Loading...
HomeMy WebLinkAboutTract 16678HYDROLOGY/HYDRAULIC STUDY For DRAINAGE OFFSITE TRACT # 16678 FONTANA, CALIFORNIA Job No. 05086-000 September 10, 2004 Prepared for Pacific Grove Corporation 19 Corporate Plaza, Suite 210 Newport Beach, CA 92660 (949)706-6750 Prepared By Hall & Foreman, Inc. 9130 Anaheim Place, Suite 120 Rancho Cucamonga, CA 91730 (909) 484-9090 Herman Hovagimyan RCE# 20278, Exp. 9/30/05 Mr Half- & Foreman, Inc. T .j Civil Engineering - Planning - Surveying • Public Works ?,pFESSIpNgC otic W Herman S. Hovagimyan No.20278 * Exp. 9-30- 05 Civil !' jqedicsicW Se,= - 1961- 00 rr Table of Contents 1. Discussion 2. Hydrology * 3. 100 Year 4. Line "DZ -6" 5. Line "DZ -6" Revised 6. Line "DZ -7 7. Line "DZ -5" 8. Line "DZ -5" Revised 9. Declez Channel 10. Declez Channel Revised 11. Hydraulics 40 12. Declez Channel 13. Declez Channel Revised 14. Line "DZ -5" Revised w r1 DISCUSSION In PURPOSE 41 The purpose of this report is to verify that the proposed storm drain (per master plan) in Santa Ana Ave., west of Cypress Avenue and in Oleander Ave. will be sufficient to take ,0 the flow (Qioo) from Tract 16678 and offsite, after development of the tract is complete. as All drainage systems have been designed to carry a 100 -year frequency storm. SITE 49 This tract is located on the and northeast corner of the intersection of Cypress Avenue and Santa Ana Avenue in the city of Fontana, California (Vicinity Map, Figure 1). The tract comprises approximately 55 acres (gross) and is bounded to the north by vacant 41 land: to the south by Santa Ana Avenue, to the west by Cypress Avenue; and to the east by Juniper Avenue. The drainage area extends farther north and east as shown on the 100 year Hydrology (figure 7), which is part of "South Fontana Master Plan of Drainage Study, Empire Center Area" by Hall & Foreman, Inc., 2004. The highlighted area is tract 16678. The area numbers and note numbers are those of Hall & Foreman's above-mentioned study. a SITE OF TOPOGRAPHY The general site vicinity slopes downward to the southwest. The site is relatively flat. s Drainage from the site is via sheet flow to Cypress Avenue and Santa Ana Avenue. SUMMARY r Sections "DZ -5", "DZ -6", and "DZ -7" are plotted from Hall & Foreman's original study (as mentioned above) of the overall area prior to the tract development "DZ -5" revised and "DZ -6" revised calculations are both revised to reflect this study. The 84" pipe is Oleander Ave., north to Jurupa Ave to Santa Ana Ave., from the "Master Plan" should be increased to 90" to contain adequately all of the flow. However to 84" +� pipe west of Cypress Ave. from the "Master Plan" will adequately contain all of the flow with the minimum pipe slope of 0.0048. Then the detention basin on tract 16678 will no " longer be necessary. 0 d +w ar w ar do ws im 44 AN i i 40 do 44 dfi w e9 +m AN N 0 - FROM :HALL&FOREMAN,INC—TEMECULA FAX NO. :951-699-0996 Sep. 02 2004 09:46AM P1 HYDROLOGY wo FROM :HRLL&FOREMRN,INC—TEMECULR FAX NO. :951-699-0896 Sep. 02 2004 09:46AM P2 11 OM V4 V� AV �tjq&w Cr. t-, '0 UOL MW &AY AY PIKH10 'm ro St film mom K D OA v L MKOR a _1_ Y I It IT ST_ a PINE ..hv. 41M HIL&ALL ' " " 12 —1 1 .c E riz a ; g #I a I'll, 14L AINCOAL 4 : 17,'MI �t13.AY 2 RAND �LL i TF `%% AL L 119 AV UNALL 13 Aa -ma- SEIIII N loo ruLIP weLIP I! CL W'LUA Lx � ZT7 V FIL IJ AV 0 Lam In - FILB j AlynAV K z F I L1I MWIPW ji-AWTAM AV t HOLLY A UR ...OR r7 9 K IT IA SAN 4d LY F v 'SAN IEr " BEPXAR0140 AV ir, I r, I U - In IT I j :TULLD4 do 9L z L E CT SAM am Lua -Ft LD P '2 1.9 PIAJI rh yjrJl ININ OR TIM. - VAL I I y 124 BLVD VALLEY LVO !7.1�; SAN WAS)f JGTUN. sspi Lo SIP AV AV NOYLE r .......... .... YLE FON NA SLOVLI 40 3 A:11 SLOVf I AV Ng I FS 21 29 2y I•wxlNc pierT I r-__P 4LI AL 04 DR . . . . . . . . . . ... Irl _. r'6- G.- _�..i___ IDS 'T : .. _. .. ..- ��Ei � �/ -Ing Ism I;ZoJANA 25 .9 2 jER AN LWAL-AN LM co, U, AMPA JU PA_ isnaf_= 15000 told -rT7FFAWG p Ail Wr di c 4 AM 32 NA 41 %muff tOV I y Tl� 44T 44 T1 1� :'RSIDE VICINITY MAP FROM :..HALL&FOREMAN,INC-TEMECULA FAX N0. :951-699-0896 Sep. 02 2004 09:47AM P3 3 .� -!J. • Y" y:\ 'Itty '-�;7T.1'�-s'i i•C,' `;� 11q� 1t� �. i 1 y , / i• .ry - . do{ �a„1 � J "�,(� '(f`.•,jl �,' ri y���� �.: �y':��, !•7 ,e \�' .t:, •j. '��4 '�.• C,•� � � '��Jj ■. ![ `�°�Y '' '` w !�' .�,�,bi. ,,,` (�:r' 41::.1'�•v' r"•�.�.1..[ ;�d':• q'�•": k_"'t�:�a.,i `�..2::� �� .t ,, / :• .r� 1 P ,��n " •/,• j n `,. `F:1,',.jli. "',•.-4h.,f.�L�jar}'i: '..:ar�-••..•j4^OtfV.'„,r✓f...a.:'i:�•',"1\>,'4�''!Lf •''`. . • �.` .J. ..r', \.y ,. C��'x'L�� j, �i, [. ��d•yd,Y.,, , , !^,•, 'L )..�C':: ln77 r:�yj. �, - 419 LL Ly rg �� �. �, ..%• .A"r�'�P"v,�11,„� �, ,T,...,�';- �al.l:rl•�, •:rt:R �•+a.!*a �% .�.�r «, _�ti� . , r,. l � .�����. , �•... .lh.�"41:\". .. i'r,: .:. l601Mli 0f0��' ifA►� ',. ' ,A( ••,r'-: •.� ;ftl.';'[d•A .;A '�.'- ' ,� ,;;;�,' '��.:li-''��': `1.r1 Ji.. .�[+?IN1.9C�,� n• `l '. i � 1 f, '.�., f," • � _ r �.�`� ; ,.:r•',.i : '•'! � ( ..,-i. 1 Vii;!; Ti� >„i.: � - : i r ,f `i i - . _�. , r, . ,. - . �1 'r' �',.. .,nwy J r•1=i. • gym.- _ ”- .r: 7 4r , V ] ■ '� .% '.:: .:�'. �..- �-.,:`•:� ::.._� _ 'wi,.i;.� .. `.: 'TELA . �_. r ",. - -. -: -- 'i” .: .�: ,",,.,, ��I"' �.�;_,`:•,.. may" -_r" ' / I � rte''•-��� ,.. t, ';, ,rte` _ I I r� V ' • .� �{ _ - - � JIB � _ r ti: �•' �, 'I � •.,; u � � � '10' ,.i is ” ...... .«...... , .. . r .' ,: •� T 1 .m �`� /' '..;, C, 1i _.," .1. ' � '.1 �. �r• �(, ., .aV `�-1�.�I:�'I: "d'P,�•! I � �y�.►•• � - , tri 5��� r ' 1 "� -� ,'l� _ , ''!� J Y j. � sr: -�L' �.� -1 ,.'��, �°„,• .':• ; f .. 1 ,� ';'t � � , � �• �::f ' �Cr � `'I,1 _II j.I �- ;_ I-• — :'.::r. •r�. L•.,1 /!. ,rl ”. : \.)'��� I 1 ' • , � c' "' - - __ �''�. Gln . ; , :, i� �t . ,�•�� j ; , ., ., „ _;. . ... \ .-.A. s.��lq.7� �4dd' •a�.e.,r_Y_II�S .f -•'; '.r..1,6. , ti , �i ,r c r � ' - �- hi t i , it �,+''!p'" ��• ,`w �-c.�y- ! •.J .n. :':��•.;'�-.. :' A�+�� `•,!�i •- ' : -• ,ate L .. �... _.. .,•_ �,.%'4 t ,t'., � ; , 4.." � � ' � -•.� CwV ,,,. ' .. . �� .i ,' , I > �.�,'.':;,ii:�... r+ __ �. M'•1-��. ���'� Y..�''=—r,-_i �t ["•• .,:� 1 t... � tila' �ll:.Iil. 1v •I:• �t,�� r,. ,1�.a; ;i,•lwv.:J.lµw.1' MR JC a.V,�f SOILS GROUP MAP r►c, 2 FROM :HALL&FOREMAN,INC-TEMECULA FAX N0. :951-699-0896 Sep. 02 2004 09:48AM P4 Im go 0 .R ey 10 do H E E AN al .r ,. A •e so s ei 0 d .e id .0 is d SAN BERNARDINO COUNTY HYDROLOGY MANUAL D-4 r figure u -i Tc# LIMITATIONS, L 100 I. Maxlmum length = 1000 Feet To 1000 90 2. Maximum area = 10 Acres 5 -- (m IN 900. 80 n; e00 70 H s Y » i X00 0 700 60 a '� �! 300 > Q 200 3 7- n soo 50 0 100 N� 100 00 `e e E s _ all— 60 11 • v m d- 40 4 pg Q 500 V 20 9 .. 0r30 o m 6 10 400 K J- i c Undeveloped 0 Good Cover ' i 2 12 g � 330 25 Undeveloped 0 e I; 13 c Falr Cover v = 300 E 20 _ Undeveloped 4o 0 ,a �2 10 G ,S 19 Poor Cover , - 0 zo Z 16 c `c-; 18 Single Famlly 4k 17 E 250 � �6 (5-7 DWAC) 18 ~' r 15 Commercial QAC (Paved) 90 fig v % m 200 v �`, 14 13 u KEY_ L -H -TI: -K -Tc' 20 a a o �12�- `c II / 25 3 ° 10 PI Development u 150 9 80- Apartment o 1. 75- Mobile Home 30 8 65- Condominium 60- Single Family -5,000 its Lot 7 40- Single Family -1/4 Acre Lot 35 20- Single Family -I Acre Lot 6 10 - Single Family- 2 1/2 Acre Lot loo ao EXAMPLE 9 (1) La 550', H-5,0', K= Single Family (5-7 DU/AC) Development, Tc=12.6 min. (2 ) L= 550', H• 5.0', K2 Commercial 4 Development, Tc. g,7 min. SAN BERNARDINO COUNTY HYDROLOGY MANUAL D-4 r figure u -i FROM :HALL&FOREMRN,INC-TEMECULR FRX NO. :951-699-0896 Sep. 02 2004 09:4BRM P5 `LI T4N I' — —I.— R I I R6W I R I 4w I I �W I ;n r ° • I ; � � •ra IT � Wry 7 —e +. _ 1 _ 1 1 . , . , . • t I •• � .,, _ 1 .rt sox aiAt _ _ if r •i '':i •• q NOW UPLAND I. KIS/ Ll 77 - _ ... . FONTA dd TIS OMT 1 •I. T' N r t. +w �. ti i • o J. - llj • i �� -_j mm qM i t w .: : } I �....,• uaM to � '%y NINO ,ti. ""�• "',.,,fit.' .t _ , ,\ T23 i RSIDE • ,, ' R *� 1 - -" ' VALLEYAREA I I I n,Aon ' I. oo �arrnoi R5%' • T3S -- I •. Afiy � ; Io YR. IHR �' �•' ",.,, _..,'�. =� .�..�;.• A . I SAN, BERNARDINO r'.r � - I I••JieW I . R7W � '••.,, Iva --- HYDROLOGY MANUAL F I 6 3 i 1 IRA T7 INK I PAP MA / 4r ��' Alk■� �� �� liit� Is1�AEROT 1 LS Rio dr M`,*MAMM • P.. rL��1'�nAl�ip�� ' mow• �/���1� � �� �� .,� � � �1� _ t� FROM :HALL&FOREMAN,INC—TEMECULA +w w a vfW ■ im ld 41 ld w i aW FAX NO. :951-699-0896 Sep. 02 2004 09:51AM P10 >C Is' 30' a V44 OpI �4 - - B C — D SLOPE LEVEL UNE /e IA 2.0 % SEE NOTES ° SIDEWALK CURB & GUTTER TYPICAL SECTION ALTERNATE SIDEWALK LEVEL (IF SHOWN ON PLAN) A Ss s.5 LEVEL LINE I C TYPICAL SECTION TILT B" CURB LEVEL TILT 6° CURB LEVEL TILT A B C 0 0,00' 0.33' 0.2P' 0.33' 0.44' 0.66' 0.50' 033' 0,00 0.16' 0.05' 0.16' 0.44' 0.49' 0,33' 0.16' 1 NOTE I. STRUCTURAL SECTION OF ROADWAY SHALL BE DETERMINED FROM SOILS TESTS AND SO INDICATED ON CONSTRUCTION PLANS. 2. MINIMUM DESIGN PAVING THICKNESS SHALL It 0.20' ASPHALT CONCRETE, S. CONSTRUCTION OUTSIDE R/W WILL REQUIRE SLOPE EASEMENTS 4 WHEN PREPARING SUllGRADE FOR PAVIN¢, CENTERLINE CROWN ON THE 'LEVEL SECTION" SMALL BE RELOCATED EITH2R LEFT OR RIGHT 0.50 TO MATCH CROWN BREAK M PAVING MACHINE. SAN BERNARDINO COUNTY ROAD DEPARTMENT a►T[:IJ�9•G John R. Shone • LOCAL STREET 104 COUNTY HIOHWAY ENGINEER I@J W 1 „Q f-xchange Suite 10Q, - '� j� (n 78 JOB No. 0 50 (?G ,;IRE, CA -92602=140 301 ' ,va BY (e �iK! DATE , `665.=4500,_ SHT. - 99 mac. 4�:6f 5-4501 OF y: �. -Ad ♦ LAND PLANNING CIVIL ENGINEERING SURVEYING y 0 rrl 100 YEAR 0 419 40 48 .n go 4. lid 49 �r M L. Iloo San Bernardino County Rational Hydrology Program (Hydrology Manual Date - August 1986) �r CIVILCADD/CIVILDESIGN Engineering Software, (c) 1989-2001 Version 6.4 Rational Hydrology Study Date: 08/31/04 ------------------------------------------------------------------------ FONTANA / LINE DZ-6 HYDROLOGY 100 YEAR STORM JN 04339 ------------------------------------------------------------------------ Hall & Forman, Inc. - SIN 950 ------------------------------------------------------------------------ ********* Hydrology Study Control Information ********** ------------------------------------------------------------------------ Rational hydrology study storm event year is 100.0 10 Year storm 1 hour rainfall = 0.930(In.) 100 Year storm 1 hour rainfall = 1.350(In.) Computed rainfall intensity: Storm year = 100.00 1 hour rainfall = 1.350 (In.) Slope used for rainfall intensity curve b = 0.6000 Soil antecedent moisture condition (AMC) = 2 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 714.000 to Point/Station 715.000 **** INITIAL AREA EVALUATION **** COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1104.000(Ft.) Bottom (of initial area) elevation = 1092.000(Ft.) Difference in elevation = 12.000(Ft.) • Slope = 0.01200 s(%)= 1.20 TC = k(0.304)*[(length"3)/(elevation change)]-0.2 Initial area time of concentration = 11.669 min. Rainfall intensity = 3.606(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.876 M Subarea runoff = 22.101(CFS) Total initial stream area = 7.000(Ac.) " Pervious area fraction = 0.100 a� Initial area Fm value = 0.098(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 715.000 to Point/Station 716.000 �a **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** + Top of street segment elevation = 1092.000(Ft.) End of street segment elevation = 1089.000(Ft.) it Length of street segment = 800.000(Ft.) Height of curb above gutter flowline = 8.0(In.) 10 Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) a ■ �r ar Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side (s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.632(Ft.), Average velocity = Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: 39.465(CFS) 2.897(Ft/s) Halfstreet flow width = 20.000(Ft.) Flow velocity = 2.90(Ft/s) Travel time = 4.60 min. TC = 16.27 min. Adding area flow to street COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Rainfall intensity = 2.954(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.870 Subarea runoff = 24.165(CFS) for 11.000(Ac.) Total runoff = 46.266(CFS) Effective area this stream = 18.00(Ac.) Total Study Area (Main Stream No. 1) = 18.00(Ac.) •. Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 46.266(CFS) Half street flow at end of street = 23.133(CFS) Depth of flow = 0.666(Ft.), Average velocity = Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) 3.085(Ft/s) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 716.000 to Point/Station 717.