HomeMy WebLinkAbout5612-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE
CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN
BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS
OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL
IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER
TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5
FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY
SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF
THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET
SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE
THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO
WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY
COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE
AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR
VALVE OPERATION AND WATER REQUIREMENTS.
13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS
WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT
TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED.
THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO
MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES.
19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED
ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT
PRIOR WRITTEN APPROVAL.
20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED
DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS
OBTAINED.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING
CONCRETE.
24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL
CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWN STREAM MANHOLE, SEE
CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY
PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION
C700 FOR V.C.P..
26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY
ENGINEER.
27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR
MINOR DEFLECTIONS IN ALIGNMENT.
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION
AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT
IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS,
29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY
THE CITY ENGINEER.
30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND
SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT-OF-WAY, THE LATERAL
SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER
LATERAL.
32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
33, NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT.
36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY
THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES,
AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL
PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER,
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE
BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN
ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE
CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY
PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY;
THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING
HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER
AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN
CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR
LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL
DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER OF ANY
DISCREPANCIES. BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS.
CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS.
CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER VALVE
BOXES, UTILITY BOXES AND LIDS, ETC.
CONTRACTOR SHALL PROVIDE ALL THE NECESSARY PIPE FITTINGS TO COMPLETE THE
WORK.
THE ENGINEER PREPARING THESE PLANS SHALL NOT BE HELD RESPONSIBLE OR LIABLE
FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THESE
PLANS MUST BE REQUESTED IN WRITING AND MUST BE APPROVED BY THE ENGINEER OF
RECORD.
QUANTITIES SHOWN HEREON ARE PROVIDED FOR PERMIT AND BONDING PURPOSES
ONLY. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THEIR OWN QUANTITIES
PRIOR TO BIDDING AND CONSTRUCTION. THE ENGINEER IS NOT RESPONSIBLE FOR
DISCREPANCIES IN FINAL CONSTRUCTION QUANTITIES.
Lei I &To] 2 1 If, I mv mint
IN -TRACT SEWER IMPROVEMENT PLANS
TRACT NO,19962, 1^w^62-1 AND 1^w^62-2
I 25
3 o Il-'(1� 7(� � � � 0 Q 28
Wl� 68 27 26 _
37 36 35
69
- 4 2 �- - ----
116 a I Ing od 2 1
LOT 'A� I'III IIIJill
IV IN E 1 �-
PARK Ir
40 71.
53. 18
_ z
7 fI 133 -; '� 71, r - 154 47T 19
31 a I 78 55 46 10 1
2 1 8 1 28 I I53 n
1 56 4510 11
9 O 1 35 29 152 1
1 0 761 157 44 F= 112
1 110 3631 58 43 0 13
LANE 1 fl 1 371 74
M
32 159 I 114
��0�� 112 38 331 1 48 731 160 41 115 1
SCHOOL WE L1I 13 39 34 O 147 72 1 61 40 CQ 1693
w
14 40 35 46 71 1 62 39I� 117
5� 1 15 32 1 41 45 701 1 63 381
1 U
16 1 42 1 44 43 64 37 19
>7 143 142 I 165 361
361- h
522 I �_
Nil I
51
50 49 48 47 46 45 34 33 32 31 30 29 177 267.
25 24
--------t--1--------------
-- - ----
EASA A:'DE- .�� - - -
INDEX MAP
PL PL
3' MIN.
I 5' MIN.
RIW I PROP. 5' SIDEWALK 3MIN.
CURB LINE 5' MIN. SEWER LATERAL
WATER MAIN W WATER SERVICE METER
0
SEWER MAIN N `n
S
TYPICAL SEWER LATERAL AND WATER SERVICE DETAIL
NOT TO SCALE
TOP OF STRUCTURAL
NOTES: PAVEMENT SUBGRADE
1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE 6" MIN.
ZONE. 10" MAX.
2. TRENCH DEPTHS OF GREATER THAN 5SHALL HAVE
ADEQUATE SHORING.
3. CLASS II AGG. BASE ALL TRENCHES LESS THAN 100' IN
LENGTH.
4. COMPACTION SHALL BE 90% IN ALL ZONES UNLESS 6" MAX. SIZE
OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM NATIVE SOIL
TO CAL -OSHA REQUIREMENTS. COMPACTED 90%
5. THE SEWER PLUMBER TO VERIFY THE ULTIMATE BACKFLOW
PREVENTION VALVE. 8" V.C.P.
d �
BEDDING MATERIAL SHALL MEET OR EXCEED SECTION
306-1.2.1, STD. SPECS FOR PUBLIC WORKS
CONSTRUCTION, LATEST EDITION. LOCALLY EXCAVATED
NATIVE MATERIALS MAY BE BLENDED TO THE REQUIRED
SAND EQUIVALENCY OF 30 OR GREATER
TOLL FREE 811
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
REVISION DESCRIPTION
3" MAX. SIZE NATIVE
SOIL COMPACTED 95%
6" MIN.
10" MAX.
