HomeMy WebLinkAbout5586A-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
("GREEN BOOK") AND THE STATE OF CALIFORNIA D.O.T. STD. SPEC'S AND PLANS. ALL REFERENCE
SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK
PRIOR TO IMPLEMENTING DETOURS.
5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK, INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES
5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS
THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER,
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE
LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO
AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTRACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT
NOT LIMITED TO GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS, ALL
UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR
FACILITIES.
13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER
COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING
CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED
LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO
CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE
MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES.
20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION, FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
CITY OF FONTANA
GARDENS STREET WATER QUALITY STORM DRAIN
GRASSLAND AVENUE
TIN kC7 19 6
24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE.
25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE
CITY ENGINEER.
26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION
AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT
IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
28 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OR
STREETS.
30. APPROVED SOILS STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE
BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY
TRAFFIC ENGINEER.
33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
34. "THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONCRETE PIPES MUST
BE INCREASED TO PROVIDE A MINIMUM OF 1-1/2" OVER THE REINFORCING WHEN THE
DESIGN VELOCITIES EXCEED 20 FEET PER SECOND. THE CONCRETE DESIGN STRENGTH
IN THESE REACHES SHALL BE fc=5,000 psi FOR VELOCITIES EXCEEDING 20 FEET PER
SECOND AND fc=6,000 psi FOR VELOCITIES EXCEEDING 30 FEET PER SECOND."
35. MINIMUM D -LOAD FOR ALL R.C.P. IS 1350.
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE
OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING
UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL
LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON
THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE
CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT
THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING
FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE
ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY
THE ENGINEER OF ANY DISCREPANCIES. BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS.
CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS.
CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER VALVE BOXES, UTILITY BOXES AND LIDS,
ETC.
CONTRACTOR SHALL PROVIDE ALL THE NECESSARY PIPE FITTINGS TO COMPLETE THE WORK.
THE ENGINEER PREPARING THESE PLANS SHALL NOT BE HELD RESPONSIBLE OR LIABLE FOR UNAUTHORIZED
CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THESE PLANS MUST BE REQUESTED IN WRITING AND MUST
BE APPROVED BY THE ENGINEER OF RECORD.
QUANTITIES SHOWN HEREON ARE PROVIDED FOR PERMIT AND BONDING PURPOSES ONLY. CONTRACTOR SHALL BE
RESPONSIBLE FOR DETERMINING THEIR OWN QUANTITIES PRIOR TO BIDDING AND CONSTRUCTION. THE ENGINEER IS
NOT RESPONSIBLE FOR DISCREPANCIES IN FINAL CONSTRUCTION QUANTITIES.
GRASSLAND AVENUE
INDEX MAP
SCALE:1 "=100'
CYPRESS AVENUE
III -III-
1"MAX. SIZE SELECTED
NATIVE BEDDING
COMPACTED TO 90% _
NOTES:
1. TRENCH WIDTH SHALL BE
CONTROLLED TO TOP OF PIPE
ZONE.
2. TRENCH DEPTHS OF GREATER
THAN 5' SHALL HAVE ADEQUATE
SHORING.
3. CLASS II AGG.BASE ALL TRENCHES
LESS THAN 100' IN LENGTH.
NOTE:
COMPACTION SHALL BE 90% IN ALL
ZONES UNLESS OTHERWISE SPECIFIED.
TRENCH STABILITY SHALL CONFORM TO
CAL -OSHA REOUIREMENTS.
0
0
II
L�
Q
U
TOP OF STRUCTURAL
PVM'T. SUBGRADE
3" MAX. SIZE NATIVE SOIL
COMPACTED 95%
1:1 SLOPE OR FLATTER OR
ADEQUATE SHORING
-90% COMPACTED
NATIVE BACKFILL
6" MAX. SIZE
STORM DRAIN PIPE
BEDDING MATERIAL SHALL MEET OR EXCEED SECTION
306-1.2.1, STD. SPECS FOR PUBLIC WORKS
CONSTRUCTION, LATEST EDITION. LOCALLY EXCAVATED
NATIVE MATERIALS MAY BE BLENDED TO THE REQUIRED
SAND EQUIVALENCY OF 30 OR GREATER
=III
6"MIN. III =
8" MAX. = I I I
III=
III m
III O
J
W
ca
z z
III -III=
TRENCHING AND TRENCH REPAIR
IN ACCORDANCE WITH THE CITY
OF FONTANA STD. PLAN 1008.
VICINITY MAP
NOT TO SCALE
«<
CONSTRUCTION NOTES QUANTITIES
O INSTALL 24" RCP STORM DRAIN (D -LOAD PER PROFILE) 442 LF
O2 CONSTRUCT MANHOLE PER CITY OF FONTANA STD. PLAN 3013. 1 EA
O CONSTRUCT MODIFIED MANHOLE PER CITY OF FONTANA STD. PLAN 3011. AND PROFILE 1 EA
O REMOVE PIPE CLOSURE AND CONNECT STREET DRAIN 1 EA
*1♦WOUlce J�l��♦��D11119W.AlWW4411111
GAS:
CABLE:
- 6' MIN. ,
TIME WARNER CABLE
N
z III 8" MAX.