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1089.000(Ft.) End of street segment elevation = 1081.500(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street Distance from curb to property line = 13.000(Ft.) 41 Slope from curb to property line (v/hz) = 0.020 M Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 'r Estimated mean flow rate at midpoint of street = 71.969(CFS) Depth of flow = 0.840(Ft.), Average velocity = 4.894(Ft/s) " Warning: depth of flow exceeds top of curb a Distance that curb overflow reaches into property = 8.67(Ft.) Streetflow hydraulics at midpoint of street travel: * Halfstreet flow width = 37.258(Ft.) Flow velocity = 4.89(Ft/s) Travel time = 2.25 min. TC = 18.52 min. Adding area flow to street COMMERCIAL subarea type ® Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Rainfall intensity = 2.733(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.868 Subarea runoff = 43.861(CFS) for 20.000(Ac.) Total runoff = 90.127(CFS) Effective area this stream = 38.00(Ac.) Total Study Area (Main Stream No. 1) = 38.00(Ac.) Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 90.127(CFS) Half street flow at end of street = 90.127(CFS) Depth of flow = 0.901(Ft.), Average velocity = 5.099(Ft/s) 'i Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 11.71(Ft.) Flow width (from curb towards crown) = 40.290 (Ft. ) A ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 717.000 to Point/Station 33.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1075.000(Ft.) Downstream point/station elevation = 1061.000(Ft.) Pipe length = 990.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 90.127(CFS) Given pipe size = 36.00(In.) NOTE: Normal flow is pressure flow in user selected pipe size. .. The approximate hydraulic grade line above the pipe invert is 7.857(Ft.) at the headworks or inlet of the pipe(s) Pipe friction loss = 18.070(Ft.) Minor friction loss = 3.787(Ft.) K -factor = 1.50 Pipe flow velocity = 12.75(Ft/s) �r Travel time through pipe = 1.29 min. Time of concentration (TC) = 19.81 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ,n Process from Point/Station 33.000 to Point/Station 33.000 **** CONFLUENCE OF MINOR STREAMS **** M Along Main Stream number: 1 in normal stream number 1 ZI M Stream flow area = Runoff from this stream Time of concentration = Rainfall intensity = Area averaged loss rate Area averaged Pervious 38.000(Ac.) = 90.127(CFS) 19.81 min. 2.625(In/Hr) (Fm) = 0.0978(In/Hr) ratio (Ap) = 0.1000 W ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 718.000 to Point/Station 719.000 4A **** INITIAL AREA EVALUATION **** COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 di SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1082.000(Ft.) 40 Bottom (of initial area) elevation = 1075.000(Ft.) Difference in elevation = 7.000(Ft.) Slope = 0.00700 s(%)= 0.70 TC = k(0.304)*[(length"3)/(elevation change)1^0.2 Initial area time of concentration = 12.997 min. Rainfall intensity = 3.380(In/Hr) for a 100.0 Effective runoff coefficient used for area (Q=KCIA) . Subarea runoff = 14.770(CFS) Total initial stream area = 5.000(Ac.) 'o Pervious area fraction = 0.100 Initial area Fm value = 0.098(In/Hr) ,. 0.098(In/Hr) year storm is C = 0.874 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 719.000 to Point/Station 720.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1075.000(Ft.) End of street segment elevation = 1073.300(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side (s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.561(Ft.), Average velocity = Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) 22.155(CFS) 2.057(Ft/s) ;,�),5 w Flow velocity = 2.06(Ft/s) Travel time = 5.35 min. TC = 18.34 min. M Adding area flow to street Ai COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 + Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Rainfall intensity = 2.749(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.868 Subarea runoff = 9.088(CFS) for 5.000(Ac.) Total runoff = 23.858(CFS) Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 48.00(Ac.) �r Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 23.858(CFS) Half street flow at end of street = 11.929(CFS) A Depth of flow = 0.573(Ft.), Average velocity = 2.119 (Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown) = 20.000(Ft.) d ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 720.000 to Point/Station 721.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1073.300(Ft.) End of street segment elevation = 1070.000(Ft.) ' Length of street segment = 330.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 ,. Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.530(Ft.), Average velocity = Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) ' Flow velocity = 3.75(Ft/s) Travel time = 1.47 min. TC = 19.81 min. Adding area flow to street " COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 „ Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 35.787(CFS) 3.746 (Ft/s) 0.098(In/Hr) Rainfall intensity = 2.625(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.866 Subarea runoff = 21.625(CFS) for 10.000(Ac.) °9 Total runoff = 45.483(CFS) Effective area this stream = 20.00(Ac.) Total Study Area (Main Stream No. 1) = 58.00(Ac.) Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 45.483(CFS) Half street flow at end of street = 22.742(CFS) Depth of flow = 0.567(Ft.), Average velocity = 4.120(Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 721.000 to Point/Station 722.000 ,rr **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** .! Top of street segment elevation = 1070.000(Ft.) End of street segment elevation = 1068.000(Ft.) Length of street segment = 330.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) ++� Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on (1] side (s) of the street Distance from curb to property line = 13.000(Ft.) .. Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500 (In. ) ,. Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 a Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 56.854(CFS) Depth of flow = 0.861(Ft.), Average velocity = 3.624(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 9.72(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 38.304(Ft.) a Flow velocity = 3.62(Ft/s) Travel time = 1.52 min. TC = 21.33 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 s Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342(In/Hr) Rainfall intensity = 2.511(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.836 Subarea runoff = 17.472(CFS) for 10.000(Ac.) Total runoff = 62.955(CFS) Effective area this stream = 30.00(Ac.) Total Study Area (Main Stream No. 1) = 68.00(Ac.) Area averaged Fm value = 0.179(In/Hr) Street flow at end of street = 62.955(CFS) Half street flow at end of street = 62.955(CFS) Depth of flow = 0.889(Ft.), Average velocity = 3.693(Ft/s) Warning: depth of flow exceeds top of curb 40 Distance that curb overflow reaches into property = 11.10(Ft.) Flow width (from curb towards crown)= 39.681(Ft.) +s 4d IN As ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 722.000 to Point/Station 722.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 30.000(Ac.) Runoff from this stream = 62.955(CFS) Time of concentration = 21.33 min. Rainfall intensity = 2.511(In/Hr) Area averaged loss rate (Fm) = 0.1793(In/Hr) Area averaged Pervious ratio (Ap) = 0.1833 Summary of stream data: ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 33.000 to Point/Station 34.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1061.00a(Ft.) Downstream point/station elevation = 1048.200(Ft.) Pipe length = 990.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 151.455(CFS) Given pipe size = 39.00(In.) Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) 1 90.127 19.81 2.625 2 62.955 21.33 2.511 Qmax (i ) _ 1.000 * 1.000 * 90.127) + 1.049 * 0.929 * 62.955) + = 151.455 w Qmax (2 ) _ 0.955 * 1.000 * 90.127) + 1.000 * 1.000 * 62.955) + = 149.029 ' Total of 2 streams to confluence: a Flow rates before confluence point: 90.127 62.955 ,* Maximum flow rates at confluence using above data: 151.455 149.029 Area of streams before confluence: 38.000 30.000 Effective area values after confluence: 65.867 68.000 Results of confluence: Total flow rate = 151.455(CFS) Time of concentration = 19.813 min. Effective stream area after confluence = 65.867(Ac.) Stream Area average Pervious fraction(Ap) = 0.137 Stream Area average soil loss rate(Fm) = 0.134(In/Hr) Study area (this main stream) = 68.00(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 33.000 to Point/Station 34.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1061.00a(Ft.) Downstream point/station elevation = 1048.200(Ft.) Pipe length = 990.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 151.455(CFS) Given pipe size = 39.00(In.) l08 ar NOTE: Normal flow is pressure flow in user selected pipe size. The approximate hydraulic grade line above the pipe invert is qm 28.262(Ft.) at the headworks or inlet of the pipe(s) 49 Pipe friction loss = 33.299(Ft.) Minor friction loss = 7.764(Ft.) K -factor = 1.50 Pipe flow velocity = 18.26(Ft/s) Travel time through pipe = 0.90 min. Time of concentration (TC) = 20.72 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 34.000 to Point/Station 34.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 65.867(Ac.) Runoff from this stream = 151.455(CFS) rr Time of concentration = 20.72 min. Rainfall intensity = 2.555(In/Hr) Area averaged loss rate (Fm) = 0.1337(In/Hr) Area averaged Pervious ratio (Ap) = 0.1368 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 723.000 to Point/Station 724.000 **** INITIAL AREA EVALUATION **** CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 . Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342(In/Hr) Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1072.000(Ft.) Bottom (of initial area) elevation = 1066.600(Ft.) Difference in elevation = 5.400(Ft.) Slope = 0.00540 s(%)= 0.54 TC = k(0.360)*[(1ength"3)/(elevation change)]^0.2 Initial area time of concentration = 16.212 min. Rainfall intensity = 2.960(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.796 a Subarea runoff = 11.781(CFS) Total initial stream area = 5.000(Ac.) . Pervious area fraction = 0.350 �r Initial area Fm value = 0.342(In/Hr) I. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 724.000 to Point/Station 725.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1066.600(Ft.) End of street segment elevation = 1063.000(Ft.) ,. Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) 44 am to �I11 Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.474(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 18.973(Ft.) Flow velocity = 2.41(Ft/s) Travel time = 4.57 min. TC = 20.78 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 17.672(CFS) 2.407(Ft/s) Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342(In/Hr) Rainfall intensity = 2.550(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified '* rational method)(Q=KCIA) is C = 0.779 Subarea runoff = 8.093(CFS) for 5.000(Ac.) Total runoff = 19.874(CFS) Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 78.00(Ac.) Area averaged Fm value = 0.342(In/Hr) Street flow at end of street = 19.874(CFS) " Half street flow at end of street = 9.937(CFS) Depth of flow = 0.492(Ft.), Average velocity = 2.478(Ft/s) Flow width (from curb towards crown)= 19.847(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 725.000 to Point/Station 729.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** r Top of street segment elevation = 1063.000(Ft.) * End of street segment elevation = 1056.600(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.558(Ft.), Average velocity = 19.874(CFS) 3.653(Ft/s) W AW Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 23.171(Ft.) Flow velocity = 3.65(Ft/s) Travel time = 3.01 min. TC = 23.79 min. Adding area flow to street COMMERCIAL subarea type Decimal fraction soil group A = 1.000 +� Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Rainfall intensity = 2.352(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.769 Subarea runoff = 0.000(CFS) for 0.000(Ac.) Total runoff = 19.874(CFS) �r Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 78.00(Ac.) • Area averaged Fm value = 0.342(In/Hr) a Street flow at end of street = 19.874(CFS) Half street flow at end of street = 19.874(CFS) Depth of flow = 0.558(Ft.), Average velocity = 3.653(Ft/s) Flow width (from curb towards crown)= 23.171(Ft.) "++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 729.000 to Point/Station 729.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 10.000(Ac.) Runoff from this stream = 19.874(CFS) Time of concentration = 23.79 min. Rainfall intensity = 2.352(In/Hr) Area averaged loss rate (Fm) = 0.3422(In/Hr) Area averaged Pervious ratio (Ap) = 0.3500 a ,R a a� 49 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 726.000 to Point/Station 727.000 **** INITIAL AREA EVALUATION **** CONDOMINIUM subarea type Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1069.200(Ft.) Bottom (of initial area) elevation = 1062.000(Ft.) Difference in elevation = 7.200(Ft.) Slope = 0.00720 s(g)= 0.72 TC = k(0.360)*[(length-3)/(elevation change)] -0.2 Initial area time of concentration = 15.305 min. Rainfall intensity = 3.064(In/Hr) for a 100.0 Effective runoff coefficient used for area (Q=KCIA) 0.257(In/Hr) year storm is C = 0.825 Subarea runoff Total initial �. Pervious area Initial area F 12.633(CFS) stream area = 5.000(Ac.) fraction = 0.350 m value = 0.257(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ■ Process from Point/Station 727.000 to Point/Station 728.