less than 6' wide, center tree accordin 1 . accordingly. ::.......:.::::::::::.......................... ........................... o° 1 TILLED & AMENDED PLANTING MIN. - No tree shall be planted in parkway less than 4' wide. P p Y jO �/ o� % /Y- BED PER SOIL TEST 6" 3 - Provide appropriate size linear "Century" root barrier -NATURAL SUBGRADE for any tree planted with in T of hardscape element, I I O1 FINISH GRADE such as curbs, sidewalks or walls. - Hold center of all shrubs or groundcover a min. of 24" F HOLD ROOTBALL ABOVE ULTIMATE O CONCRETE CURB –NATURAL COLOR CONCRETE away from edge of paving (typ.) GROUNDCOVER PLANTS �%P G9 GROUNDCOVER �� FINISH GRADE FIN GRADE: AL 2" FOR 5 & 15 GAL O (1) #3 REBAR – CONTINUOUS SEE PLANTING PLANS — SIZING LEGEND FOR SPACING.. \ DG LAYER PER SPECIFICATIONS 4 T 6 o D.G. TOP COAT o 1 DEEP DG MULCH LAYER. o III-III=ill=ll •• . I Ali= _� •• :a:' " TEMPORARY 2 HIGH WATER BASIN. REMOVE ONCE PLANT IS o 1 GALLON o n BOX o n BOX x LLX 30 x 48 / ::, •; III i ..: ' ESTABLISHED GRO POWER FERTILIZER TABLETS. x 5 GALLON Ill 36" BOX X 54" BOX PLAN N • III i1-111 :' "' '- "`'. ` .'° , `'° int'':"t:':''+•t.°:; i�•: =1tll APPLICATION RATES PER TABLE. REFER TO SPECS. X 15 GALLON X 42" BOX X 60" BOX III–III-II I" II III–III- -1I�L� ITS I E I I III -1I I I1=1I BACKFILL MIX PER NOTES. �- 24" BOX GIndlcates quantity Indicates paha 8" x Indicates species x B.T.H. as noted. MIN. Denotes trees that are to be tagged by the Landscape Architect. �4 GROUNDCOVER PLANTING O SHRUB PLANTING O CONCRETE HEADER CONSTRUCTION SCHEDULE STORM DRAIN/ UNDERGROUND UTILITIES R I 6" 2 6" 1 NOTES: Concrete sidewalk -Per C.E. Plans SEE NOTE 3 1 MIN. MIN. A. POSITION BARRIER AS 5' J CLOSE TO CURB OR ( �) Sight Line - Per C.E. Plans �J ;. SIDEWALK AS POSSIBLE. • •• 7. RAISED ROOT PROTECTORS & it r e 11 1 Perlmeter wall pilaster per C.E. wall pans e Z : M N `'' SHALL BE FACING TOWARDS THE TREE. 4 1 2 3 4 7 5 (4) Install 2" layer of 3/4" "Apache Sunset" fractured rock. Rock available from Southwest Boulder `�� z SIDEWALK UTILI I 3 B. TOP OF BARRIER SHALL & Stone (760) 342-5522. Provide Permaloc C1eanLine 1/8" x 4" aluminum header with mill 4 N 3 =_ BE 1" ABOVE FINISHED GRADE. C. LENGTH OF ROOT BARRIER SHALL BE EQUAL TO FLUSH finish. Set flush with top of gravel and install per manufacture's specification. See detail 9, sheet L-1 5 'Blasted Granite' landscape boulders from Southwest Boulder & Stone (760) 342-5522 Install per a CURB AND GUTTER--"'w UTTER METER—1 10' 5' \ \ \ \ TYP. TYP. ►{ THE ULTIMATE DRIPLINE OF r o o o p o vo i�l boulder installation detail 3, sheet L-1. Numbers indicate boulder size in total cubic feet (8 total - THE PARTICULAR TREE, OR this plan). STRUCTURE 10° MAX. � UNDERGROUND CATCH BASIN / \ LEGEND: s»w°eoL Fractured Rock Top Dressing: Install a V - 1 1/2" layer of 'Mojave Gold' 3/8" fractured rock over — TRANSFORMER VAULT. 