Loading...
HomeMy WebLinkAbout5679-6F0Q � 4 14 P "10 W5 41 a N h REMOTE CONTROL VALVE SCALE: NONE ❑1 top of mulch ® 6 -inch round valve box: rain bird vb-&rnd 51 air relief valve kit: rain bird xi -1000 ar valve kit ® finish grade ® landscape dripline - black stripe tubing ® 3 -inch minimum depth of 3/4 -inch washed Gravel ❑1 30 -in linear lenght of wire, coiled ❑ water proof connection N of 2) ID tag ® valve box 12" size ❑5 remote control valve ® pvc sch. 80 nipple (close) ® pvc sch. 80 nipple (length as required) ® pvc mainline pipe sch. 80 nipple (2 -in length hidden) and sch. 40 all Im pvc sch, 40 tee/ell Ii pvc sch. 40 male adapter iZ 3 inch minimum depth of %-inch washed gravel 13 pvc lateral pipe I4 brick (I of 4) 2 E s 0- i _© remote control valve with disc filter and pry ® techline start connection male adapter and tee ❑3 pvc or poly supply header ® IS" o.c. row spacing perimeter laterals 2" to 4" from edge © techline CV dripline ❑ area perimeter ® pvc or poly exhaust header manual flush valve plumbed to pvc or poly, see detail 2, this sheet i® easy fit compression tee. rain bird mdcf tee i1 landscape dripline tubing: Netafim dripline per legend 12 tie down stake: rain bird Idl6stk NETAFIM Teehline CV ENP FEED LAYOUT SCALE: NONE 3' 15 0 0 0 m Note: 11/2 " valves may 1:31 require plastic box T -I extensions 14 COMMERCIAL CONTROL ZONE K I T F& control zone kit g pvc sch 40 male adapter pvc lateral Im pvc sch. 80 nipple, close (I of 3) ii pvc sch 80 union for servicing assembly 12 brick (I of 4) 13 pvc mainline 14 3 -inch minimum depth of 3/4 -inch washed gravel 15 pvc sch 80 nipple (2 -Inch length, hidden) and pvc sch 40 all i� pvc sch 40 tee or all ❑I clean backfill - see specs for material SO% compaction required non -pressure lateral line snake pipe in trench control wires - bundle and tape at 10' oc, and install adjacent to pressure supply line ® proved 2" of clean backfill ❑5 pressure supply line snake pipe in trench NOTE: PI&TAIL AND LOOP CONTROL WIRE AT ALL cIO DESREE CHANSED IN DIRECTION TRENCHIN6 NOTES: PLACE PEA &RAVEL PRIOR TO INSTALLATION OF VALVE BOX &ATE VALVE SHALL BE INSTALLED IN SHRUB AREAS UNLE55 OTHERWISE APPROVED &ATE VALVE SCALE: NONE AS READ. ❑1 gate valve approved valve box I" In lawn areas 2' planter areas ® pvc male adaptor tsp. two places ® pressure main line angle to specified depyh with 45 -degree elbows, size per drawings. ® brick supports (three required) ❑1 pea gravel 3/4" dia. 3" deep I 1❑ concrete pad pea gravel F ® strongbox, or equal 2 solidvandal resistant enclosure. size as �� _ — — — — — _ — - necessary ® polar bearier slip-on insulating cover. a size as necessary 1 wye strainer z I (if required) s I I 5 13 ® rp. backflow I preventer g 9 brass union (2) WATER TER A55EMBLY ® brass pipe length as required 1 pvc sch. 80 male adapter 10 pressure supply line (discharge) 12 11 Im II brass elbow NOTES: 12 rigid pipe EQUIPMENT TO BE INSTALLED AT A MINIMUM OF 24" FROM pressure supply WALLS, BUILDIN&5, ETC. INSTALL BACKFLOW DEVICE ON line (intake) OR SHRUB AREAS ONLY. PROVIDE RI&ID PIPE, BEFORE BACKFLOW 13 pressure regulator R.P. BACKFLOW PREVENTOR w/ ENCLOSURE FLUSH VALVE ❑J 6" round plastic valve box OU I CK COUPLER note: 18" RUB for 15 gal -24" box trees 36" RWS for 36" box trees and larger ROOT AATERIN6 5Y5TEM ❑2 mulch/ground cover per planting plan Msch 40 pvc nipple ® pvc ball valve to rest on gravel sump ❑5 2 cu. ft crushed agg. sump ® sch 40 pvc s x t coupling lateral line - cover as noted on legend WIT �, � ❑1 approved valve box and cover aquick -coupling valve ❑3 pvc sch. 80 nipple (length as regired) ® pea gravel, 3/a" dia. 3" deep ® brick (I of 2) ® pvc sch. 40 street ell ® pvc sch. 80 