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1062.000(Ft.) End of street segment elevation = 1060.000(Ft.) Length of street segment = 330.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) ar sr 48 Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on (2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.477(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 19.098(Ft.) Flow velocity = 2.55(Ft/s) Travel time = 2.16 min. TC = 17.46 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 18.950(CFS) 2.548(Ft/s) Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.257(In/Hr) Rainfall intensity = 2.831(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.818 Subarea runoff = 10.534(CFS) for 5.000(Ac.) s Total runoff = 23.167(CFS) Effective area this stream = 10.00(Ac.) * Total Study Area (Main Stream No. 1) = 88.00(Ac.) Area averaged Fm value = 0.257(In/Hr) Street flow at end of street = 23.167(CFS) Half street flow at end of street = 11.584(CFS) Depth of flow = 0.505(Ft.), Average velocity = 2.710(Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) n ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ „ Process from Point/Station 728.000 to Point/Station 729.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1060.000(Ft.) r e End of street segment elevation = 1056.600(Ft.) Length of street segment = 660.000(Ft.) r Height of curb above gutter flowline = 8.0(In.) At Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2) side (s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.578(Ft.), Average velocity = Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 3.03(Ft/s) Travel time = 3.63 min. TC = 21.09 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 34.751(CFS) 3.032(Ft/s) 1112 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.257(In/Hr) Rainfall intensity = 2.528(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.809 Subarea runoff = 17.710(CFS) for 10.000(Ac.) a Total runoff = 40.877(CFS) Effective area this stream = 20.00(Ac.) " Total Study Area (Main Stream No. 1) = 98.00(Ac.) Area averaged Fm value = 0.257(In/Hr) Street flow at end of street = 40.877(CFS) Half street flow at end of street = 20.439(CFS) Depth of flow = 0.608(Ft.), Average velocity = 3.233(Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) a� ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 729.000 to Point/Station 729.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 3 Stream flow area = 20.000(Ac.) Runoff from this stream = 40.877(CFS) Time of concentration = 21.09 min. Rainfall intensity = 2.528(In/Hr) Area averaged loss rate (Fm) = 0.2569(In/Hr) Area averaged Pervious ratio (Ap) = 0.3500 Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) dr do ,. r .r AV s INN rr �r r w IN a 1 151.455 20.72 2.555 2 19.874 23.79 2.352 3 40.877 21.09 2.528 Qmax (1) _ 1.000 * 1.000 * 151.455) + 1.101 * 0.871 * 19.874) + 1.012 * 0.982 * 40.877) + = 211.148 Qmax (2 ) _ 0.916 * 1.000 * 151.455) + 1.000 * 1.000 * 19.874) + 0.922 * 1.000 * 40.877) + = 196.296 Qmax(3) _ 0.989 * 1.000 * 151.455) + 1.088 * 0.886 * 19.874) + 1.000 * 1.000 * 40.877) + = 209.785 Total of 3 streams to confluence: Flow rates before confluence point: 151.455 19.874 40.877 Maximum flow rates at confluence using above data: 211.148 196.296 209.785 Area of streams before confluence: 65.867 10.000 20.000 Effective area values after confluence: 94.219 95.867 94.732 Results of confluence: Total flow rate = 211.148(CFS) Time of concentration = 20.717 min. Effective stream area after confluence = 94.219(Ac.) Stream Area average Pervious fraction(Ap) = 0.203 Stream Area average soil loss rate(Fm) = 0.181(In/Hr) Study area (this main stream) = 95.87(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 34.000 to Point/Station 35.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1048.200(Ft.) Downstream point/station elevation = 1042.000(Ft.) Pipe length = 660.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 211.148(CFS) Given pipe size = 39.00(In.) NOTE: Normal flow is pressure flow in user selected pipe size. The approximate hydraulic grade line above the pipe invert is 52.036(Ft.) at the headworks or inlet of the pipe(s) Pipe friction loss = 43.146(Ft.) Minor friction loss = 15.089(Ft.) K -factor = 1.50 Pipe flow velocity = 25.45(Ft/s) Travel time through pipe = 0.43 min. Time of concentration (TC) = 21.15 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 35.000 to Point/Station 35.000 **** CONFLUENCE OF MINOR STREAMS **** - Along Main Stream number: 1 in normal stream number 1 1114 Stream flow area = 94.219(Ac.) Runoff from this stream = 211.148(CFS) Time of concentration = 21.15 min. Rainfall intensity = 2.524(In/Hr) Area averaged loss rate (Fm) = 0.1812(In/Hr) Area averaged Pervious ratio (Ap) = 0.2035 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 730.000 to Point/Station 731.000 **** INITIAL AREA EVALUATION **** CONDOMINIUM subarea type Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1063.700(Ft.) Bottom (of initial area) elevation = 1055.800(Ft.) Difference in elevation = 7.900(Ft.) Slope = 0.00790 s(%)= 0.79 TC = k(0.360)*[(length-3)/(elevation change)]"0.2 Initial area time of concentration = 15.024 min. Rainfall intensity = 3.099(In/Hr) for a 100.0 Effective runoff coefficient used for area (Q=KCIA) Subarea runoff = 12.788(CFS) Total initial stream area = 5.000(Ac.) Pervious area fraction = 0.350 Initial area Fm value = 0.257(In/Hr) 0.257(In/Hr) year storm is C = 0.825 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 731.000 to Point/Station 732.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1055.800(Ft.) End of street segment elevation = 1053.600(Ft.) Length of street segment = 330.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.472(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 18.840(Ft.) Flow velocity = 2.65(Ft/s) 19.181(CFS) 2.649(Ft/s) an 1115 M Travel time = 2.08 min. TC = 17.10 min. Ir Adding area flow to street CONDOMINIUM subarea type +� Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 ,r Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.257(In/Hr) Rainfall intensity = 2.867(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.819 Subarea runoff = 10.703 (CFS) for 5.000 (Ac. ) Total runoff = 23.491(CFS) Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 108.00(Ac.) Area averaged Fm value = 0.257(In/Hr) Street flow at end of street = 23.491(CFS) Half street flow at end of street = 11.745(CFS) Depth of flow = 0.501(Ft.), Average velocity = 2.805(Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 732.000 to Point/Station 733.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1053.600(Ft.) End of street segment elevation = 1049.000(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) a Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 . Slope from grade break to crown (v/hz) = 0.020 Street flow is on (1] side(s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 ' Gutter width = 1.500(Ft.) s Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 r Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 35.236(CFS) Depth of flow = 0.717(Ft.), Average velocity = 3.590(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 2.53(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 31.112(Ft.) Flow velocity = 3.59(Ft/s) Travel time = 3.06 min. TC = 20.16 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 �' Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.257(In/Hr) BF. ,n Rainfall intensity = 2.597(In/Hr) for a 100.0 year storm mo runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.811 A Subarea runoff = 18.632(CFS) for 10.000(Ac.) Total runoff = 42.123(CFS) ■, Effective area this stream = 20.00(Ac.) Total Study Area (Main Stream No. 1) = 118.00(Ac.) Area averaged Fm value = 0.257(In/Hr) Street flow at end of street = 42.123(CFS) Half street flow at end of street = 42.123(CFS) �I Depth of flow = 0.764(Ft.), Average velocity = 3.664(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 4.87(Ft.) Flow width (from curb towards crown)= 33.450(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 733.000 to Point/Station 733.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 20.000(Ac.) * Runoff from this stream = 42.123(CFS) Time of concentration = 20.16 min. Rainfall intensity = 2.597(In/Hr) Area averaged loss rate (Fm) = 0.2569(In/Hr) Area averaged Pervious ratio (Ap) = 0.3500 Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) 1 211.148 21.15 2.524 2 42.123 20.16 2.597 Qmax (1) _ 1.000 * 1.000 * 211.148) + +� Qmax (2 ) _ 0.969 * 1.000 * 42.123) + = 251.952 1.031 * 0.953 * 211.148) + Id 1.000 * 1.000 * 42.123) + = 249.732 Total of 2 streams to confluence: Flow rates before confluence point: 211.148 42.123 Maximum flow rates at confluence using above data: ` 251.952 249.732 Area of streams before confluence: 94.219 20.000 Effective area values after confluence: 114.219 109.830 Results of confluence: Total flow rate = 251.952(CFS) Time of concentration = 21.149 min. Effective stream area after confluence = 114.219(Ac.) Stream Area average Pervious fraction(Ap) = 0.229 * Stream Area average soil loss rate(Fm) = 0.194(In/Hr) Study area (this main stream) = 114.22 Ac. End of computations, Total Study 118.00 (Ac.) Area = ( ) The following figures . g gores may no '117 as be used for a unit hydrograph study of the same area. Note: These figures do not consider reduced effective area effects caused by confluences in the rational equation. Area averaged pervious area fraction(Ap) = 0.227 * Area averaged SCS curve number = 40.1 do .. do w. Ad .. a 44 do .m M 40 ds .. a ,r arl ,rr r� 'INL 8 DZo6 RE ill SSD 0 1151 San Bernardino County Rational Hydrology Program (Hydrology Manual Date - August 1986) CIVILCADD/CIVILDESIGN Engineering Software, (c) 1989-2001 Version 6.4 Rational Hydrology Study Date: 09/02/04 ------------------------------------------------------------------------ FONTANA / TR 16678 LINE DZ -6 HYDROLOGY (REVISED) +� 100 YEAR STOEM JN 05086 CALCED BY : HERMAN HOVAGIMYAN 4d Hall & Forman, Inc. - SIN 950 ----------------------------------------------------------- s ********* Hydrology Study Control Information ********** ------------------------------------------------------------------------ Rational hydrology study storm event year is 100.0 10 Year storm 1 hour rainfall = 0.930(In.) 100 Year storm 1 hour rainfall = 1.350(In.) Computed rainfall intensity: Storm year = 100.00 1 hour rainfall = 1.350 (In.) Slope used for rainfall intensity curve b = 0.6000 r1 Soil antecedent moisture condition (AMC) = 2 me ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ s Process from Point/Station 717.000 to Point/Station 717.000 **** USER DEFINED FLOW INFORMATION AT A POINT **** Im Soil classification AP and SCS values input by user dr USER INPUT of soil data for subarea SCS curve number for soil(AMC 2) = 31.61 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Rainfall intensity = 2.733(In/Hr) for a 100.0 year storm User specified values are as follows: TC = 18.52 min. Rain intensity = 2.73(In/Hr) Total area this stream = 38.00(Ac.) r1 Total Study Area (Main Stream No. 1) = 38.00(Ac.) Total runoff = 90.13(CFS) w ,s++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 717.000 to Point/Station 33.000 w **** PIPEFLOW TRAVEL TIME (Program estimated size) **** Upstream point/station elevation = 1075.000(Ft.) Downstream point/station elevation = 1060.200(Ft.) Pipe length = 1060.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 90.130(CFS) Nearest computed pipe diameter = 39.00(In.) Calculated individual pipe flow = 90.130(CFS) Normal flow depth in pipe = 29.58(In.) A Flow top width inside pipe = 33.39(In.) Critical Depth = 35.16(In.) a, Pipe flow velocity = 13.35(Ft/s) Travel time through pipe = 1.32 min. Time of concentration (TC) = 19.84 min. in do 1152 10 �. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ „* Process from Point/Station 33.000 to Point/Station 34.000 **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 40 Upstream point/station elevation = 1060.200(Ft.) Downstream point/station elevation = 1048.200(Ft.) Pipe length = 1000.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 90.130(CFS) Nearest computed pipe diameter = 39.00(In.) Calculated individual pipe flow = 90.130(CFS) Normal flow depth in pipe = 31.88(In. „* Flow top width inside pipe = 30.14(In.) Critical Depth = 35.16(In.) Pipe flow velocity = 12.43(Ft/s) Travel time through pipe = 1.34 min. " Time of concentration (TC) = 21.18 min. ■ ,.,++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 34.000 to Point/Station 34.100 **** PIPEFLOW TRAVEL TIME (Program estimated size) **** Upstream point/station elevation = 1048.200(Ft.) Downstream point/station elevation = 1042.700(Ft.) Pipe length = 470.