HomeMy WebLinkAbout5518-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT
PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL
REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED
BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY
REPORT SAID CONFLICT TO THE CITY ENIGNEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE
REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN
THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED
IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE
DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER
TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET
OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY
SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE
DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL
ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE
PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL
BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION
OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE
CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE
EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED
TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE
GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE
AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE
OPERATION AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO
CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS
WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES
AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE
CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS
CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM
12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND
EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE
WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER
HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO
PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR
WRITTEN APPROVAL.
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND APPROXIMATE LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS
WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING
UTILITIES OR STRUCTURES EXCEPT AS SHOWN ON THESE PLANS. THE ENGINEER NEITHER ASSUMES ANY LIABILITY AS TO
THE EXACT LOCATION OF SAID LINES NOR FOR UTILITIES OR IRRIGATION LINES WHOSE LOCATIONS ARE NOT SHOWN. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL UTILITY AND IRRIGATION COMPANIES PRIOR TO WORK ON
EXCAVATION TO DETERMINE EXACT LOCATION OF ALL LINES AFFECTING THIS WORK, WHETHER OR NOT SHOWN HERON, AND
FOR ANY DAMAGE OR PROTECTION OF THESE LINES.
CITY OF FONTANA
STREET IMPROVEMENT PLANS
DUNCAN CANYON ROAD - PHASE 2
GENERAL NOTES CONT.
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED
DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS
OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE
SWALES ENTERING OR LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF
CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING
CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER
LATERAL.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED
AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY
ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS
SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR
APPROVAL UPON COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE
PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34, UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND
OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE
CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL
PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
L
L
------- ---------------
I
I`
----------------
INDEX MAP
SCALE -.l"=200'
WILY S'LY
R/W R/W
I FUTURE IMPROVEMENTS
CONSTRUCTION NOTES
0 CONSTRUCT 6.5"(MIN.) AC PAVEMENT OVER 12" NATIVE MATERIAL
COMPACTED TO 95% PER CITY STD. PLAN NO. 401.
O2 CONSTRUCT 8" CURB FACE P.C.C. CURB & GUTTER PER CITY STD. PLAN NO. 1000.
O3 CONSTRUCT 4" P.C.C. SIDEWALK PER CITY STD PLAN NO. 1006 (W=6').
O CONSTRUCT BARRICADE PER CITY STD. PLAN NO. 4000.
O CONSTRUCT 10' WIDE CROSS GUTTER PER CITY STD. PLAN NO. PLAN 403.
O CONSTRUCT CURB RETURN ACCESS RAMP PER CITY STD. PLAN NO. 1003.
O CONSTRUCT 8" TO 6" CURB FACE P.C.C. CURB TRANSITION.
O INSTALL DECORATIVE LED STREET LIGHT - SCE # 10184043 (165 WATTS) PER
CITY STD. PLAN NO. 404, CASE 1; CARPINTERIA POLE AND TEARDROP FIXTURE.
O ADJUST MANHOLE TO GRADE PER CITY STD. PLAN NO. 2000.
10 CONSTRUCT 4"(MIN.) AC PAVEMENT OVER 12" NATIVE MATERIAL
COMPACTED TO 95% PER CITY STD. PLAN NO. 400.
11 REMOVE EXISTING BARRICADE.
12 PAVE AROUND MANHOLE RIM AND COVER.
13 CONSTRUCT ENHANCED CURB RETURN ACCESS RAMP PER CITY STD. PLAN NO. 1003.
AND DETAIL ON THIS SHEET.
14 INSTALL FIRE HYDRANT MARKER PER CITY STD. PLAN NO. 6001.
15 ADJUST WATER VALVE TO GRADE.
THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT (U.S.A.), PHONE NUMBER 1-800-227-2600 TWO WORKING
DESCRIPTION
1
STREET IMPROVEMENT TITLE SHEET
2-3
DUNCAN CANYON ROAD PLAN AND PROFILE
R/W
RIGHT OF WAY
DAYS BEFORE DIGGING. NO CONSTRUCTION PERMIT, ISSUED BY THE PUBLIC WORKS DEPARTMENT, SHALL BE VALID
BEG. VERTICAL CURVE
TAN.