-1:1 SLOPE OR FLATTER
OR ADEQUATE SHORING
1" MAX. SIZE SELECTED
NATIVE BEDDING
COMPACTED TO 90%
TYP. BEDDING FOR 8" VCP
LESS THAN 10' DEEP
NTS
Iz
DATE I ENGR. I CITY I DATE
SCALE:1 "=200'
NORTH OR WEST SOUTH OR EAST
R/W R/W
60'
CL
0.5' 1 5' 1 4.5' 1 20' 1 20' 1 4.5' 1 5' 1 0.5'
_J 71
1- PROP. SEWER
O
PROP. SD
TYPICAL UNDERGROUND UTILITY LOCATION
SCALE: 1 "=10'
SEWER-
CABLE:
CITY OF FONTANA
TIME WARNER CABLE
8353 SIERRA AVENUE
1205 DUPONT AVENUE
FONTANA, CA 92335
ONTARIO, CA. 91761
PHONE: 909.350.6632
PHONE: 909.390.4738
GAS;
TELEPHONE:
SOUTHERN CALIFORNIA GAS COMPANY
AT&T
16231 VALLEY BLVD.
11464 TELEGRAPH ROAD
FONTANA, CA 92335
SANTA FE SPRINGS, CA 90670
PHONE: 909.428.8411
PHONE: 714.666.5415
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT
MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO
CONFORMANCE WITH CONDMONS AND STANDARDS IN EFFECT.
VICINITY MAP
NOT TO SCALE
>t.r�MUT 1wki
AC
ASPHALTIC CONCRETE
R/W
RIGHT OF WAY
BC
BEGIN CURVE
TAN
TANGENT
BVC
BEG. VERTICAL CURVE
TC
TOP OF CURB
BW
BACK SIDEWALK
W
WIDTH
CB
CATCH BASIN
V
VERTICAL DEPTH
CL
CENTERLINE
(590.69)
EXISTING ELEVATION
EC
END CURVE
590.96
PROPOSED ELEVATION [590.691
EP
EDGE PAVEMENT
DRAWN BY:
FUTURE ELEVATION
EG
EDGE GRADE
PHONE 909.481.6322
EVC
END VERTICAL CURVE
�r Exp: 06-30-18
SLOPE
FL
FLOW LINE
0
AC PAVEMENT
FS
FINISH SURFACE
WLI
GB
GRADE BREAK
REMOVAL
HP
HIGH POINT
GRIND
INV
INVERT
OC
ON CURVE
EDGE OF PAVEMENT
PL PROPERTY LINE
PCC PORTLAND CEMENT CONCRETE
(R) RIDGE LINE
CONSTRUCTION NOTES QUANTITIES
10
INSTALL 8" EXTRA STRENGTH V.C.P. SEWER
4037 L.F.
(
INSTALL 10" EXTRA STRENGTH V.C.P. SEWER
2394 L.F.
O3
CONSTRUCT 48" PRECAST CONCRETE MANHOLE PER CITY OF FONTANA
CASA GRANDE AVENUE AND SIERRA AVENUE.
STD. DWG. NO'S. 2000, 2001 & 2003
15 EA
40
CONSTRUCT 60" PRECAST CONCRETE MANHOLE PER CITY OF FONTANA
ELEVATION: 1739.006'
STD. DWG. NO'S. 2000, 2001 & 2003
8 EA
O5
INSTALL 4" V.C.P. SEWER LATERAL AND CLEANOUT BOX PER CITY OF
QROFESS/n
L. /!q �F
FONTANA STD. DWG. NO. 2005.
6782 L.F.
O6
INSTALL BACKWATER VALVE DEVICE
135 EA
ELECTRIC:
SOUTHERN CALIFORNIA EDISON COMPANY
7951 REDWOOD AVE.
FONTANA, CA. 92336 OWNER/DEVELOPER:
PHONE: 909.357.6221 NORTH FONTANA INVESTMENT COMPANY, LLC
WATER: 1156 N. MOUNTAIN AVE.
WEST VALLEY WATER DISTRICT UPLAND, CA 91786-0670
855 W. BASELINE ROAD PHONE: 909.985.0971
RIALTO, CA 92377 CONTACT: STACEY SASSAMAN
PHONE: 909.875.1361
BENCH MARK: # 8.7
BASIS OF BEARINGS:
SAN BERNARDINO COUNTY BENCHMARK # 6-7.
THE CENTERLINE OF CITRUS AVENUE AS
A BRASS DISK AT THE SOUTHEAST CORNER OF
SHOWN ON RECORD OF SURVEY 35/9 TAKEN
CASA GRANDE AVENUE AND SIERRA AVENUE.
AS N 01'10'30" W WAS USED AS THE BASIS
OF BEARINGS FOR THIS MAP.
ELEVATION: 1739.006'
PREPARED UNDER THE SUPERVISION OF:
QROFESS/n
L. /!q �F
(4MADOLEG
9302 PITTSBURGH AVE., SUITE 230
DRAWN BY:
Nocy-. 36637 C
RANCHO CUCAMONGA, CA. 91730
IES, INC.
DM 1 EH
PHONE 909.481.6322
DESIGNED BY:
�r Exp: 06-30-18
En ineerin Communities for Life FAX 909.481.6320
sq/V1� ��P
-7
GBISCL
CHECKED BY:
FCAL�F
DA v�
WLI
ENDELL.I TSURU EXP6-30-. 1
ENGINEER:
MADOLE AND ASSOCIATES, INC.
9302 PITTSBURGH AVE., SUITE 230
RANCHO CUCAMONGA, CA 91730
PHONE: 909.481.6322
FAX: 909.481.6320
CONTACT: MARK BERTONE
CITY OF FONTANA, CALIFORNIA
IN -TRACT SEWER IMPROVEMENT PLANS
TITLE SHEET SCALE:
AS SHOWN
TRACT N0.19962, 19962-1, & 19962-2 DATE:
NOV. 2016
APPROVED-3Y� ,� DRAWING N0.
� �,•�jita'f 6/11 /17
CITY ENGINEER R.C.E. 51152 DATE 5612
J:\126-2659\sewer\TR 19962\Sew0l.dwg, 4/26/2017 10:52:28 AM, DWG To PDF.pc3