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 90.130(CFS) Nearest computed pipe diameter = 39.00(In.) Calculated individual pipe flow = 90.130(CFS) Normal flow depth in pipe = 32.30(In.) Flow top width inside pipe = 29.43(In.) Critical Depth = 35.16(In.) Pipe flow velocity = 12.27(Ft/s) Travel time through pipe = 0.64 min. Time of concentration (TC) = 21.82 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 34.100 to Point/Station 34.100 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 38.000(Ac.) Runoff from this stream = 90.130(CFS) Time of concentration = 21.82 min. Rainfall intensity = 2.477(In/Hr) �. Area averaged loss rate (Fm) = 0.0980(In/Hr) Area averaged Pervious ratio (Ap) = 0.1000 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 34.100 to Point/Station 34.100 **** USER DEFINED FLOW INFORMATION AT A POINT **** Soil classification AP and SCS values input by user USER INPUT of soil data for subarea „ SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5700 Max loss rate(Fm)= 0.557(In/Hr) Rainfall intensity = 3.397(In/Hr) for a 100.0 year storm User specified values are as follows: i .. 4M TC = 12.89 min. Rain intensity = 3.40(In/Hr) Total area this stream = 57.60(Ac.) „ Total Study Area (Main Stream No. 1) = 95.60(Ac.) Total runoff = 114.60(CFS) M++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ do Process from Point/Station 34.100 to Point/Station 34.100 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 57.600(Ac.) „ Runoff from this stream = 114.600(CFS) Time of concentration = 12.89 min. Rainfall intensity = 3.397(In/Hr) Area averaged loss rate (Fm) = 0.5574(In/Hr) Area averaged Pervious ratio (Ap) = 0.5700 �r Summary of stream data: �* Stream Flow rate TC Rainfall Intensity rr No. (CFS) (min) (In/Hr) 1 90.130 21.82 2.477 2 114.600 12.89 3.397 Qmax(1) _ 1.000 * 1.000 * 90.130) + 0.676 * 1.000 * 114.600) + = 167.596 Qmax (2 ) _ 1.387 * 0.591 * 90.130) + 1.000 * 1.000 * 114.600) + = 188.429 .r Total of 2 streams to confluence: Flow rates before confluence point: r 90.130 114.600 Maximum flow rates at confluence using above data: °* 167.596 188.429 Area of streams before confluence: 38.000 57.600 Effective area values after confluence: 95.600 80.045 do Results of confluence: Total flow rate = 188.429(CFS) Time of concentration = 12.890 min. Effective stream area after confluence = 80.045(Ac.) Stream Area average Pervious fraction(Ap) = 0.383 Stream Area average soil loss rate(Fm) = 0.375(In/Hr) Study area (this main stream) = 95.60(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 34.100 to Point/Station 34.200 **** PIPEFLOW TRAVEL TIME (Program estimated size) **** Upstream point/station elevation = 1041.700(Ft.) Downstream point/station elevation = 1041.300(Ft.) Pipe length = 40.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 188.429(CFS) Nearest computed pipe diameter = 54.00(In.) Calculated individual pipe flow = 188.429(CFS) ,r Normal flow depth in pipe = 42.38(In.) Flow top width inside pipe = 44.39(In.) Critical Depth = 47.46(In.) Pipe flow velocity = 14.08(Ft/s) Travel time through pipe = 0.05 min. Time of concentration (TC) = 12.94 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 34.200 to Point/Station 34.200 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 80.045(Ac.) Runoff from this stream = 188.429(CFS) Time of concentration = 12.94 min. Rainfall intensity = 3.389 (In/Hr) „r Area averaged loss rate (Fm) = 0.3748(In/Hr) Area averaged Pervious ratio (Ap) = 0.3832 ■ ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 720.100 to Point/Station 720.000 **** INITIAL AREA EVALUATION **** COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Initial subarea data: Initial area flow distance = 990.000(Ft.) . Top (of initial area) elevation = 1082.700(Ft.) Bottom (of initial area) elevation = 1072.800(Ft.) Difference in elevation = 9.900(Ft.) Slope = 0.01000 s(a)= 1.00 TC = k(0.304)*[(length"3)/(elevation change)]"0.2 Initial area time of concentration = 12.054 min. Rainfall intensity = 3.536(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.875 Subarea runoff = 15.473(CFS) " Total initial stream area = 5.000(Ac.) Pervious area fraction = 0.100 Initial area Fm value = 0.098(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 720.000 to Point/Station 721.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1076.100(Ft.) End of street segment elevation = 1072.800(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 30.000(Ft.) Distance from crown to crossfall grade break = 28.500(Ft.) Slope from gutter to grade break (v/hz) = 0.093 Slope from grade break to crown (v/hz) = 0.020 F F L 0 0 k Id 0 I I65 Street flow is on [1] side (s) of the street Distance from curb to property line = 12.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.680(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 30.947(CFS) Depth of flow = 0.737(Ft.), Average velocity = 3.090(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 30.000(Ft.) Flow velocity = 3.09(Ft/s) Travel time = 3.56 min. TC = 15.61 min. Adding area flow to street COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 3.52(Ft.) 0. 098 (In/Hr) Rainfall intensity = 3.028(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.871 Subarea runoff = 24.081(CFS) for 10.000(Ac.) Total runoff = 39.554(CFS) Effective area this stream = 15.00(Ac.) Total Study Area (Main Stream No. 1) = 110.60(Ac.) Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 39.554(CFS) Half street flow at end of street = 39.554(CFS) Depth of flow = 0.793(Ft.), Average velocity = 3.302(Ft/s) Warning: depth of flow exceeds top of curb Note: depth of flow exceeds top of street crown. Distance that curb overflow reaches into property = 6.32(Ft.) Flow width (from curb towards crown)= 30.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 721.000 to Point/Station 722.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1073.000(Ft.) Encs of street segment elevation = 1067.200(Ft.) Length of street segment = 400.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 32.000(Ft.) Distance from crown to crossfall grade break = 30.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street Distance from curb to property line = 14.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 1 ji Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 .m Estimated mean flow rate at midpoint of street = 40.213(CFS) Depth of flow = 0.656(Ft.), Average velocity = 5.063(Ft/s) 49 Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 28.055(Ft.) Flow velocity = 5.06(Ft/s) Travel time = 1.32 min. TC = 16.93 min. Adding area flow to street COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= The area added to the existing stream causes a a lower flow rate of Q = 38.870(CFS) therefore the upstream flow rate of Q = 39.554(CFS; Rainfall intensity = 2.884(In/Hr) for a 100.0 ye Effective runoff coefficient used for area,(total area rational method)(Q=KCIA) is C = 0.869 Subarea runoff = 0.000(CFS) for 0.500(Ac.) Total runoff = 39.554(CFS) Effective area this stream = 15.50(Ac.) Total Study Area (Main Stream No. 1) = 111.10(Ac.) Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 39.554(CFS) Half street flow at end of street = 39.554(CFS) D 4-'k -F fl 0.098 (In/Hr) is being used ar storm with modified ep o ow = 0.653(Ft.), Average velocity = 5.042(Ft/s) Flow width (from curb towards crown)= 27.880(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 722.000 to Point/Station 729.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1067.200(Ft.) End of street segment elevation = 1055.200(Ft.) Length of street segment = 1000.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 32.000(Ft.) Distance from crown to crossfall grade break = 30.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street * Distance from curb to property line = 14.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 ' Estimated mean flow rate at midpoint of street = 41.276(CFS) ;o Depth of flow = 0.687(Ft.), Average velocity = 4.673(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 1.00(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 29.583(Ft.) Flow velocity = 4.67(Ft/s) do Travel time = 3.57 min. TC = 20.50 min. Adding area flow to street 140 COMMERCIAL subarea type di Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= The area added to the existing stream causes a a lower flow rate of Q = 37.515(CFS) they f h 0.098 (In/Hr) I (57 e ore t e upstream flow rate of Q = 39.554(CFS) is being used Rainfall intensity = 2.572(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.866 Subarea runoff = 0.000(CFS) for 1.350(Ac.) Total runoff = 39.554(CFS) Effective area this stream = 16.85(Ac.) Total Study Area (Main Stream No. 1) = 112.45(Ac.) *� Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 39.554(CFS) Half street flow at end of street = 39.554(CFS) Depth of flow = 0.675(Ft.), Average velocity = 4.665(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 0.41(Ft.) Flow width (from curb towards crown)= 28.992(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ #. Process from Point/Station 729.000 to Point/Station 733.100 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1055.200(Ft.) End of street segment elevation = 1049.000(Ft.) Length of street segment = 490.000(Ft.) Height of curb above gutter flowline = 8.0(In.) -" Width of half street (curb to crown) = 32.000(Ft.) Distance from crown to crossfall grade break = 30.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side(s) of the street Distance from curb to property line = 14.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.673(Ft.), Average velocity = Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 28.888(Ft.) Flow velocity = 4.79(Ft/s) Travel time = 1.71 min. TC = 22.20 min. Adding area flow to street COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 40.317(CFS) 4.790(Ft/s) 0.30 (Ft.) Im 4M Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) The area added to the existing stream causes a a lower flow rate of Q = 37.067(CFS) therefore the upstream flow rate of Q = 39.554(CFS) is being used Rainfall intensity = 2.451(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified �. rational method)(Q=KCIA) is C = 0.864 a Subarea runoff = 0.000(CFS) for 0.650(Ac.) Total runoff = 39.554(CFS) Effective area this stream = 17.50(Ac.) Total Study Area (Main Stream No. 1) = 113.10(Ac.) Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 39.554(CFS) Half street flow at end of street = 39.554(CFS) Depth of flow = 0.667(Ft.), Average velocity = 4.788(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 0.03(Ft.) Flow width (from curb towards crown)= 28.617(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 733.100 to Point/Station 733.100 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 17.500(Ac.) Runoff from this stream = 39.554(CFS) Time of concentration = 22.20 min. Rainfall intensity = 2.451(In/Hr) Area averaged loss rate (Fm) = 0.0978(In/Hr) Area averaged Pervious ratio (Ap) = 0.1000 Summary of stream data: •� Stream Flow rate TC Rainfall Intensity ar No. (CFS) (min) (In/Hr) 1 188.429 12.94 3.389 2 39.554 22.20 2.451 Qmax (1) _ 1.000 * 1.000 * 188.429) + 1.399 * 0.583 * 39.554) + = 220.664 Qmax ( 2 ) _ 0.689 * 1.000 * 188.429) + 1.000 * 1.000 * 39.554) + = 169.344 a Total of 2 streams to confluence: ' Flow rates before confluence point: 188.429 39.554 Maximum flow rates at confluence using above data: *� 220.664 169.344 Area of streams before confluence: 80.045 17.500 Effective area values after confluence: 90.243 97.545 Results of confluence: Total flow rate = 220.664(CFS) a Time of concentration = 12.937 min. 