Loading...
HomeMy WebLinkAbout5680-6,l3 110NOWA 11 MATCHLINE "B" - THIS SHEET !��f.., �l�'s��',✓..�7 ,,,��£'6��//D/%l%: I ..,.fk{i&� ?Yld�i��\� N:"gni I I� I� CO L_: J LARKSTONE STREET (11F) F.. d„4-._,.A_WA':, -_.-_-' ,,,X7 MATCHLINE 11A11- THIS SHEET IRRIGATION NOTES 1 IF ANY OF THE POC INFORMATION SHOWN ON THESE DRAWING IS FOUND TO BE DIFFERENT THAN THE ACTUAL POC INFORMATION IN THE FIELD CONTACT THE LANDSCAPE ARCHITECT PRIOR TO COMMENCING WORK. 2 ALL LOCAL MUNICIPAL AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK. ARE HEREBY INCORPORATED INTO AND MADE A PART OFTHESE SPECIFICATIONS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR. 3 THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES, STRUCTURES AND SERVICES BEFORE COMMENCING WORK. THE LOCATIONS OF UTILITIES, STRUCTURES AND SERVICES SHOWN IN THESE PLANS ARE APPROXIMATE ONLY. ANY DISCREPANCIES BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE. 4 THE CONTRACTOR SHALL OBTAIN THE PERTINENT ENGINEERING OR ARCHITECTURAL PLANS BEFORE BEGINNING WORK. 5 THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED TO PERFORM THE WORK INDICATED HEREIN BEFORE BEGINNING WORK. 6 THIS DESIGN IS DIAGRAMMATIC. ALL EQUIPMENT SHOWN IN PAVED AREAS IS FOR DESIGN CLARITY ONLY AND IS TO BE INSTALLED WITHIN PLANTING AREAS. MAINLINE SHALL BE LOCATED 18" OFF OF ADJACENT HARDSCAPE OR OTHER OBSTACLES TYP. THE CONTRACTOR SHALL NOT WILLFULLY INSTALL ANY EQUIPMENT AS SHOWN ON THE PLANS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN CONDITIONS EXISTTHAT WERE NOT EVIDENT AT THE TIME THESE PLANS WERE PREPARED. ANY SUCH CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE PRIOR TO ANY WORK OR. THE IRRIGATION CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR ANY FIELD CHANGES DEEMED NECESSARY BY THE OWNER. 8 INSTALL ALL EQUIPMENT AS SHOWN IN THE DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH LOCAL CITY, COUNTY AND STATE REQUIREMENTS FOR BOTH EQUIPMENT AND INSTALLATION. 9 ALL PIPE UNDER PAVED AREAS TO BE INSTALLED IN SLEEVING TWICE THE DIAMETER OF THE PIPE CARRIED. SEE LEGEND FOR TYPE. ALL WIRE UNDER PAVED AREAS TO BE INSTALLED IN A SCH. 40 SLEEVE THE SIZE REQUIRED TO EASILY PULL WIRE THROUGH. ALL SLEEVES TO BE INSTALLED WITH A MINIMUM DEPTH AS SHOWN ON THE SLEEVING DETAILS. SLEEVES TO EXTEND AT LEAST 12" PAST THE EDGE OF THE PAVING. 10 ALL REMOTE CONTROL VALVES TO BE INSTALLED IN SHRUB OR GROUND COVER AREAS WHERE POSSIBLE. ALL QUICK COUPLER AND REMOTE CONTROL VALVES TO BE INSTALLED AS SHOWN ON THE INSTALLATION DETAILS. INSTALL ALL QUICK COUPLER AND REMOTE CONTROL VALVES WITHIN 18" OF HARDSCAPE. I 1 NO LOW HEAD DRAINAGE ALLOWED 12 THE CONTRACTOR SHALL USE PROPER GROUNDING TECHNIQUES FOR GROUNDING THE CONTROLLER AND RELATED EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. 