Loading...
HomeMy WebLinkAbout4986-33r,.. , Drl ve way z 14 R26(S)(CA) Driveway Etiwanda Ave R 1 Ln JOIN EXISTING STRIPING STA. 0-15 CURB O N — 14- _1+00 -1+00 0+00- 1+00 2+00 CITY OF ONTARIO 3+00 N - - CITY OF FONTANA - - LO `�cn ^/ W ro JOIN EXISTING STRIPING STA. 1+40 CURB Driveway SEE SHEET 1 FOR STRIPING i*Tpo r rive i TYPE I VI 3 5 TYPE I 7 5 _ ,,#'' �::• fib. • i .: � •t'! - ...................I .............................-. .....-....-.-.. ' �...--- --. ............................... I ". .....-. ----------/ 600' CURB TAPER 200' R4-1 14 4 14 R26(S)(CA) 14 W4-2 14 WI , 4 2 4 R26(S)(CA\ Driveway ........ ��� �N�� ��--_-_-- .......... .................................� - _ .� ��M - �...i..................� . �f - - �. ............. ....... ...... ... ..� R4 7JTYPE K(CA) .- Q R6 1(Rt) •` — — — — — — CD — — N 6 —_ �n 4_ , 18 100 BEGIN TAPER " - o `CN • • 6 1 R61 1' 1 _ - C 4+00 5+0 6+00 7+00 1 +00 - 11 +�J N - -i- - - --+- - - - - -- �. - - - - - - - - -r--- -+ - _ 7 04 TYPE IV(L) 5 N TYPE IV(L) 5 END TAPER rl 19 N 17 `��' 100' I N — -----� 18 N .... • / \ Z' .. -� ............................� ............ _ _ ................... - - -- --- k \\ 18 4r 4- % I 1 R26(S)(CA) 14 R61 C / \ TYPE IV(R) 3 195 \ 5 15 15 \ TYPE IV(R) h h R14-1 R4-7/ 15 R26{S)(CA) 2 TYPE K(CA) 14 R3-7/ R26(S)(CA) Airport Drive Et l wa n d a A Ve SCE EASEMENT � - ' " " L� ••••• L�I';rV N IN 1�I aRa 1 I I I I I �1 1► R61 D TYPE IV(R) + Z W 1 Q. < z o Z w0 i m III - SEE SHEET 1 FOR STRIPING SIGNING AND' STRIPING CONSTRUCTION NOTES: Slover venue o WET SANDBLAST AND REMOVE ALL EXISTING STRIPES AND PAVEMENT MARKINGS. SIGNING AND STRIPING GENERAL NOTES: F2] INSTALL 4" LANE LINE OR (50' SOLID LANE LINE AT INTERSECTION) WITH RAISED PAVEMENT MARKERS PER STATE STANDARD PLAN A20A, DETAIL 12. 1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT Q3 INSTALL 8" WHITE CHANNELIZING LINE PER STATE STANDARD PLAN A20D, DETAIL 38. ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT ® INSTALL TYPE VI LANE DROP ARROW AT 100' O.C. PER STATE STANDARD PLAN A24A. LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. INSTALL TYPE IV (L OR R) PAVEMENT MARKING ARROWS PER STATE STANDARD PLAN A24A AS INDICATED. CALL (909) 350-7610. Q5 2. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, DETAILS, DIMENSIONS, AND INSTALL 4" DOUBLE YELLOW LINE WITH RAISED PAVEMENT MARKERS PER STATE STANDARD PLAN A20A, DETAIL 22 OR PROCEDURES DESCRIBED IN THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND © DETAIL 29 AS SHOWN. HIGHWAYS, DATED SEPTEMBER 2006.�7 INSTALL 12„ WIDE SOLID WHITE CROSSWALK OR LIMIT LINE PER CITY OF FONTANA PLAN No. 1006. 3. CONTACT TRAFFIC ENGINEERING PROJECT MANAGER AT (909) 350-7610 TWO WORKING DAYS PRIOR TO REMOVAL OF TRAFFIC CONTROL DEVICES OR EQUIPMENT. STOP SIGNS SHALL ONLY BE REMOVED BY CITY PERSONNEL. ® INSTALL TWO-WAY LEFT TURN LANES PER STATE STANDARD PLAN A206, DETAIL 32. 4. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS, THE R9 INSTALL 24” WHITE STOP LINE PER CALTRANS MUTCD, FIGURE 88-6(CA) 15' CLEAR OF CLOSEST TRACK. STANDARD SPECIFICATIONS FOR THE CITY OF FONTANA, AND CITY OF ONTARIO, THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS, DATED SEPTEMBER 2006. R10 INSTALL RAILROAD CROSSING SYMBOL PER STATE STANDARD PLAN A24C. 5. TWO WORKING DAYS NOTICE SHALL BE GIVEN TO THE CITY OF FONTANA TRAFFIC ENGINEER (909) 350-7610, CITY OF 11 INSTALL PAVEMENT MARKINGS WORDS PER STATE STANDARD PLAN A24D OR A24E AS INDICATED. ONTARIO (909)295-2155 FOR APPROVAL OF CONTROL POINTS OR "CAT TRACKING" PRIOR TO APPLICATION OF 12 PAINT 4" WHITE LANE LINE EXTENSIONS THROUGH INTERSECTIONS PER STATE STANDARD PLAN A20D, DETAIL 40. PAVEMENT STRIPING. 6. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS, UNLESS OTHERWISE SHOWN ON PLANS. 13 INSTALL 4" WHITE RIGHT EDGELINE PER STATE STANDARD PLAN A206, DETAIL 276. 7. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY 14 INSTALL ROAD SIGN AND POST AS SHOWN. R61 SIGNS USE 2-4"x6" WOOD POSTS. OF FONTANA STANDARD DETAIL 4003. FOR 5' WIDE SIDEWALKS LOCATE SIGNS AT BACK OF WALK. 15 RELOCATE EXISTING ROAD SIGN AND/OR POST AS SHOWN. 8. STENCILS USED FOR PAVEMENT MARKINGS SHALL MATCH CITY OF FONTANA STANDARD STENCILS. 9. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED. 16 REMOVE EXISTING SIGNS. 10.CROSSWALKS SHALL HAVE 10' BETWEEN THE CENTERLINE OF THE 12" STRIPES UNLESS OTHERWISE SHOWN ON PLANS, F171 INSTALL TYPE "H" RPM'S PER DETAIL 26. PER CITY STANDARD DETAIL 1003. 18 INSTALL TYPE 1 (18') ARROW PER STATE STANDARD PLAN A24A WITH 100' SPACING. 11. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTODESK CAD FILES, TO THE CITY TRAFFIC ENGINEER. 19 INSTALL 12" WHITE DIAGONAL LINES AT 30' O.C. AS SHOWN. 12. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED, SHALL BE BY SANDBLASTING. 13.SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR TYPE "G" MARKERS ON DETAIL -38 ON HIGHWAYS WITH RAISED MEDIANS. SHOULD CONSTRUCTION OF TI• 14. BLUE DOT MARKERS (BLUE R.R.P.M.) ARE TO BE INSTALLED AT ALL FIRE IMPROVEMENTS NOT COMMENCE HYDRANT LOCATIONS PER CITY STANDARD PLAN. APPROVED CITY OF ONTARIO - .► YFARq nF TNF nATF nF APPRnVAI 13 EA. TYPE F CLASS 2 DELINEATORS 0 75' O.C. (TYP) LEGEND EXISTING SIS Slower Avenue BRIDGE DECK PROPOSED A. 19+00 1) I'll r ONLY ONLY ONLY ONLY ONLY 2-4"x6" WOOD POSTS SS -2 R61—C(93"00") R61—D(79"x30") North 1" =40' PAVEMENT ARROW -O STREET LIGHT LUMINAIRE F ROAD SIDE SIGN TRAFFIC STRIPE OR MARKING S1U PAVEMENT LEGEND A. 19+00 1) I'll r ONLY ONLY ONLY ONLY ONLY 2-4"x6" WOOD POSTS SS -2 R61—C(93"00") R61—D(79"x30") North 1" =40'