'r Effective stream area after confluence = 90.243(Ac.) ® Stream Area average Pervious fraction(Ap) = 0.332 Stream Area average soil loss rate(Fm) = 0.325(In/Hr) Study area (this main stream) = 97.55(Ac.) M ,o++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 34.200 to Point/Station 35.000 an **** PIPEFLOW TRAVEL TIME (Program estimated size) **** " Upstream point/station elevation = 1040.800(Ft.) Downstream point/station elevation = 1039.600(Ft.) Pipe length = 80.00(Ft.) Manning's N = 0.013 a No. of pipes = 1 Required pipe flow = 220.664(CFS) Nearest computed pipe diameter = 54.00(In.) *� Calculated individual pipe flow = 220.664(CFS) Normal flow depth in pipe = 40.69(In.) Flow top width inside pipe = 46.55(In.) Critical Depth = 49.89(In.) Pipe flow velocity = 17.17(Ft/s) Travel time through pipe = 0.08 min. Time of concentration (TC) = 13.01 min. End of computations, Total Study Area = 113.10 (Ac.) r The following figures may be used for a unit hydrograph study of the same area. *� Note: These figures do not consider reduced effective area effects caused by confluences in the rational equation. Area averaged pervious area fraction(Ap) = 0.339 Area averaged SCS curve number = 31.9 go 49 qm 49 �r 7M San Bernardino County Rational Hydrology Program (Hydrology Manual Date - August 1986) CIVILCADD/CIVILDESIGN Engineering Software, (c) 1989-2001 Version 6.4 Rational Hydrology Study Date: 09/21/04 ------------------------------------------------------------------------ FONTANA / LINE DZ -7 HYDROLOGY 100 YEAR STORM JN 04339 ,rr ------------------------------------------------------------------------ Hall & Forman, Inc. - SIN 950 ------------------------------------------------------------------------ ********* Hydrology Study Control Information ********** ------------------------------------------------------------------------ '� Rational hydrology study storm event year is 100.0 10 Year storm 1 hour rainfall = 0.930(In.) 100 Year storm 1 hour rainfall = 1.350(In.) Computed rainfall intensity: Storm year = 100.00 1 hour rainfall = 1.350 (In.) Slope used for rainfall intensity curve b = 0.6000 Soil antecedent moisture condition (AMC) = 2 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 800.000 to Point/Station 801.000 **** INITIAL AREA EVALUATION **** +� COMMERCIAL subarea type Decimal fraction soil group A = 1.000 �* Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1098.000(Ft.) Bottom (of initial area) elevation = 1088.000(Ft.) Difference in elevation = 10.000(Ft.) �. Slope = 0.01000 S(%-)= 1.00 TC = k(0.304)*[(length"3)/(elevation change)1^0.2 Initial area time of concentration = 12.102 min. Rainfall intensity = 3.528(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.875 Subarea runoff = 18.522(CFS) Total initial stream area = 6.000(Ac.) ' Pervious area fraction = 0.100 Initial area Fm value = 0.098(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 801.000 to Point/Station 802.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** al Top of street segment elevation = 1088.000(Ft.) End of street segment elevation = 1081.000(Ft.) r- _-0.0 �-� 1202 Length of street segment = 820.000(Ft.) Height of curb above gutter flowline = 8. 0 (In. ) Width of half street (curb to crown) = 20.000(Ft.) .. Distance from crown to crossfall grade break = 18.500(Ft.) rr Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 '• Street flow is on [2] side (s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 ,. Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) 40 Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 40 Manning's N from grade break to crown = 0.0150 ,r Estimated mean flow rate at midpoint of street = 33.957(CFS) Depth of flow = 0.534(Ft.), Average velocity = 3.498(Ft/s) Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 3.50(Ft/s) Travel time = 3.91 min. TC = 16.01 min. '" Adding area flow to street COMMERCIAL subarea type " Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 . Decimal fraction soil group D = 0.000 ■ SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Rainfall intensity = 2.983(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.870 Subarea runoff = 23.020(CFS) for 10.000(Ac.) Total runoff = 41.542(CFS) Effective area this stream = 16.00(Ac.) Total Study Area (Main Stream No. 1) = 16.00(Ac.) ., Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 41.542(CFS) Half street flow at end of street = 20.771(CFS) Depth of flow = 0.565(Ft.), Average velocity = 3.790(Ft/s) Note: depth of flow exceeds top of street crown. a Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 802.000 to Point/Station 803.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** am Top of street segment elevation = 1081.000(Ft.) End of street segment elevation = 1075.000(Ft.) 40 Length of street segment = 620.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) 1203 im Gutter hike from flowline = 1.500(In.) in Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 i` Manning's N from grade break to crown = 0.0150 +n Estimated mean flow rate at midpoint of street = 67.506(CFS) Depth of flow = 0.844(Ft.), Average velocity = 4.529(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 8.89(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 37.474(Ft.) Flow velocity = 4.53(Ft/s) Travel time = 2.28 min. TC = 18.29 min. Adding area flow to street ' COMMERCIAL subarea type rr Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 �► Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Rainfall intensity = 2.753(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.868 Subarea runoff = 44.503(CFS) for 20.000(Ac.) Total runoff = 86.045(CFS) Effective area this stream = 36.00(Ac.) 4. Total Study Area (Main Stream No. 1) = 36.00(Ac.) Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 86.045(CFS) Half street flow at end of street = 86.045(CFS) Depth of flow = 0.910(Ft.), Average velocity = 4.736(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 12.18(Ft.) Flow width (from curb towards crown)= 40.759(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 803.000 to Point/Station 36.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1069.000(Ft.) Downstream point/station elevation = 1054.000(Ft.) Pipe length = 990.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 86.045(CFS) Given pipe size = 36.00(In.) Calculated individual pipe flow = 86.045(CFS) Normal flow depth in pipe = 31.41(In.) Flow top width inside pipe = 24.02(In.) Critical Depth = 33.83(In.) Pipe flow velocity = 13.16(Ft/s) Travel time through pipe = 1.25 min. Time of concentration (TC) = 19.54 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 36.000 to Point/Station 36.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 36.000(Ac.) ,. Runoff from this stream = 86.045(CFS) AN Time of concentration = 19.54 min. Rainfall intensity = 2.646(In/Hr) �. Area averaged loss rate (Fm) = 0.0978(In/Hr) ,rr Area averaged Pervious ratio (Ap) = 0.1000 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 804.000 to Point/Station 805.000 ,., **** INITIAL AREA EVALUATION **** COMMERCIAL subarea type Decimal fraction soil group A = 1.000 ' Decimal fraction soil group B = 0.000 �r Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1081.500(Ft.) Bottom (of initial area) elevation = 1071.000(Ft.) Difference in elevation = 10.500(Ft.) Slope = 0.01050 s (%) = 1.05 TC = k(0.304)*[(length^3)/(elevation change)] -0.2 Initial area time of concentration = 11.985 min. Rainfall intensity = 3.548(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.875 ' Subarea runoff = 15.528(CFS) Total initial stream area = 5.000(Ac.) Pervious area fraction = 0.100 Initial area Fm value = 0.098(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 805.000 to Point/Station 806.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1071.000(Ft.) End of street segment elevation = 1069.000(Ft.) Length of street segment = 330.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) �• Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side (s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500 (In. ) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 23.292(CFS) Depth of flow = 0.506(Ft.), Average velocity = 2.716(Ft/s) Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: +� Halfstreet flow width = 20.000(Ft.) Flow velocity = 2.72(Ft/s) m 1205 Travel time = 2.02 min. TC = 14.01 min. Adding area flow to street COMMERCIAL subarea type Decimal fraction soil group A = 1.000 ai Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Rainfall intensity = 3.231(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.873 Subarea runoff = 12.673(CFS) for 5.000(Ac.) Total runoff = 28.201(CFS) Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 46.00(Ac.) Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 28.201(CFS) Half street flow at end of street = 14.100(CFS) Depth of flow = 0.532(Ft.), Average velocity = 2.931(Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 806.000 to Point/Station 807.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1069.000(Ft.) End of street segment elevation = 1065.000(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2 ] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.599(Ft.), Average velocity = Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 3.44(Ft/s) Travel time = 3.20 min. TC = 17.21 min. Adding area flow to street RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 42.301(CFS) 3.442(Ft/s) air Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) Rainfall intensity = 2.856(In/Hr) for a 100.0 year storm ZI r, Effective runoff coefficient used for area (total area with modified rational method)(Q=KCIA) is C = 0.808 Subarea runoff = 17.935(CFS) for 10.000(Ac.) Total runoff = 46.136(CFS) s Effective area this stream = 20.00(Ac.) Total Study Area (Main Stream No. 1) = 56.00(Ac.) Area averaged Fm value = 0.293(In/Hr) Street flow at end of street = 46.136(CFS) Half street flow at end of street = 23.068(CFS) Depth of flow = 0.615(Ft.), Average velocity = 3.563(Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) .s ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 807.000 to Point/Station 808.000 *w **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1065.000(Ft.) End of street segment elevation = 1060.000(Ft.) Length of street segment = 330.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) " Distance from crown to crossfall grade break = 40.500(Ft.) „r Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 .. Street flow is on [1] side (s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) .r Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 *� Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 57.669(CFS) Depth of flow = 0.745(Ft.), Average velocity = 5.352(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 3.90(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 32.485(Ft.) Flow velocity = 5.35(Ft/s) ,rr Travel time = 1.03 min. TC = 18.23 min. Adding area flow to street ®a RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) Rainfall intensity = 2.759(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.783 Subarea runoff = 18.669 (CFS) for 10 .000 (Ac. ) Total runoff = 64.805(CFS) Effective area this stream = 30.00(Ac.) Total Study Area (Main Stream No. 1) = 66.00(Ac.) Area averaged Fm value = 0.359(In/Hr) A Street flow at end of street = 64.805(CFS) Half street flow at end of street = 64.805(CFS) a it s ar 4d Depth of flow = 0.775(Ft.), Average velocity = Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = Flow width (from curb towards crown)= 34.003(Ft.) 5.433(Ft/s) 5.42 (Ft.) i'2,� ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 808.000 to Point/Station 808.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 30.000(Ac.) Runoff from this stream = 64.805(CFS) Time of concentration = 18.23 min. Rainfall intensity = 2.759(In/Hr) Area averaged loss rate (Fm) = 0.3585(In/Hr) Area averaged Pervious ratio (Ap) = 0.3667 Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) ar ® 1 86.045 19.54 2.646 A 2 64.805 18.23 2.759 Qmax (1) _ •,� 1.000 * 1.000 * 86.045) + 0.953 * 1.000 * 64.805) + = 147.810 Qmax (2 ) _ 1.044 * 0.933 * 86.045) + 1.000 * 1.000 * 64.805) + = 148.623 Total of 2 streams to confluence: Flow rates before confluence point: 86.045 64.805 Maximum flow rates at confluence using above data: 147.810 148.623 Area of streams before confluence: 36.000 30.000 Effective area values after confluence: ' 66.000 63.585 ai Results of confluence: Total flow rate = 148.623(CFS) Time of concentration = 18.233 min. Effective stream area after confluence = 63.585(Ac.) Stream Area average Pervious fraction(Ap) = 0.221 Stream Area average soil loss rate(Fm) = 0.216(In/Hr) Study area (this main stream) = 66.00(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 36.000 to Point/Station 37.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1054.000(Ft.) Downstream point/station elevation = 1043.500(Ft.) Pipe length = 990.00(Ft.) Manning's N,= 0.013 No. of pipes = 1 Required pipe flow = 148.623(CFS) At Given pipe size = 42.00(In.) NOTE: Normal flow is pressure flow in user selected pipe size. AV '? CO E .� The approximate hydraulic grade line above the pipe invert is 16.655(Ft.) at the headworks or inlet of the pipe(s) Pipe friction loss = 21.597(Ft.) Minor friction loss = 5.558(Ft.) K-factor = 1.50 ar Pipe flow velocity = 15.45(Ft/s) Travel time through pipe = 1.07 min. ** Time of concentration (TC) = 19.30 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 37.000 to Point/Station 37.