108'
B.W.
BACK SIDEWALK
T.C.
TOP OF CURB
INVOLVING UNDERGROUND FACILITIES, UNLESS THE APPLICANT HAS AN INQUIRY IDENTIFICATION NUMBER ISSUED BY THE
LANDSCAPE LOT
W
WIDTH
C.L.
CENTERLINE
V
U.S.A.
AT ARBORETUM S.P.
1 0'
12'
42' CL
E.P.
42'
13'
12'
10'
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS
590.69
INDICATES PROPOSED ELEVATION
8
6 8
20 13 9'_
INDICATES FUTURE ELEVATION
9
13 20
y y
8 6
,
8
FINISH SURFACE
DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
PROP. AC
PAVEMENT
G.B.
GRADE BREAK
D
AC PAVEMENT
H.P.
HIGH POINT
REMOVAL
INV.
INVERT
O.C.
ON CURVE
®
GRIND
P.C.C.
THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL
2:1 MAX.
2% MIN.
EDGE OF PAVEMENT
COMPANY 11464 TELEGRAPH ROAD
COMPANY
2% MIN.
16231 VALLEY BLVD. SANTA FE SPRINGS, CA 90670
30'
FONTANA, CA 92335 PHONE: 714.666.5415
DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR
_-::C2:1 MAX.
FUTURE
PHONE: 909.428.8411
EXIST.
MED. CURB
ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM
2:1 MAX. --\",
27. _ _ _GROUND _ 2:1
MAX
_
2%
THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
7
_ - _
,
6
� CONC.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER
FUT. SIDEWALK
FUT. AC J
PAVEMENT FUTURE
PROP. AC
SIDEWALK
PRIOR TO THE COMMENCEMENT OF ANY WORK. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER
MED. CUPT
PAVEMENT
3
O
OF ANY DISCREPANCIES. BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS. CONTRACTOR
FUT. CURB 1' DEEP
& GUTTER
DIRT
CONC. CURB
SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS.
SWALE
SHOULDERO
& GUTTER
0
CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER VALVE BOXES, UTILITY BOXES AND LIDS, ETC.
TYPICAL
SECTION
THE ENGINEER PREPARING THESE PLANS SHALL NOT BE HELD RESPONSIBLE OR LIABLE FOR UNAUTHORIZED CHANGES TO
DUNCAN CANYON
ROAD
ORE SES OF THESE PLANS. ALL CHANGES TO THESE PLANS SHALL BE REQUESTED IN WRITING AND MUST BE APPROVED BY
ENG
T.I. =
10.0
QUANTITIES SHOWN HEREON ARE PROVIDED FOR PERMIT AND BONDING PURPOSES ONLY. CONTRACTOR SHALL BE
RESPONSIBLE FOR DETERMINING THEIR OWN QUANTITIES PRIOR TO BIDDING AND CONSTRUCTION. THE ENGINEER IS NOT
RESPONSIBLE FOR DISCREPANCIES IN FINAL CONSTRUCTION QUANTITIES.
0
0
N
I I
w
Q
U
cn
6" WIDE NATI
CONCRETE
NATURAL CO
3/16
PAVING DEPTH REBAR
PER CITY STANDARD
.DEC
M
NO SCALE
PROVIDE 24" SQUARE
SAW -CUT GRID PER
DETAIL BELOW
13 ENHANCED HC RAMP DETAIL
SCALE :1' - 20'
QUANTITIES
30,200 S.F.
1,227 TONS
935 L.F.
6,600 S.F.
150 L.F.
1,278 S.F.
3 EA.
110 L.F.
2 EA.
1 EA.
1,230 S.F.
31 TONS
35 L.F.
32 S.F.
1 EA.
1 EA.
1 EA.
VICINITY MAP
NOT TO SCALE
SHEET INDEX
SHEET NO.
DESCRIPTION
1
STREET IMPROVEMENT TITLE SHEET
2-3
DUNCAN CANYON ROAD PLAN AND PROFILE
R/W
RIGHT OF WAY
lR*f_ :Q j
A.C.
ASPHALTIC CONCRETE
(R)
RIDGE LINE
B.C.
BEGIN CURVE
R/W
RIGHT OF WAY
B.V.C.