13 PRESSURE REGULATING DEVICES ARE REQUIRED IF WATER PRESSURE IS BELOW OR EXCEEDS THE RECOMMENDED PRESSURE OF THE SPECIFIED IRRIGATION DEVICES. 14 CHECK VALVES OR ANTI -DRAIN VALVES ARE REQUIRED ON ALL SPRINKLER HEADS WHERE LOW POINT DRAINAGE COULD OCCUR. 15 A DIAGRAM OF THE IRRIGATION PLAN SHOWING HYDROZONES SHALL BE KEPT WITH THE IRRIGATION CONTROLLER FOR SUBSEQUENT MANAGEMENT PURPOSES. A-13 _ _ - 14 y — �� _ — •\T " p I i ' - O C "/V TO BE A 1 2" METER WITH 2" SERVICE LINE _- ' f " IRRIGATION EQUIPMENT LEGEND SYMBOL MANUFACTURER/MODEL It METER DETAIL A .... f'1( 1/ 11/7' DOMESTIC IRRIGATION WATER METER W/2"SERVICELINE VERIFY ACTUAL LOCATION, AND PRESSURE PRIORIN FIELD 11/2" N/A '- /`/ % I ,L f •/ TRONGBOX, MODEL ,Y MPS -A COMMENCING6-10 OK AND PURCHASING EQUIPMENT. METER ENCLOSURE SHALL BE V.I.P.R AP D EQUAV. V❑ RAINBIRD 150-EF8-CP-PRS-D (l 1/2") BRASS MASTER CONTROL VALVE WITH PRESSURE REGULATOR 1 1(2" 5010 f11V/ / /- WILKINS 375 XL 2" PLASTIC BACKFLOW PREVENTION ASSEMBLY. ALL PIPING BETWEEN METER AND BACKFLOW J / © DEVICE SHALL BE'K' COPPER OR RED BRASS. SET IN GUARD SHACK VANDAL RESISTANTSTEEL MESH 2„ 5007 FA %. ENCLOSURE OR EQUAL AS APPROVED BY THE CITY ON POURED IN PLACE CONCRETE PAD. CONTRACTOR SHALL PROVIDE PAD LOCK AND LOCK ENCLOSURE IMMEDIATELY UPON INSTALLATION. II/ DATA INDUSTRIAL 228PV3005 FLOW SENSOR, INSTALL IN VALVE BOX PER MANUFACTURER RECOMMENDATIONS 2" 5010 I❑ EZ -FLOW EZ003-CX2.5 GAL FERTILIZER INJECTOR- INSTALL PER MANUFACTURER RECOMMENDATIONS 2.5 GAL A TORO SENTINEL CONTROLLER ESB16-U2-MPEA161OK-OBI-VRA. INSTALLWITH W12 -XB TOROSENTINEL 24STATION N/A 5005 " F WIRELESS OUTPUT BOARD, LEVEL 3 SURGE PROTECTION WITH XB -SPREAD SPECTRUM RADIO. TK -3170 KENWOOD I HAND DREMOTE F F - ' CONTROLLER NSTALLATION CHARGER SET TO CITY OF LFREQUENCY OION FOR CONTACT GREEN PRODUCT SAES TO SCHEDULEMG. AFTER CERTIFICATION a 1I ' ENCLOSE IN A MPS-A16-lOK WITH A SB-24SS/120V STRONG BOX -HAND HELD RADIO CONTROLLER SHALL BE MATCHLINE A -THIS SHEET - 1_ `_ ,,, _ \� FULLY FUNCTIONAL AND TURNED OVER TO THE CITY OF FONTANA AT THE TIME OF FINAL ACCEPTANCE I,,,. -., ,L, „U ,„--. iLL%y,` //�/v:a_ INSTALL SENTINEL ANTENNA ATOP RAIN BUCKET POLE - NO RAIN BUCKET TO BE INSTALLED ..... r 1 120 VOLT ELECTRICAL POWER, PROVIDED BY ELECTRICIAN, VERIFY ACTUAL LOCATION IN FIELD N/A N/A ` A VALVE INE SIZE 5019 LARKSTONE STREET (111 11) \ O C _, H ASCO SLO CLOSE SCH. 80 PVC TRU-UNION B ALL E WITH SOLVENT WELD COCONNECTIONS, SIZE PER LINE 1,150 SATURATED TEAM ^ ^,- -°� r--` NON -RISING STEM; SCREWED BONONEET. SOLID DISC. PROVIDE WITH HANDW DE WITH SCREWED JOINTS. LINE SIZE 5019 o I �f.