FONTANA, CA 92335
ONTARIO, CA. 91761
PHONE: 909.428.8411
Lu
ELECTRIC:
SEWER:
z
CITY OF FONTANA
7951 REDWOOD AVE.
O
FONTANA, CA. 92336
FONTANA, CA 92335
N
PHONE: 909.350.6632
w
ENGINEER:
LEGEND
NORTH FONTANA INVESTMENT CO., LLC
MADOLE AND ASSOCIATES, INC.
a
o
G.B.
o
O
STORM DRAIN PIPE
BEDDING MATERIAL SHALL MEET OR EXCEED SECTION
306-1.2.1, STD. SPECS FOR PUBLIC WORKS
CONSTRUCTION, LATEST EDITION. LOCALLY EXCAVATED
NATIVE MATERIALS MAY BE BLENDED TO THE REQUIRED
SAND EQUIVALENCY OF 30 OR GREATER
=III
6"MIN. III =
8" MAX. = I I I
III=
III m
III O
J
W
ca
z z
III -III=
TRENCHING AND TRENCH REPAIR
IN ACCORDANCE WITH THE CITY
OF FONTANA STD. PLAN 1008.
VICINITY MAP
NOT TO SCALE
«<
CONSTRUCTION NOTES QUANTITIES
O INSTALL 24" RCP STORM DRAIN (D -LOAD PER PROFILE) 442 LF
O2 CONSTRUCT MANHOLE PER CITY OF FONTANA STD. PLAN 3013. 1 EA
O CONSTRUCT MODIFIED MANHOLE PER CITY OF FONTANA STD. PLAN 3011. AND PROFILE 1 EA
O REMOVE PIPE CLOSURE AND CONNECT STREET DRAIN 1 EA
*1♦WOUlce J�l��♦��D11119W.AlWW4411111
GAS:
CABLE:
SOUTHERN CALIFORNIA GAS COMPANY
TIME WARNER CABLE
16231 VALLEY BLVD.
1205 DUPONT AVENUE
FONTANA, CA 92335
ONTARIO, CA. 91761
PHONE: 909.428.8411
PHONE: 909.390.4738
ELECTRIC:
SEWER:
SOUTHERN CALIFORNIA EDISON COMPANY
CITY OF FONTANA
7951 REDWOOD AVE.
8353 SIERRA AVENUE
FONTANA, CA. 92336
FONTANA, CA 92335
PHONE: 909.357.6221
PHONE: 909.350.6632
WATER:
WEST VALLEY WATER DISTRICT
855 W. BASELINE ROAD
RIALTO, CA 92377
PHONE: 909.875.1361
TELEPHONE:
AT&T
11464 TELEGRAPH ROAD SANTA
FE SPRINGS, CA 90670
PHONE: 714.666.5415
SHEET INDEX
TITLE 1
GARDENS STREET STORM DRAIN 2
cn
z
z
Q
0
0
F-
cn
Q
c�
w
Q
w
w
F-
z
w
0
Of
Q
CD
ci
�r-
N
I
co
N
z
D
J:\126-2348\storm\Y Street Lat\SD Ol.dwg, 4/24/2017 7:49:51 AM, DWG To PDF.pc3
RCP TRENCH DETAIL
NOT TO SCALE
OWNER/DEVELOPER
ENGINEER:
LEGEND
NORTH FONTANA INVESTMENT CO., LLC
MADOLE AND ASSOCIATES, INC.
A.C.
ASPHALTIC CONCRETE
G.B.
GRADE BREAK
W
WIDTH
1156 N. MOUNTAIN AVE.
9302 PITTSBURGH AVE., SUITE 230 RANCHO
B.C.
BEGIN CURVE
H.P.
HIGH POINT
V
VERTICAL DEPTH
UPLAND, CA 91786-0670
CUCAMONGA, CA 91730 PHONE:
B.V.C.
BEG. VERTICAL CURVE
INV.
INVERT
(590.69)
EXISTING ELEVATION
PHONE: 909.985.0971
909.481.6322 FAX: 909.481.6320
B.W.
BACK SIDEWALK
O.C.
ON CURVE
590.69
PROPOSED ELEVATION
CONTACT: STACEY SASSAMAN
CONTACT: MARK BERTONE
C.B.
C.L.
CATCH BASIN
CENTERLINE
P.C.C.
PORTLAND CEMENT CONCRETE
[590.69]
FUTURE ELEVATION
D/L
DAY LIGHT
SMH
SEWER MANHOLE
_ _
_ Y_
_
_ SLOPE 2:1
E.C.
END CURVE
T, FTG.
TOP OF FOOTING
D
AC PAVEMENT
E.P.
EDGE PAVEMENT
THDW
TOP OF HEADWALL
E.G.
EDGE GRADE
(R)
RIDGE LINE
REMOVAL
E.V.C.
END VERTICAL CURVE
R/W
RIGHT OF WAY
GRIND
F.L.
FLOW LINE
TAN.
TANGENT
F.S.
FINISH SURFACE
T.C.
TOP OF CURB
EDGE OF PAVEMENT
SHEET INDEX
TITLE 1
GARDENS STREET STORM DRAIN 2
cn
z
z
Q
0
0
F-
cn
Q
c�
w
Q
w
w
F-
z
w
0
Of
Q
CD
ci
�r-
N
I
co
N
z
D
J:\126-2348\storm\Y Street Lat\SD Ol.dwg, 4/24/2017 7:49:51 AM, DWG To PDF.pc3