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 ■ Stream flow area = 63.585(Ac.) Runoff from this stream = 148.623(CFS) Time of concentration = 19.30 min. do Rainfall intensity = 2.666(In/Hr) Area averaged loss rate (Fm) = 0.2163(In/Hr) Area averaged Pervious ratio (Ap) = 0.2212 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 809.000 to Point/Station 810.000 **** INITIAL AREA EVALUATION **** w RESIDENTIAL(5 - 7 dwl/acre) A Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) "* Initial subarea data: A Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1068.000(Ft.) Bottom (of initial area) elevation = 1061.000(Ft.) Difference in elevation = 7.000(Ft.) do Slope = 0.00700 s(%-)= 0 .70 TC = k(0.389)*[(length"3)/(elevation change)]-0.2 Initial area time of concentration = 16.631 min. ai Rainfall intensity = 2.915(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.749 Ae Subarea runoff = 10.918(CFS) Total initial stream area = 5.000(Ac.) Pervious area fraction = 0.500 Initial area Fm value = 0.489(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 810.000 to Point/Station 811.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** �. Top of street segment elevation = 1061.000(Ft.) End of street segment elevation = 1057.000(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) +� Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 201 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side (s) of the street 4" Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 ,. Estimated mean flow rate at midpoint of street = 16.377(CFS) Depth of flow = 0.456(Ft.), Average velocity = 2.458(Ft/s) " Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 18.057(Ft.) on Flow velocity = 2.46(Ft/s) A Travel time = 4.48 min. TC = 21.11 min. Adding area flow to street *� RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) Rainfall intensity = 2.527(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.726 �* Subarea runoff = 7.422(CFS) for 5.000(Ac.) Total runoff = 18.341(CFS) " Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 76.00(Ac.) Area averaged Fm value = 0.489(In/Hr) " Street flow at end of street = 18.341(CFS) Half street flow at end of street = 9.170(CFS) Depth of flow = 0.472(Ft.), Average velocity = 2.527(Ft/s) Flow width (from curb towards crown)= 18.860(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 811.000 to Point/Station 812.000 a. **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** �r Top of street segment elevation = 1057.000(Ft.) End of street segment elevation = 1051.000(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street ' Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) •. Gutter hike from flowline 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 36.682(CFS) Depth of flow = 0.692(Ft.), Average velocity = 4.072(Ft/s) Warning: depth of flow exceeds top of curb i �. Distance that curb overflow reaches into property = 1.28(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 29.868(Ft.) Flow velocity = 4.07(Ft/s) AV Travel time = 2.70 min. TC = 23.81 min. Adding area flow to street SCHOOL subarea Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.6000 Max loss rate(Fm)= 0.587(In/Hr) Rainfall intensity = 2.351(In/Hr) for a 100.0 year storm ,e Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.688 Subarea runoff = 30.165(CFS) for 20.000(Ac.) Total runoff = 48.506(CFS) Effective area this stream = 30.00(Ac.) Total Study Area (Main Stream No. 1) = 96.00(Ac.) Area averaged Fm value = 0.554(In/Hr) Street flow at end of street = 48.506(CFS) Half street flow at end of street = 48.506(CFS) Depth of flow = 0.766(Ft.), Average velocity = 4.189(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 4.97(Ft.) „ Flow width (from curb towards crown) = 33.558 (Ft. ) ■ ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 812.000 to Point/Station 812.000 a�f **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 30.000(Ac.) Runoff from this stream = 48.506(CFS) Time of concentration = 23.81 min. Rainfall intensity = 2.351(In/Hr) Area averaged loss rate (Fm) = 0.5541(In/Hr) Area averaged Pervious ratio (Ap) = 0.5667 ' Summary of stream data: Stream Flow rate TC Rainfall Intensity r No. (CFS) (min) (In/Hr) AV 1 148.623 19.30 2.666 2 48.506 23.81 2.351 Id Qmax (1) _ 1.000 * 1.000 * 148.623) + " 1.176 * 0.811 * 48.506) + = 194.851 Qmax (2 ) _ 0.871 * 1.000 * 148.623) + .. 1.000 * 1.000 * 48.506) + = 177.992 °r Total of 2 streams to confluence: Flow rates before confluence point: 148.623 48.506 a Maximum flow rates at confluence using above -data: 194.851 177.992 40 Area of streams before confluence: 63.585 30.000 Effective area values after confluence: 87.905 93.585 ,rr Results of confluence: Total flow rate = 194.851(CFS) re Time of concentration = 19.301 min. Effective stream area after confluence = 87.905(Ac.) Stream Area average Pervious fraction(Ap) = 0.332 Stream Area average soil loss rate(Fm) = 0.325(In/Hr) Study area (this main stream) = 93.58(Ac.) ,r ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 37.000 to Point/Station 38.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1043.500(Ft.) Downstream point/station elevation = 1038.000(Ft.) Pipe length = 660.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 194.851(CFS) Given pipe size = 42.00(In.) NOTE: Normal flow is pressure flow in user selected pipe size. �* The approximate hydraulic grade line above the pipe invert is 28.801(Ft.) at the headworks or inlet of the pipe(s) Pipe friction loss = 24.747(Ft.) Minor friction loss = 9.553(Ft.) K -factor = 1.50 Pipe flow velocity = 20.25(Ft/s) Travel time through pipe = 0.54 min. Time of concentration (TC) = 19.84 min. M ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -� Process from Point/Station 38.000 to Point/Station 38.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 87.905(Ac.) Runoff from this stream = 194.851(CFS) Time of concentration = 19.84 min. Rainfall intensity = 2.622(In/Hr) 49 Area averaged loss rate (Fm) = 0.3246(In/Hr) Area averaged Pervious ratio (Ap) = 0.3320 El ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 813.000 to Point/Station 814.000 **** INITIAL AREA EVALUATION **** a CONDOMINIUM subarea type *' Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342(In/Hr) Initial subarea data: ® Initial area flow distance = 1000.000(Ft.) ,. Top (of initial area) elevation = 1056.600(Ft.) Bottom (of initial area) elevation = 1048.500(Ft.) Difference in elevation = 8.100(Ft.) Slope = 0.00810 s(o)= 0.81 TC = k(0.360)*[(length"3)/(elevation change)]"0.2 " Initial area time of concentration = 14.949 min. �r Rainfall intensity = 3.108(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.801 +� Subarea runoff = 12.445(CFS) Total initial stream area = 5.000(Ac.) Pervious area fraction = 0.350 Initial area Fm value = 0.342(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 814.000 to Point/Station 815.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1048.500(Ft.) End of street segment elevation = 1047.300(Ft.) Length of street segment = 330.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side (s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.510(Ft.), Average velocity = Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 2.13(Ft/s) Travel time = 2.58 min. TC = 17.53 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 18.668(CFS) 2.133(Ft/s) Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342(In/Hr) Rainfall intensity = 2.825(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.791 Subarea runoff = 9.898 (CFS) for 5.000 (Ac. ) Total runoff = 22.343(CFS) Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 106.00(Ac.) Area averaged Fm value = 0.342(In/Hr) Street flow at end of street = 22.343(CFS) Half street flow at end of street = 11.172(CFS) Depth of flow = 0.535(Ft.), Average velocity = 2.290(Ft/s) A Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) I" F7 0 r- 12 [3 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 815.000 to Point/Station 816.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** �. Top of street segment elevation = 1047.300(Ft.) End of street segment elevation = 1045.000(Ft.) ' Length of street segment = 660.000(Ft.) * Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side (s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 33.515(CFS) Depth of flow = 0.607(Ft.), Average velocity = 2.656(Ft/s) Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 2.66(Ft/s) Travel time = 4.14 min. TC = 21.67 min. Adding area flow to street " CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342(In/Hr) Rainfall intensity = 2.487(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA).is C = 0.776 Subarea runoff = 16.267(CFS) for 10.000(Ac.) 40 Total runoff = 38.610(CFS) Effective area this stream = 20.00(Ac.) Total Study Area (Main Stream No. 1) = 116.00(Ac.) Area averaged Fm value = 0.342(In/Hr) Street flow at end of street = 38.610(CFS) Half street flow at end of street = 19.305(CFS) ' Depth of flow = 0.635(Ft.), Average velocity = 2.809(Ft/s) �r Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ IN Process from Point/Station 816.000 to Point/Station 816.000 **** CONFLUENCE OF MINOR STREAMS **** 40 Along Main Stream number: 1 in normal stream number 2 Stream flow area = 20.000(Ac.) Runoff from this stream = 38.610(CFS) Time of concentration = 21.67 min. a. r 12A Rainfall intensity = 2.487(In/Hr) Area averaged loss rate (Fm) = 0.3422(In/Hr) Area averaged Pervious ratio (Ap) = 0.3500 Summary of stream data: Stream Flow rate TC Rainfall Intensity # No. (CFS) (min) (In/Hr) s 1 194.851 19.84 2.622 2 38.610 21.67 2.487 � Qmax (1) _ 1.000 * 1.000 * 194.851) + 1.063 * 0.916 * 38.610) + = 232.432 Qmax (2 ) _ 0.941 * 1.000 * 194.851) + 1.000 * 1.000 * 38.610) + = 222.027 Total of 2 streams to confluence: Flow rates before confluence point: ' 194.851 38.610 +r Maximum flow rates at confluence using above data: 232.432 222.027 Area of streams before confluence: 87.905 20.000 Effective area values after confluence: 106.221 107.905 Results of confluence: Total flow rate = 232.432(CFS) Time of concentration = 19.845 min. Effective stream area after confluence = 106.221(Ac.) r Stream Area average Pervious fraction(Ap) = 0.335 Stream Area average soil loss rate(Fm) = 0.328(In/Hr) Study area (this main stream) = 107.91(Ac.) End of computations, Total Study Area = 116.00 (Ac.) The following figures may be used for a unit hydrograph study of the same area. Note: These figures do not consider reduced effective area effects caused by confluences in the rational equation. Area averaged pervious area fraction(Ap) = 0.333 V Area averaged SCS curve number = 32.0 a s A M 4d 40 A do do qm 40 MR As AN w 4. 49 1,300 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 701.000 to Point/Station 702.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1096.700(Ft.) End of street segment elevation = 1095.000(Ft.) 49 San Bernardino County Rational Hydrology Program (Hydrology Manual Date - August 1986) CIVILCADD/CIVILDESIGN Engineering Software, (c) 1989-2001 Version 6.4 Rational Hydrology Study Date: 08/10/04 -------------------------------------------------------- FONTANA / LINE DZ -5 HYDROLOGY 100 YEAR STORM JN 04339 �r ------------------------------------------------------------------------ Hall & Forman, Inc. - SIN 950 rr------------------------------------------------------------------------ ********* Hydrology Study Control Information ********** ------------------------------------------------------------- Rational hydrology study storm event year is 100.0 10 Year storm 1 hour rainfall = 0.930(In.) 100 Year storm 1 hour rainfall = 1.350(In.) Computed rainfall intensity: Storm year = 100.00 1 hour rainfall = 1.350 (In.) Slope used for rainfall intensity curve b = 0.6000 �r Soil antecedent moisture condition (AMC) = 2 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 700.000 to Point/Station 701.000 **** INITIAL AREA EVALUATION **** CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342(In/Hr) Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1104.000(Ft.) Bottom (of initial area) elevation = 1096.700(Ft.) Difference in elevation = 7.300(Ft.) Slope = 0.00730 s(%)= 0 .73 -0.2 TC = k(0.360)*[(length"3)/(elevation change)] Initial area time of concentration = 15.263 min. Rainfall intensity = 3.069(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.800 Subarea runoff = 12.272(CFS) Total initial stream area = 5.000(Ac.) Pervious area fraction = 0.350 41 Initial area Fm value = 0.342(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 701.000 to Point/Station 702.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1096.700(Ft.) End of street segment elevation = 1095.000(Ft.) 49 .. Length of street segment = 330.000(Ft.) IN Height of curb above gutter flowline = 8.0(In.) ,n Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side (s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.485(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 19.485(Ft.) Flow velocity = 2.38(Ft/s) Travel time = 2.31 min. TC = 17.57 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 18.408(CFS) 2.380(Ft/s) 0.342(In/Hr) Rainfall intensity = 2.820(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.791 Subarea runoff = 10.031(CFS) for 5.000(Ac.) Total runoff = 22.303(CFS) Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 10.00(Ac.) Area averaged Fm value = 0.342(In/Hr) Street flow at end of street = 22.303(CFS) Half street flow at end of street = 11.151(CFS) Depth of flow = 0.511(Ft.), Average velocity = 2.542(Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 702.000 to Point/Station 703.