nipple (length as required) ® pvc sch. 40 tee or all pvc mainline pipe 1® pvc sch. 40 all ii 04 rebar stake 24" long w/ stainless steel gear clamps or equivalent support system E] 4" grate (included) bubbler: rainbird 1402 (090 Qpm) (included) 10 pea gravel, 3/4" dia. (optional) or rws sand sock (rws-sock) for sandy soils ® Ya" pvc sch 80 nipple (included) ❑5 v" 90' elbow (included) ® 12" swing assembly (included) ® Y" male npt inlet (included) ® pvc sch. 40 tee or ell lateral pipe i® 4" basket weave canister (included) ION DETAI pvc sch 40 ell ® water proof pvc sch 80 nipple connection: (i of 2) (typical, length as® valve box with cover required) El30 -inch linear length © ID tag. rain bird vid of wire, tolled series 0 0 0 m Note: 11/2 " valves may 1:31 require plastic box T -I extensions 14 COMMERCIAL CONTROL ZONE K I T F& control zone kit g pvc sch 40 male adapter pvc lateral Im pvc sch. 80 nipple, close (I of 3) ii pvc sch 80 union for servicing assembly 12 brick (I of 4) 13 pvc mainline 14 3 -inch minimum depth of 3/4 -inch washed gravel 15 pvc sch 80 nipple (2 -Inch length, hidden) and pvc sch 40 all i� pvc sch 40 tee or all ❑I clean backfill - see specs for material SO% compaction required non -pressure lateral line snake pipe in trench control wires - bundle and tape at 10' oc, and install adjacent to pressure supply line ® proved 2" of clean backfill ❑5 pressure supply line snake pipe in trench NOTE: PI&TAIL AND LOOP CONTROL WIRE AT ALL cIO DESREE CHANSED IN DIRECTION TRENCHIN6 NOTES: PLACE PEA &RAVEL PRIOR TO INSTALLATION OF VALVE BOX &ATE VALVE SHALL BE INSTALLED IN SHRUB AREAS UNLE55 OTHERWISE APPROVED &ATE VALVE SCALE: NONE AS READ. ❑1 gate valve approved valve box I" In lawn areas 2' planter areas ® pvc male adaptor tsp. two places ® pressure main line angle to specified depyh with 45 -degree elbows, size per drawings. ® brick supports (three required) ❑1 pea gravel 3/4" dia. 3" deep I 1❑ concrete pad pea gravel F ® strongbox, or equal 2 solidvandal resistant enclosure. size as �� _ — — — — — _ — - necessary ® polar bearier slip-on insulating cover. a size as necessary 1 wye strainer z I (if required) s I I 5 13 ® rp. backflow I preventer g 9 brass union (2) WATER TER A55EMBLY ® brass pipe length as required 1 pvc sch. 80 male adapter 10 pressure supply line (discharge) 12 11 Im II brass elbow NOTES: 12 rigid pipe EQUIPMENT TO BE INSTALLED AT A MINIMUM OF 24" FROM pressure supply WALLS, BUILDIN&5, ETC. INSTALL BACKFLOW DEVICE ON line (intake) OR SHRUB AREAS ONLY. PROVIDE RI&ID PIPE, BEFORE BACKFLOW 13 pressure regulator R.P. BACKFLOW PREVENTOR w/ ENCLOSURE FLUSH VALVE ❑J 6" round plastic valve box OU I CK COUPLER note: 18" RUB for 15 gal -24" box trees 36" RWS for 36" box trees and larger ROOT AATERIN6 5Y5TEM ❑2 mulch/ground cover per planting plan Msch 40 pvc nipple ® pvc ball valve to rest on gravel sump ❑5 2 cu. ft crushed agg. sump ® sch 40 pvc s x t coupling lateral line - cover as noted on legend WIT �, � ❑1 approved valve box and cover aquick -coupling valve ❑3 pvc sch. 80 nipple (length as regired) ® pea gravel, 3/a" dia. 3" deep ® brick (I of 2) ® pvc sch. 40 street ell ® pvc sch. 80 nipple (length as required) ® pvc sch. 40 tee or all pvc mainline pipe 1® pvc sch. 40 all ii 04 rebar stake 24" long w/ stainless steel gear clamps or equivalent support system E] 4" grate (included) bubbler: rainbird 1402 (090 Qpm) (included) 10 pea gravel, 3/4" dia. (optional) or rws sand sock (rws-sock) for sandy soils ® Ya" pvc sch 80 nipple (included) ❑5 v" 90' elbow (included) ® 12" swing assembly (included) ® Y" male npt inlet (included) ® pvc sch. 40 tee or ell lateral pipe i® 4" basket weave canister (included) ION DETAI