Loading...
HomeMy WebLinkAbout5614-1TRACT N0. 19962 WATER QUALITY MANAGEMENT PLAN STORM DRAIN IMPROVEMENT PLANS IN THE CITY OF FONTANA, COUNTY OF SAN BERNARDINO, STATE OF CALIFORNIA 0 0 NMI LIST OF LID BMPS STORMWATER RUNOFF AND NUISANCE FLOWS WILL BE INTERCEPTED BY EITHER GRATED CATCH BASINS A WITHIN THE GUTTER OR LOW FLOW DIVERSION MANHOLES AND CARRIED VIA 24" RCP TO CYPRESS AVENUE. FROM THERE, FLOWS WILL TRAVEL TO SIERRA LAKES GOLF COURSE FOR TREATMENT AND INFILTRATION DRAINAGE WATER QUALITY CONSTRUCTION NOTES AREA DCV Qbmp INSTALL JENSEN PRECAST 24"X24" DRAIN INLET PER DETAIL SHEET 6 - - - - - - AREA (SF) SHEET INDEX O2 INSTALL 18" RCP STORM DRAIN (D -LOAD PER PROFILE) - - - - - - - - - - - AREA TITLE - DRAINAGE AREAS 1 (ACRES) (CF) (CFS) DA1 1,324,479 30.4 83,720 4.42 VICINITY MAP NOT TO SCALE NOTES: 1. SIERRA LAKES GOLF COURSE TO TREAT WATER QUALITY FLOWS FROM MULTIPLE DEVELOPMENTS IN NORTHERN FONTANA 2. THIS PLAN SHOWS THE TREATMENT AREA BOUNDARY FOR THE WATER QUALITY STORM DRAIN WITHIN TRACT 19962 3. LOT A STRUCTURAL BMP PER PLAN AND PROFILE FROM TRACT 19960 WATER QUALITY MANAGEMENT PLAN III=III= i j / N 1"MAX. SIZE SELECTED NATIVE BEDDING COMPACTED TO 90% NOTES: 1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE 2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE ADEQUATE SHORING. 3. CLASS II AGG.BASE ALL TRENCHES LESS THAN 1 00'IN LENGTH. NOTE: COMPACTION SHALL BE 90% IN ALL ZONES UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM TO CAL -OSHA REQUIREMENTS. TOP OF STRUCTURAL PVM'T. SUBGRADE 3" MAX. SIZE NATIVE SOIL COMPACTED 95% 1:1 SLOPE OR FLATTER OR ADEQUATE SHORING 90% COMPACTED—, NATIVE BACKFILL 6" MAX. SIZE 6" MIN. z III 8" MAX. J it =_ 6-0 HE Q STORM DRAIN PIPE BEDDING MATERIAL SHALL MEET OR EXCEED SECTION 306-1.2.1, STD. SPECS FOR PUBLIC WORKS CONSTRUCTION, LATEST EDITION. LOCALLY EXCAVATED NATIVE MATERIALS MAY BE BLENDED TO THE REQUIRED SAND EQUIVALENCY OF 30 OR GREATER ,0 I 6" MIN. 1 8" MAX. WATER QUALITY CONSTRUCTION NOTES J J O INSTALL JENSEN PRECAST 24"X24" DRAIN INLET PER DETAIL SHEET 6 - - - - - - - - 15 EA SHEET INDEX O2 INSTALL 18" RCP STORM DRAIN (D -LOAD PER PROFILE) - - - - - - - - - - - - 259 LF TITLE - DRAINAGE AREAS 1 O3 INSTALL 24" RCP STORM DRAIN (D -LOAD PER PROFILE ( )------------ 1,799 LF LINE WQA 2 LINE WQB 3 III o LINE WQC AND WQD 4 O CONSTRUCT STORM DRAIN MANHOLE PER CITY OF FONTANA STD PLAN NO. 3013 - - - - 9 EA LINE WQE AND WQF 5 O- CONSTRUCT JUNCTION STRUCTURE PER CITY OF FONTANA STD PLAN NO 3010 - - - 9 EA DETAILS 6 O CONSTRUCT CONCRETE COLLAR PER CITY OF FONTANA STD PLAN NO 3022 - - - - 8 EA O CONSTRUCT TRANSITION STRUCTURE PER CITY OF FONTANA STD PLAN NO 3026 - - - - 2 EA O INSTALL