� Q _ NOT SHOWN WILKINS 500 HE PRESURE REGULATING VALVE R 502 LINE SIZE f - _ -.-,_ � INBIRD/33DRC QUICK COUPLER VALVE PLAN SIZE 5038 1 -� '/^-'.. �"', RAINBIRD I00-EFB-CPBRASSIN-LI N E REMOTE CONTROL VALVE 0!� I, E {BY 00D BRASS IN LINE VALVE WITH LARGE CAPACITY FILTER W A V � / � � _ � -=`. � "-� . "+ � • RAINBIRD 100-EFB-CP WITH LCR 1 3 : 1 PVC PIPE 2” CL 315 AS MAINLINES 24 BELOW GRADE- PURPLE FOR FUTURE RECYCLEDPLAN SIZE 5015 PVC.PIPE3M!'-11/2"SCHD. 40 AS LATERAL LINES I2"BELOW GRADE -PURPLE FOR FUTURERECYCLD PLAN SIZE 5015 _. W I.. I I's - A - ��/� / - —" "'—'' "`'-•-- .` a`'�`'' +.'Y_ %�,.� PVC PIPESCH.40 ASSLEEVING,TWICE THE DIAMETER OF PIPE OR WIRE BUNDLE CARRIED PLACE BELOW AL CI) I PAVING, HARDSCAPE, ETC., AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. PURPLE FOR PLAN SIZE 5018 3 J�FUTURERECYCLED Q 1I I a' 11If f f �l RAINBIRD RWS-B-C-1401 DEEP ROOT WATERING SYSTEM WITH PRESSURE REGULATOR PRS -050-30 B �I ' -�_� "y`» "' *T ;. I 12 PER TREE, LOCATE ON OPPOSITE SIDES OF TREE) GPM: 1 (PER TREE) PERCIPITATION RATE: 1.90 PSI: 30 #12"UF"COMMON WIRE -USE DBY-6 WIRE CONNECTORS FOR USE ON ALL WIRECONNECTINS 12/14 GA 5013 NOTSHOWN #14 "UV 600V IRRIGATION CONTROL WIRE 14 RAINBIRD -XFS-P-06-12-XXX DRIP TUBING W/.61 GPH EMITTERS I2"O.C. INSTALL DRIP TUBING IN ROWS AT 18" PLAN SIZE E j I I1 i I ',._ - t 11 j jl l; / _ �• III _ _ - = O.C. MAX IN ALL SHRUB AREAS. ALL TUBING SHALL BE INSTALLED 4" BELOW FINISHED MULCH. INSTALL 9" WIRE STAKES AT S'O.C. MAX. RAINBIRD RISER ASSEMBLY TEE OR EL FITTING FOR CONNECTION BETWEEN PVC LATERAL LINES AND DRIP TUBING. PLAN SIZE F RAIN EABINSTALL FLUSH ASSEMBLY A fi ROUND LVE BIRD AVAOBOXOM PAVING AND AT LOW POINT OF PLANTER PLAN SIZE C AREA, i I 1¢-'I f-9.! fl IIIIf (;If f i I + L' I � RAIN BIRD ARV050, AIR/VACUUM RELIEF VALVE, INSTALLED WITH A COMBINATION TEE. INSTALL AIR RELIEF BAIN M 0 HIP LF VA LV ES MAY BE REQUIRED EB RCV VERT Y QUANTITY RIOR O STARTINGX AT TH E IT IG IT POAC WORK, EN TALLLVALVE BOX 18" FROM PA NG AND PLAN S17E D W I - / I I 1 I f I — — . AT HIGH POINT OF PLANTER AREA. �f Z A4 I I ?i I( 111j1{ ,`I 1I1 F f ( i NOT SHOWN REMOTE CONTROL VALVE AND FLOW SENSOR BOXES SHALL BE RECTANGULAR PURPLE LOCKABLE PLASTIC BOXES I12" X 18"I AMETEK OR APPROVED EQUAL, WITH SOLID COVERS. GATE VALVE BOXES SHALL BE TEN 1 W 1 4 I f III I, , ('I : f f I OR APPROVED10"1ROU NQDp OC K AB LE PLASTIC BOXES WITH EXTERIOR AS REQUIRED TO PROPERLY PROTECT VALVE, AMETEK A- ! 1 1111 11iz f 1 I f z i" f If ,I I1I1j� 1I I['' f MATCHLINE B -THIS SHEET Q ,,= I f r =� I i If _ KEY MAP N O R T H Scale: 1"= 20' r— VALVE STATION NUMBER HYDROZONE A-5 1: HIGH 2: MED 3 1" —VALVE SIZE 3: LOW 2 G.P.M. IRRIGATION PLAN