BEG. VERTICAL CURVE
TAN.
TANGENT
B.W.
BACK SIDEWALK
T.C.
TOP OF CURB
C.B.
CATCH BASIN
W
WIDTH
C.L.
CENTERLINE
V
VERTICAL DEPTH
E.C.
END CURVE
(590.69)
INDICATES EXISTING ELEVATION
E.P.
EDGE PAVEMENT
13'
E.G.
EDGE GRADE
590.69
INDICATES PROPOSED ELEVATION
E.V.C.
END VERTICAL CURVE
[590.69]
INDICATES FUTURE ELEVATION
F.L.
FLOW LINE
y y
INDICATES SLOPE 2:1
F.S.
FINISH SURFACE
PROP. AC
PAVEMENT
G.B.
GRADE BREAK
D
AC PAVEMENT
H.P.
HIGH POINT
REMOVAL
INV.
INVERT
O.C.
ON CURVE
®
GRIND
P.C.C.
PORTLAND CEMENT CONCRETE
1 % -
EDGE OF PAVEMENT
1z PAVING AROUND MANHOLE RIM +COVER
NTS
a -
Lo >_
LIST
FUTURE
LLLL
SEWER: CABLE:
WATER -
LLLLLL
LLLLLL
LLLLLL
LLLLL
MANHOLE
WEST VALLEY WATER DISTRICT
(TYP)
COVER
1
1z PAVING AROUND MANHOLE RIM +COVER
NTS
DUNCAN CANYON ROAD
TYPICAL SECTION (N.T.S.)
AT MEDIAN LEFT TURN LANE
ENGINEER:
MADOLE AND ASSOCIATES, INC.
CONSULTING a& E"EE IS AND
LAND PLANNERS
9302 PITTSBURGH AVE., SUITE 230
RANCHO CUCAMONGA, CA 91730
PHONE: 909.481.6322
CONTACT. MARK BERTONE
OWNER/DEVELOPER
NORTH FONTANA INVESTMENT CO., LLC
1156 N. MOUNTAIN AVE.
UPLAND, CA 91786-0670
PHONE: 909.985.0971
CONTACT- STACEY SASSAMAN
i
CITY OF FONTANA UTILITY NOTIFICATION
LIST
FUTURE
SEWER: CABLE:
WATER -
CITY OF FONTANA TIME WARNER CABLE
WEST VALLEY WATER DISTRICT
30'
CL
8353 SIERRA AVENUE 1205 DUPONT AVENUE
855 W. BASELINE ROAD
LANDSCAPE
13'
VARIES
FONTANA, CA 92335 ONTARIO, CA. 91761
RIALTO, CA 92377
LOT
4 -12'.
PHONE: 909.350.6632 PHONE: 909.390.4738
PHONE: 909.875.1361
PROP. AC
PAVEMENT
p' -g'
FU T. AC
PAVEMENT
GAS- TELEPHONE:
ELECTRIC
?%
SOUTHERN CALIFORNIA GAS AT&T
SOUTHERN CALIFORNIA EDISON
2:1 MAX.
� 2%
1 % -
COMPANY 11464 TELEGRAPH ROAD
COMPANY
2% MIN.
16231 VALLEY BLVD. SANTA FE SPRINGS, CA 90670
7951 REDWOOD AVE.
FONTANA, CA 92335 PHONE: 714.666.5415
FONTANA, CA. 92336
_-::C2:1 MAX.
FUTURE
PHONE: 909.428.8411
PHONE: 909.357.6221
MED. CURB
DUNCAN CANYON ROAD
TYPICAL SECTION (N.T.S.)
AT MEDIAN LEFT TURN LANE
ENGINEER:
MADOLE AND ASSOCIATES, INC.
CONSULTING a& E"EE IS AND
LAND PLANNERS
9302 PITTSBURGH AVE., SUITE 230
RANCHO CUCAMONGA, CA 91730
PHONE: 909.481.6322
CONTACT. MARK BERTONE
OWNER/DEVELOPER
NORTH FONTANA INVESTMENT CO., LLC
1156 N. MOUNTAIN AVE.
UPLAND, CA 91786-0670
PHONE: 909.985.0971
CONTACT- STACEY SASSAMAN
i