FLOGARD CATCH BASIN FILTER PER DETAIL SHT 6 (CFD) _ - - - - - - - _ 15 EA O CONSTRUCT MODIFIED JUNCTION STRUCTURE PER PLAN AND PROFILE AND _ - - - _ 1 EA CITY OF FONTANA STD PLAN. NO. 3026 10 REMOVE EXIST. PIPE CLOSURE. _------------------_ 1 E 11 CONSTRUCT CONCRETE TRENCH BACKFILL _ - - - - - - - - - - - - - - _ 66 SF NOTES: 1. SIERRA LAKES GOLF COURSE TO TREAT WATER QUALITY FLOWS FROM MULTIPLE DEVELOPMENTS IN NORTHERN FONTANA 2. THIS PLAN SHOWS THE TREATMENT AREA BOUNDARY FOR THE WATER QUALITY STORM DRAIN WITHIN TRACT 19962 3. LOT A STRUCTURAL BMP PER PLAN AND PROFILE FROM TRACT 19960 WATER QUALITY MANAGEMENT PLAN III=III= i j / N 1"MAX. SIZE SELECTED NATIVE BEDDING COMPACTED TO 90% NOTES: 1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE 2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE ADEQUATE SHORING. 3. CLASS II AGG.BASE ALL TRENCHES LESS THAN 1 00'IN LENGTH. NOTE: COMPACTION SHALL BE 90% IN ALL ZONES UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM TO CAL -OSHA REQUIREMENTS. TOP OF STRUCTURAL PVM'T. SUBGRADE 3" MAX. SIZE NATIVE SOIL COMPACTED 95% 1:1 SLOPE OR FLATTER OR ADEQUATE SHORING 90% COMPACTED—, NATIVE BACKFILL 6" MAX. SIZE 6" MIN. z III 8" MAX. J it =_ 6-0 HE Q STORM DRAIN PIPE BEDDING MATERIAL SHALL MEET OR EXCEED SECTION 306-1.2.1, STD. SPECS FOR PUBLIC WORKS CONSTRUCTION, LATEST EDITION. LOCALLY EXCAVATED NATIVE MATERIALS MAY BE BLENDED TO THE REQUIRED SAND EQUIVALENCY OF 30 OR GREATER ,0 I 6" MIN. 1 8" MAX. III— 111 - TYPICAL RCP TRENCH DETAIL NOT TO SCALE NOTE: THE CONTRACTOR SHALL POTHOLE PRIOR TO ANY CONSTRUCTION WORK ALL EXISTING UTILITIES OF POSSIBLE CONFLICT & THE POINTS OF CONNECTION TO VERIFY THE LOCATION AND ELEVATION. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY OF ANY CONFLICTS AND/OR DISCREPANCIES. OWNER/DEVELOPER NORTH FONTANA INVESTMENT COMPANY, LLC 1156 NORTH MOUNTAIN AVENUE UPLAND, CA 91786 CONTACT: STACEY SASSAMAN ENGINEER MADOLE & ASSOCIATES, INC 9302 PITTSBURGH AVENUE, #230 RANCHO CUCAMONGA, CA 91730 (909) 481-6322 CONTACT: MARK BERTONE WOMP17-0000041 N co N N I co N r J J Lu m III o m � III— 111 - TYPICAL RCP TRENCH DETAIL NOT TO SCALE NOTE: THE CONTRACTOR SHALL POTHOLE PRIOR TO ANY CONSTRUCTION WORK ALL EXISTING UTILITIES OF POSSIBLE CONFLICT & THE POINTS OF CONNECTION TO VERIFY THE LOCATION AND ELEVATION. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY OF ANY CONFLICTS AND/OR DISCREPANCIES. OWNER/DEVELOPER NORTH FONTANA INVESTMENT COMPANY, LLC 1156 NORTH MOUNTAIN AVENUE UPLAND, CA 91786 CONTACT: STACEY SASSAMAN ENGINEER MADOLE & ASSOCIATES, INC 9302 PITTSBURGH AVENUE, #230 RANCHO CUCAMONGA, CA 91730 (909) 481-6322 CONTACT: MARK BERTONE WOMP17-0000041 N co N N I co N r