HomeMy WebLinkAbout5604-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE
CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN
BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS
OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL
IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER
TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5
FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY
SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF
THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET
SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE
THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO
WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY
COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE
AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR
VALVE OPERATION AND WATER REQUIREMENTS.
13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS
WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT
TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED.
THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO
MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES.
19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED
ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT
PRIOR WRITTEN APPROVAL.
20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED
DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS
OBTAINED.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING
CONCRETE.
24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL
CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWN STREAM MANHOLE, SEE
CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY
PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION
C700 FOR V.C.P..
26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY
ENGINEER.
27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR
MINOR DEFLECTIONS IN ALIGNMENT.
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION
AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT
IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY
THE CITY ENGINEER.
30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND
SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT-OF-WAY, THE LATERAL
SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER
LATERAL.
32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT.
36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY
THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES,
AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL
PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
CITY OF FONTANA
IN -TRACT SEWER IMPROVEMENT PLANS
TRACT NO.199601 lfw`60-11lfm`60-2119960-3
PRIVATE ENGINEER S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE
PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE
ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO
TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE
CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB
SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL
PERSONS AND PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE
ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE
PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO
THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO NOTIFY THE ENGINEER OF ANY DISCREPANCIES. BEGINNING OF WORK MEANS
ACCEPTANCE OF CONDITIONS.
CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS.
CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER VALVE BOXES, UTILITY BOXES
AND LIDS, ETC.
CONTRACTOR SHALL PROVIDE ALL THE NECESSARY PIPE FITTINGS TO COMPLETE THE WORK.
THE ENGINEER PREPARING THESE PLANS SHALL NOT BE HELD RESPONSIBLE OR LIABLE FOR UNAUTHORIZED
CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THESE PLANS MUST BE REQUESTED IN WRITING
AND MUST BE APPROVED BY THE ENGINEER OF RECORD.
QUANTITIES SHOWN HEREON ARE PROVIDED FOR PERMIT AND BONDING PURPOSES ONLY. CONTRACTOR
SHALL BE RESPONSIBLE FOR DETERMINING THEIR OWN QUANTITIES PRIOR TO BIDDING AND CONSTRUCTION.
THE ENGINEER IS NOT RESPONSIBLE FOR DISCREPANCIES IN FINAL CONSTRUCTION QUANTITIES.
PL
RIW - , I PROP. 4' SIDEWALK
CURB LINE
WATER MAIN
W -
0
SEWER MAIN N
PL
T MIN.
T MIN.
5' MIN.
5' MIN.
F
EWER LATERAL
\TER SERVICE METER
TYPICAL SEWER LATERAL AND WATER SERVICE DETAIL
NOT TO SCALE
NOTES:
1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE
ZONE.
2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE
ADEQUATE SHORING.
3. CLASS II AGG. BASE ALL TRENCHES LESS THAN 100' IN
LENGTH.
4. COMPACTION SHALL BE 90% IN ALL ZONES UNLESS
OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM
TO CAL -OSHA REQUIREMENTS.
5. THE SEWER PLUMBER TO VERIFY THE ULTIMATE BACKFLOW
PREVENTION VALVE.
TOP OF STRUCTURAL
PAVEMENT SUBGRADE
6" MIN.
10" MAX.
6" MAX. SIZE -
NATIVE SOIL
COMPACTED 90%
8" V.C.P. -
BEDDING MATERIAL SHALL MEET OR EXCEED SECTION
306-1.2.1, STD. SPECS FOR PUBLIC WORKS
CONSTRUCTION, LATEST EDITION. LOCALLY EXCAVATED
NATIVE MATERIALS MAY BE BLENDED TO THE REQUIRED
SAND EQUIVALENCY OF 30 OR GREATER
CITY OF FONTANA UTILITY NOTIFICATION LIST
ELECTRIC
CABLE:
SOUTHERN CALIFORNIA EDISON COMPANY
TIME WARNER CABLE
7951 REDWOOD AVE.
1205 DUPONT AVENUE
FONTANA, CA. 92336
ONTARIO, CA. 91761
PHONE: 909.357.6221
PHONE: 909.390.4738
GAS-
TELEPHONE:
SOUTHERN CALIFORNIA GAS COMPANY
AT&T
16231 VALLEY BLVD.
11464 TELEGRAPH ROAD
FONTANA, CA 92335
SANTA FE SPRINGS, CA 90670
PHONE: 909.428.8411
PHONE: 714.666.5415
��
y
3" MAX. SIZE NATIVE
SOIL COMPACTED 95%
6" MIN.
10" MAX.