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1095.000(Ft.) End of street segment elevation = 1092.000(Ft.) Length of street segment = 660.000(Ft.) " Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) �r 1303 o. Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 33.454(CFS) Depth of flow = 0.582(Ft.), Average velocity = 2.876(Ft/s) Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 2.88(Ft/s) .w Travel time = 3.83 min. TC = 21.40 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342(In/Hr) Rainfall intensity = 2.506(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.777 ' Subarea runoff = 16.645 (CFS) for 10.000 (Ac. ) Total runoff = 38.948(CFS) Effective area this stream = 20.00(Ac.) Total Study Area (Main Stream No. 1) = 20.00(Ac.) Area averaged Fm value = 0.342(In/Hr) Street flow at end of street = 38.948(CFS) Half street flow at end of street = 19.474(CFS) Depth of flow = 0.610(Ft.), Average velocity = 3.054(Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 703.000 to Point/Station 704.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1092.000(Ft.) End of street segment elevation = 1082.000(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 A Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 M Estimated mean flow rate at midpoint of street = Depth of flow = 0.748(Ft.), Average velocity = Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 32.654(Ft.) Flow velocity = 5.36(Ft/s) 58.422(CFS) 5.360(Ft/s) 4.07 (Ft.) I 3d5 Travel time = 2.05 min. TC = 23.45 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342 (In/Hr} �. Rainfall intensity = 2.372(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.770 Subarea runoff = 34.124(CFS) for 20.000(Ac.) Total runoff = 73.072(CFS) + Effective area this stream = 40.00(Ac.) Total Study Area (Main Stream No. 1) = 40.00(Ac.) Area averaged Fm value = 0.342(In/Hr) Street flow at end of street = 73.072(CFS) Half street flow at end of street = 73.072(CFS) „ Depth of flow = 0.806(Ft.), Average velocity = 5.532(Ft/s) Warning: depth of flow exceeds top of curb ar Distance that curb overflow reaches into property = 6.98(Ft.) Flow width (from curb towards crown) = 35.567 (Ft. ) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ �* Process from Point/Station 704.000 to Point/Station 30.000 �I **** PIPEFLOW TRAVEL TIME (User specified size) **** ■„ Upstream point/station elevation = 1076.000(Ft.) Downstream point/station elevation = 1066.000(Ft.) Pipe length = 660.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 73.072(CFS) Given pipe size = 36.00(In.) r Calculated individual pipe flow = 73.072(CFS) Normal flow depth in pipe = 26.44(In.) a Flow top width inside pipe = 31.80(In.) Critical Depth = 32.37(In.) Pipe flow velocity = 13.12(Ft/s) Travel time through pipe = 0.84 min. Time of concentration (TC) = 24.29 min. A ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 30.000 to Point/Station 30.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 40.000(Ac.) Runoff from this stream = 73.072(CFS) ' Time of concentration = 24.29 min. +r Rainfall intensity = 2.323(In/Hr) Area averaged loss rate (Fm) = 0.3422(In/Hr) Area averaged Pervious ratio (AP) = 0.3500 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 705.000 to Point/Station 706.000 **** INITIAL AREA EVALUATION **** Lj CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio (Ap) = 0.3500 Max loss rate (Fm) = 0 .342 (In/Hr) Initial subarea data: Initial area flow distance = 1000.000(Ft.) .. Top (of initial area) elevation = 1085.700(Ft.) Bottom (of initial area) elevation = 1075.300(Ft.) Difference in elevation = 10.400(Ft.) Slope = 0.01040 s(o)= 1.04 TC = k(0.360)*[(length"3)/(elevation change)]"0.2 Initial area time of concentration = 14.220 min. Rainfall intensity = 3.202(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.804 Subarea runoff = 25.742(CFS) Total initial stream area = 10.000(Ac.) Pervious area fraction = 0.350 Initial area Fm value = 0.342(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 706.000 to Point/Station 707.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1075.300(Ft.) End of street segment elevation = 1072.000(Ft.) Length of street segment = 330.000 (Ft. ) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side (s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 '* Estimated mean flow rate at midpoint of street = 35.396(CFS) Depth of flow = 0.529(Ft.), Average velocity = 3.730(Ft/s) Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 3.73(Ft/s) Travel time = 1.47 min. TC = 15.69 min. Adding area flow to street RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 0.000 Decimal fraction soil group,B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.367(In/Hr) Rainfall intensity = 3.018(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified �r rational method)(Q=KCIA) is C = 0.795 Subarea runoff = 16.240(CFS) for 7.500(Ac.) Total runoff = 41.983(CFS) Effective area this stream = 17.50(Ac.) Total Study Area (Main Stream No. 1) = 57.50(Ac.) Area averaged Fm value = 0.353(In/Hr) Street flow at end of street = 41.983(CFS) Half street flow at end of street = 20.991(CFS) Depth of flow = 0.554(Ft.), Average velocity = 3.991(Ft/s) ,w Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) 40 w w rrt 13x7 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 707.000 to Point/Station 707.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 17.500(Ac.) Runoff from this stream = 41.983(CFS) Time of concentration = 15.69 min. Rainfall intensity = 3.018(In/Hr) Area averaged loss rate (Fm) = 0.3528(In/Hr) Area averaged Pervious ratio (Ap) = 0.4143 Summary of stream data: Stream Flow rate TC No. (CFS) (min) Rainfall Intensity (In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 30.000 to Point/Station 31.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** 1 73.072 24.29 2.323 2 41.983 15.69 3.018 Qmax (1) _ 1.000 * 1.000 * 73.072) + 0.739 * 1.000 * 41.983) + = 104.096 Qmax (2 ) _ 1.351 * 0.646 * 73.072) + 1.000 * 1.000 * 41.983) + = 105.786 ar Total of 2 streams to confluence: Flow rates before confluence point: 73.072 41.983 Maximum flow rates at confluence using above data: 104.096 105.786 Area of streams before confluence: 40.000 17.500 Effective area values after confluence: 57.500 43.345 Results of confluence: Total flow rate = 105.786(CFS) Time of concentration = 15.694 min. Effective stream area after confluence = 43.345(Ac.) Stream Area average Pervious fraction(Ap) = 0.370 Stream Area average soil loss rate(Fm) = 0.345(In/Hr) Study area (this main stream) = 57.50(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 30.000 to Point/Station 31.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** .r Upstream point/station elevation = 1066.000(Ft.) Downstream point/station elevation = 1062.200(Ft.) Pipe length = 990.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 105.786(CFS) Given pipe size = 39.00(In.) NOTE: Normal flow is pressure flow in user selected pipe size. ,.r The approximate hydraulic grade line above the pipe invert is 16.233(Ft.) at the headworks or inlet of the pipe(s) Pipe friction loss = 16.245(Ft.) Minor friction loss = 3.787(Ft.) K -factor = 1.50 Pipe flow velocity = 12.75(Ft/s) Travel time through pipe'= 1.29 min. Time of concentration (TC) = 16.99 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 31.000 to Point/Station 31.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 43.345(Ac.) Runoff from this stream = 105.786(CFS) Time of concentration = 16.99 min. +i Rainfall intensity = 2.878(In/Hr) Area averaged loss rate (Fm) = 0.3455(In/Hr) * Area averaged Pervious ratio (Ap) = 0.3696 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 708.000 to Point/Station 709.000 **** INITIAL AREA EVALUATION **** RESIDENTIAL(5 - 7 dwl/acre) A Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 . Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.367(In/Hr) Initial subarea data: 4A Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1072.000(Ft.) Bottom (of initial area) elevation = 1069.200(Ft.) Difference in elevation = 2.800(Ft.) Slope = 0.00280 s(o)= 0.28 TC = k (0 .389) * [ (length"3) / (elevation change)] -0.2 Initial area time of concentration = 19.976 min. Rainfall intensity = 2.612(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.774 Subarea runoff = 15.152(CFS) Total initial stream area = 7.500(Ac.) Pervious area fraction = 0.500 "* Initial area Fm value = 0.367(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 709.000 to Point/Station 710.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW�ADD.ITION **** ii in 10 AM 4d a r rr Top of street segment elevation = 1069.200(Ft.) End of street segment elevation = 1062.600(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on (1] side (s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.669(Ft.), Average velocity = Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 28.694(Ft.) Flow velocity = 4.26(Ft/s) Travel time = 2.58 min. TC = 22.56 min. Adding area flow to street RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 35.354(CFS) 4.257(Ft/s) 0.11(Ft.) 130` Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.367(In/Hr) Rainfall intensity = 2.428(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.764 Subarea runoff = 35.855(CFS) for 20.000(Ac.) Total runoff = 51.006(CFS) Effective area this stream = 27.50(Ac.) Total Study Area (Main Stream No. 1) = 85.00(Ac.) Area averaged Fm value = 0.367(In/Hr) Street flow at end of street = 51.006(CFS) Half street flow at end of street = 51.006(CFS) Depth of flow = 0.767(Ft.), Average velocity = 4.395(Ft/s) '■ Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 5.01(Ft.) Flow width (from curb towards crown)= 33.591(Ft.) .e '++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 710.000 to Point/Station 710.000 CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 *� Stream flow area = 27.500(Ac.) Runoff from this stream = 51.006(CFS) Time of concentration = 22.56 min. Rainfall intensity = 2.428(In/Hr) Area averaged loss rate (Fm) = 0.3670(In/Hr) Area averaged Pervious ratio (Ap) = 0.5000 Summary of stream data: �r ' Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) �r 1 105.786 16.99 2.878 2 51.006 22.56 2.428 Qmax (1) _ 1.000 * 1.000 * 105.786) + 1.219 * 0.753 * 51.006) + = 152.590 Qmax (2 ) _ 0.822 * 1.000 * 105.786) + 1.000 * 1.000 * 51.006) + = 137.978 Total of 2 streams to confluence: Flow rates before confluence point: 105.786 51.006 Maximum flow rates at confluence using above data: 152.590 137.978 Area of streams before confluence: 43.345 27.500 ' Effective area values after confluence: 64.053 70.845 Results of confluence: ++r Total flow rate = 152.590(CFS) Time of concentration = 16.988 min. �+ Effective stream area after confluence = 64.053(Ac.) Stream Area average Pervious fraction(Ap) = 0.420 Stream Area average soil loss rate(Fm) = 0.354(In/Hr) Study area (this main stream) = 70.85(Ac.) �r ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 31.000 to Point/Station 32.000 A **** PIPEFLOW TRAVEL TIME (User specified size) +�r Upstream point/station elevation = 1056.600(Ft.) Downstream point/station elevation = 1052.000(Ft.) Pipe length = 660.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 152.590(CFS) Given pipe size = 39.00(In.) NOTE: Normal flow is pressure flow in user selected pipe size. The approximate hydraulic grade line above the pipe invert is 25.814(Ft.) at the headworks or inlet of the pipe(s) Pipe friction loss = 22.533(Ft.) Minor friction loss = 7.880(Ft.) K -factor = 1.50 Pipe flow velocity = 18.39(Ft/s) Travel time through pipe = 0.60 min. A Time of concentration (TC) = 17.59 min. rr++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 32.000 to Point/Station 32.000 ** **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 „ Stream flow area = 64.053(Ac.) Runoff from this stream = 152.590(CFS) Time of concentration = 17.59 min. Rainfall intensity = 2.819(In/Hr) W Area averaged loss rate (Fm) = 0.3538(In/Hr) Area averaged Pervious ratio (AP) = 0.4202 +�++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 711.000 to Point/Station 712.000 **** INITIAL AREA EVALUATION **** s RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.367 (In/Hr) Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1069.600(Ft.) Bottom (of initial area) elevation = 1062.100(Ft.) „ Difference in elevation = 7.500(Ft.) Slope = 0.00750 s(%)= 0.75 TC = k(0.389)*[(length"3)/(elevation change)]"0.2 Initial area time of concentration = 16.404 min. Rainfall intensity = 2.939(In/Hr) for a 100.0 year storm +n Effective runoff coefficient used for area (Q=KCIA) is C = 0.788 Subarea runoff = 11.576(CFS) ^� Total initial stream area = 5.000(Ac.) Pervious area fraction = 0.500 Initial area Fm value = 0.367(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 712.000 to Point/Station 713.