1 .... ', 4• .. ,. L'__�___.' "� _ ' _"®_ •_" •.,=� j / O CONCRETE CURB OR HARDSCAPE Q FINISHED GRADE Smooth finish grade as mulch/bark Substitute after all planting. Submit Sample to Landscape Architect for approval prior to installation. Available from Southwest Boulder &Stone (760) 342-5522. SIDEWALK w DRIVE I S.L. a X10' z APPROACH 19 = I 1 \ f I 1 © APPROVED ROOT CONTROL BARRIER ®3/4'° TO 1 1/2" GRAVEL OR CRUSHED ROCK DRIP LINE OF TREE A�E5 (7 j Street Lighting per C.E. plans (8) Catch basin per C.E. plans CURB AND GUTTER 5' S' 10' 10' -jl MIN MIN MIN MIN I j CENTER OF TREE 6 4 i 17 PARKWAY WIDTH O1 FINISH GRADE/ADJACENT PLANTING 5' MIN 1ROOT I I BARRIER IS TO BE 18" LINEAR BARRIER UB 18-2 2O PERMALOCK SPLICING STAKE LINE STAKE, INSTALL PER / NOTES: \ I I WHEN ADJACENT TO WALK MANUFACTURER'S SPECIFICATIONS. 1. TREE SPACING SHALL CONFORM TO PLANS APPROVED BY\ I a P _ ar. a• , / OR HARDSCAPE OR 24" 3 / PERMALOCK 1 8" x 4" ML. FINISH ALUMINUM EDGING. NATURAL THE CITY ENGINEER AND FUEL MODIFICATION PLAN. ' ' '� '• \ I I �° LINEAR BARRIER UB 24-2 WHEN ADJACENT ALUMINUM COLOR. INSTALL PER MANUFACTURER'S SPECIFICATIONS. (+ IiUIi llrftj] 2. ALL TREES IN THE R.O.W. ARE SUBJECT TO LINE.OF.SIGHT TO CURB4 CRITERIA AS APPROVED BY TRAFFIC ENGINEER. \ / COMPACTED NATIVE SUB–GRADE 0 o 3. AT ALL LOCAL RESIDENTIAL INTERSECTIONS THE FIRST TWO \ � AVAILABLE FROM: ® DECORATIVE ROCK MULCH PER PLAN – DEPTH VARIES PARKWAY TREES AT ALL APPROACHES TO BE PLACED BEHIND SIDEWALK. i — —' 1 CENTURY PRODUCTS CENT N. GROVE ST. 4. MAINTAIN 10 FEET FROM CENTER OF STREET TO EDGE ALIGN W/ ALIGN W/ ANAHEIM, CA 92806 (714) 632-7083 CITY OF FONTANA OF ALL UNDERGROUND FACILITIES. DRIPLINE DRIPLINE 5. MAINTAIN 10 FEET FROM ALL STREET LIGHTS, UTILITIES OR OR CFD LANDSCAPE PLANS (TR:19961-LOT'D') Call Underground Service Alert PER MFR. OF TREE PER MFR. p..,". STRUCTURES AND VALVE BOXES. SPEC. SPEC. , an CYPRESS AVENUE AS SHOWN at least 2 days (WEST SIDE STA. 50+00 TO 2+27 before you dig KnowCall bsore O TREE PLACEMENT DEsioRm PLANTING DETAILS NOTES & LEGEND, AP� O — =� f ===--- � ---- ° ' t 2 Og ROOT BARRIER O PERMALOC ALUMINUM HEADER Cwharsoreyoedlg, you 5684 11 an,me RCE 899m ow. u I I T E S C A P E S Landscape Architecture and Planning 3190 B2 Airport Loop Drive Costa Mesa, CA 92626 Richard Polhomus, License CA—//2782 (949) 844-0370 (714) 210-3140 FAX 1 ev ZZ>00 kA O F—I ;z s U P4Z® ® H r l C) V �� �ANDSC4 F w PC* LSPC 17-0020 DATE 03/13/17 JOB # 16-026 L 1 OF 11