1:1 SLOPE OR FLATTER
OR ADEQUATE SHORING
1" MAX. SIZE SELECTED
NATIVE BEDDING
COMPACTED TO 90%
N Z
w o
�o
a o
TYP. BEDDING FOR 8" VCP
LESS THAN 10' DEEP
NTS
SEWER:
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92335
PHONE: 909.350.6632
WATER
WEST VALLEY WATER DISTRICT
855 W. BASELINE ROAD
RIALTO, CA 92377
PHONE: 909.875.1361
INDEX MAP
SCALE:1 "=200'
NORTH OR WEST
RIW
0.5' I i 5' 1 4.5'
PROP. WATER
7' 8' 18.5' PROP. SEWER
O
PROP. SD
TYPICAL UNDERGROUND UTILITY LOCATION
SCALE: 1"=10'
OWNER/DEVELOPER ENGINEER:
NORTH FONTANA INVESTMENT COMPANY, LLC MADOLE AND ASSOCIATES, INC.
1156 N. MOUNTAIN AVE. 9302 PITTSBURGH AVE., SUITE 230
UPLAND, CA 91786-0670 RANCHO CUCAMONGA, CA 91730
PHONE: 909.985.0971 PHONE: 909.481.6322
CONTACT: STACEY SASSAMAN FAX: 909.481.6320
CONTACT: MARK BERTONE
0
0
N
w
J
Q
U
co
SOUTH OR EAST
RIW
4.5' 1 5' 11 0.5'
VICINITY MAP
NOT TO SCALE
LEGEND
w
J
Q
U
U)
0
0
Z
1No
AC
60'
RIW
RIGHT OF WAY
CL
BC
20'
_I_
TANGENT
20'
PROP. WATER
7' 8' 18.5' PROP. SEWER
O
PROP. SD
TYPICAL UNDERGROUND UTILITY LOCATION
SCALE: 1"=10'
OWNER/DEVELOPER ENGINEER:
NORTH FONTANA INVESTMENT COMPANY, LLC MADOLE AND ASSOCIATES, INC.
1156 N. MOUNTAIN AVE. 9302 PITTSBURGH AVE., SUITE 230
UPLAND, CA 91786-0670 RANCHO CUCAMONGA, CA 91730
PHONE: 909.985.0971 PHONE: 909.481.6322
CONTACT: STACEY SASSAMAN FAX: 909.481.6320
CONTACT: MARK BERTONE
0
0
N
w
J
Q
U
co
SOUTH OR EAST
RIW
4.5' 1 5' 11 0.5'
VICINITY MAP
NOT TO SCALE
LEGEND
w
J
Q
U
U)
0
0
Z
1No
AC
ASPHALTIC CONCRETE
RIW
RIGHT OF WAY
BC
BEGIN CURVE
TAN
TANGENT
BVC
BEG. VERTICAL CURVE
TC
TOP OF CURB
BW
BACK SIDEWALK
W
WIDTH
CB
CATCH BASIN
V
VERTICAL DEPTH
CL
CENTERLINE
(590.69)
INDICATES EXISTING ELEVATION
EC
END CURVE
590.96
INDICATES PROPOSED ELEVATION
EP
EDGE PAVEMENT
[590.691
INDICATES FUTURE ELEVATION
EG
EDGE GRADE
EVC
END VERTICAL CURVE
INDICATES SLOPE 2:1
FL
FLOW LINE
0
AC PAVEMENT
FS
FINISH SURFACE
GB
GRADE BREAK
0
REMOVAL
HP
HIGH POINT
0
GRIND
INV
INVERT
OC
ON CURVE
EDGE OF PAVEMENT
PL
PROPERTY LINE
PCC
PORTLAND CEMENT CONCRETE
(R)
RIDGE LINE
CONSTRUCTION NOTES
QUANTITIES
10 INSTALL 8" EXTRA STRENGTH V.C.P. SEWER - -
- - - - -
- - - - - - - - -
8,810 L. F.
O2 CONSTRUCT 48" PRECAST CONCRETE MANHOLE PER CITY OF FONTANA STD. DWG.
NO'S.2000,2001&2003_---------------------_
32 EA.
O3 INSTALL 4" V.C.P. SEWER LATERAL AND CLEANOUT BOX PER CITY OF FONTANA STD.
DWG. NO. 2005.-------------------------
7,960 L.F.
4T INSTALL BACKWATER VALVE DEVICE
139 EA
O INSTALL SEWER TERMINAL CLEANOUT PER CITY OF
FONTANA STD. DWG. NO. 2004.
2 EA
LAY WYESFLAT _-----------------------_
O
1 EA
VARIES
8" SEWER MAIN
?.00% (MIN.)
4" LATERAL
FLAT WYE DETAIL
SEE SHEET 7, LOT 34
NTS
wkllE
6
p�1(_89 Sp pR
12" MIN. CLEARANCE
(OR ENCASE IN CONCRETE)
J:\126-2659\sewer\TR 19960\Sew0l.dwg, 4/25/2017 2:13:02 PM, DWG To PDF.pc3