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1062.100(Ft.) .. End of street segment elevation = 1058.000(Ft.) Length of street segment = 990.000(Ft.) Height of curb above gutter flowline 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) f m crown to crossfall grade break = 40.500(Ft.) Manning s N rom g a Estimated mean flow rate at midpoint of street = 28.940(CFS) Depth of flow = 0.734(Ft.), Average velocity = 2.785(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 3.37(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 31.949(Ft.) Flow velocity = 2.78(Ft/s) Travel time = 5.92 min. TC = 22.33 min. Adding area flow to street M DlstanC= A. Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [11 side (s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 'f rade break to crown = 0.0150 Manning s N rom g a Estimated mean flow rate at midpoint of street = 28.940(CFS) Depth of flow = 0.734(Ft.), Average velocity = 2.785(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 3.37(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 31.949(Ft.) Flow velocity = 2.78(Ft/s) Travel time = 5.92 min. TC = 22.33 min. Adding area flow to street M 131 RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 .. Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 56.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.367(In/Hr) do Rainfall intensity = 2.443(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified �. rational method)(Q=KCIA) is C = 0.765 Subarea runoff = 25.791(CFS) for 15.000(Ac.) Total runoff = 37.367(CFS) Effective area this stream = 20.00(Ac.) Total Study Area (Main Stream No. 1) = 105.00(Ac.) ■ Area averaged Fm value = 0.367(In/Hr) Street flow at end of street = 37.367(CFS) Half street flow at end of street = 37.367(CFS) a Depth of flow = 0.801(Ft.), Average velocity = 2.882(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 6.69(Ft.) Flow width (from curb towards crown)= 35.278(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 713.000 to Point/Station 713.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 20.000(Ac.) Runoff from this stream = 37.367(CFS) Time of concentration = 22.33 min. Rainfall intensity = 2.443(In/Hr) Area averaged loss rate (Fm) = 0.3670(In/Hr) Area averaged Pervious ratio (Ap) = 0.5000 Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) 1 152.590 17.59 2 37.367 22.33 Qmax (1) = 1.000 * 1.181 * Qmax (2 ) _ 0.847 * 1.000 * 2.819 2.443 1.000 * 152.590) + 0.788 * 37.367) + _ 1.000 * 152.590) + 1.000 * 37.367) + _ 187.356 166.672 Total of 2 streams to confluence: Flow rates before confluence point: 152.590 37.367 Maximum flow rates at confluence using above data: 187.356 166.672 Area of streams before confluence: 64.053 20.000 Effective area values after confluence: 79.806 84.053 Results of confluence: Total flow rate = 187.356(CFS) 13i3 -, do Time of concentration = 17.586 min. Effective stream area after confluence = 79.806(Ac.) Stream Area average Pervious fraction(Ap) = 0.439 Stream Area average soil loss rate(Fm) = 0.357(In/Hr) Study area (this main stream) = 84.05(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 32.000 to Point/Station 35.000 .. **** PIPEFLOW TRAVEL TIME (User specified size) **** A Upstream point/station elevation = 1052.000(Ft.) Downstream point/station elevation = 1041.000(Ft.) Pipe length = 1320.00(Ft.) Mannings N = 0.013 ■ No. of pipes = 1 Required pipe flow = 187.356(CFS) Given pipe size = 51.00(In.) * NOTE: Normal flow is pressure flow in user selected pipe size. The approximate hydraulic grade line above the pipe invert is 9.310(Ft.) at the headworks or inlet of the pipe(s) Pipe friction loss = 16.247(Ft.) Minor friction loss = 4.063(Ft.) K -factor = 1.50 Pipe flow velocity = 13.21(Ft/s) Travel time through pipe = 1.67 min. Time of concentration (TC) = 19.25 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ a Process from Point/Station 35.000 to Point/Station 35.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 79.806(Ac.) Runoff from this stream = 187.356(CFS) Time of concentration = 19.25 min. Rainfall intensity = 2.670(In/Hr) Area averaged loss rate (Fm) = 0.3569(In/Hr) �. Area averaged Pervious ratio (Ap) = 0.4392 �r ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 35.000 to Point/Station 35.000 **** USER DEFINED FLOW INFORMATION AT A POINT **** Soil classification AP and SCS values input by user USER INPUT of soil data for subarea SCS curve number for soil(AMC 2) = 40.10 Pervious ratio(Ap) = 0.2270 Max loss rate(Fm)= 0.208(In/Hr) Rainfall intensity = 2.524(In/Hr) for a 100.0 year storm User specified values are as follows: TC = 21.15 min. Rain intensity = 2.52(In/Hr) Total area this stream = 114.22(Ac.) s Total Study Area (Main Stream No. 1) = 219.22(Ac.) Total runoff = 251.95(CFS) +n ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 35.000 to Point/Station 35.000 **** CONFLUENCE OF MINOR STREAMS **** r1 Along Main Stream number: 1 in normal stream number 2 •w ar Stream flow area = 114.220(Ac.) Runoff from this stream = 251.950(CFS) Time of concentration = 21.15 min. Rainfall intensity = 2.524(In/Hr) Area averaged loss rate (Fm) = 0.2079(In/Hr) Area averaged Pervious ratio (Ap) = 0.2270 Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) 1 187.356 19.25 2.670 2 251.950 21.15 2.524 Qmax (1) = 1.000 * 1.000 * 187.356) + 1.063 * 0.910 * 251.950) + = 431.201 Qmax (2 ) = 0.937 * 1.000 * 187.356) + 1.000 * 1.000 * 251.950) + = 427.444 Total of 2 streams to confluence: Flow rates before confluence point: 187.356 251.950 ar Maximum flow rates at confluence using above data: 431.201 427.444 *� Area of streams before confluence: 79.806 114.220 Effective area values after confluence: 183.777 194.026 Results of confluence: Total flow rate = 431.201(CFS) Time of concentration = 19.252 min. " Effective stream area after confluence = 183.777(Ac.) Stream Area average Pervious fraction(Ap) = 0.314 Stream Area average soil loss rate(Fm) = 0.269(In/Hr) Study area (this main stream) = 194.03(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ' Process from Point/Station 35.000 to Point/Station 38.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1041.000(Ft.) Downstream point/station elevation = 1035.000(Ft.) Pipe length = 1320.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 431.201(CFS) Given pipe size = 84.00(In.) Calculated individual pipe flow = 431.201(CFS) Normal flow depth in pipe = 69.00(In.) " Flow top width inside pipe = 64.34(In.) Critical Depth = 65.56(In.) Pipe flow velocity = 12.76(Ft/s) Travel time through pipe = 1.72 min. Time of concentration (TC) = 20.98 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 38.000 to Point/Station 38.000 **** CONFLUENCE OF MINOR STREAMS **** L7 r- f315 d. Along Main Stream number: 1 in normal stream number 1 ., Stream flow area = 183.777(Ac.) Runoff from this stream = 431.201(CFS) " Time of concentration = 20.98 min. Rainfall intensity = 2.536(In/Hr) Area averaged loss rate (Fm) = 0.2692(In/Hr) Area averaged Pervious ratio (Ap) = 0.3143 4= 4W ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 38.000 to Point/Station 38.000 10 **** USER DEFINED FLOW INFORMATION AT A POINT **** di Soil classification AP and SCS values input by user USER INPUT of soil data for subarea SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.3330 Max loss rate(Fm)= 0.326(In/Hr) Rainfall intensity = 2.622(In/Hr) for a 100.0 year storm User specified values are as follows: TC = 19.85 min. Rain intensity = 2.62(In/Hr) Total area this stream = 106.22(Ac.) Total Study Area (Main Stream No. 1) = 325.44(Ac.) Total runoff = 232.43(CFS) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 38.000 to Point/Station 38.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 106.220(Ac.) Runoff from this stream = 232.430(CFS) Time of concentration = 19.85 min. a Rainfall intensity = 2.622(In/Hr) Area averaged loss rate (Fm) = 0.3256(In/Hr) Area averaged Pervious ratio (Ap) = 0.3330 Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) 1 431.201 20.98 2.536 9 2 232.430 19.85 2.622 Qmax (1) _ 1.000 * 1.000 * 431.201) + Qmax (2 ) _ 0.963 * 1.000 * 232.430) + = 654.984 1.038 * 0.946 * 431.201) + 1.000 * 1.000 * 232.430) + = 655.845 Total of 2 streams to confluence: Flow rates before confluence point: 431.201 232.430 Maximum flow rates at confluence using above data: 654.984 655.845 Area of streams before confluence: 'r 183.777 106.220 Effective area values after confluence: 0 .�e 289.997 280.125 Results of confluence: Total flow rate = 655.845(CFS) Time of concentration = 19.850 min. +� Effective stream area after confluence = 280.125(Ac.) Stream Area average Pervious fraction(Ap) = 0.321 Stream Area average soil loss rate(Fm) = 0.290(In/Hr) Study area (this main stream) = 290.00(Ac.) Along Main Stream number: 1 in normal stream number 1 Stream flow area = 280.125(Ac.) Runoff from this stream = 655.845(CFS) Time of concentration = 20.82 min. Rainfall intensity = 2.548(In/Hr) Area averaged loss rate (Fm) = 0.2899(In/Hr) w Area averaged Pervious ratio (Ap) = 0.3211 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ *� Process from Point/Station 817.000 to Point/Station 818.000 **** INITIAL AREA EVALUATION **** RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) �. Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1049.000(Ft.) Bottom (of initial area) elevation = 1044.000(Ft.) Difference in elevation = 5.000(Ft.) ! Slope = 0.00500 s(%)= 0.50 TC = k(0.389)*[(length"3)/(elevation change)1^0.2 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 38.000 to Point/Station 39.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** �r Upstream point/station elevation = 1035.000(Ft.) Downstream point/station elevation = 1026.600(Ft.) + Pipe length = 990.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 655.845(CFS) Given pipe size = 84.00(In.) NOTE: Normal flow is pressure flow in user selected pipe size. The approximate hydraulic grade line above the pipe invert is 8.795(Ft.) at the headworks or inlet of the pipe(s) Pipe friction loss = 10.431(Ft.) " Minor friction loss = 6.765(Ft.) K -factor = 1.50 �c Pipe flow velocity = 17.04(Ft/s) Travel time through pipe = 0.97 min. * Time of concentration (TC) = 20.82 min. rr ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 39.000 to Point/Station 39.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 280.125(Ac.) Runoff from this stream = 655.845(CFS) Time of concentration = 20.82 min. Rainfall intensity = 2.548(In/Hr) Area averaged loss rate (Fm) = 0.2899(In/Hr) w Area averaged Pervious ratio (Ap) = 0.3211 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ *� Process from Point/Station 817.000 to Point/Station 818.000 **** INITIAL AREA EVALUATION **** RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) �. Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1049.000(Ft.) Bottom (of initial area) elevation = 1044.000(Ft.) Difference in elevation = 5.000(Ft.) ! Slope = 0.00500 s(%)= 0.50 TC = k(0.389)*[(length"3)/(elevation change)1^0.2 Initial area time of concentration = 17.789 min. Rainfall intensity = 2.800(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.743 Subarea runoff = 10.399(CFS) Total initial stream area = 5.000(Ac.) Pervious area fraction = 0.500 Initial area Fm value = 0.489(In/Hr) a1 44 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 818.000 to Point/Station 819.000 A **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1044.000(Ft.) End of street segment elevation = 1042.300(Ft.) Length of street segment = 330.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) do Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side (s) of the street Distance from curb to property line = 10.000(Ft.) ' Slope from curb to property line (v/hz) = 0.020 rri Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) •� Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 15.599(CFS) Depth of flow = 0.461(Ft.), Average velocity = 2.284(Ft/s) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 18.285(Ft.) Flow velocity = 2.28(Ft/s) Travel time = 2.41 min. TC = 20.20 min. Adding area flow to street RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 +� SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) *� Rainfall intensity = 2.594(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.730 Subarea runoff = 8.551(CFS) for 5.000(Ac.) Total runoff = 18.950(CFS) Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 335.44(Ac.) Area averaged Fm value = 0.489(In/Hr) Street flow at end of street = 18.950(CFS) Half street flow at end of street = 9.475(CFS) Depth of flow = 0.489(Ft.), Average velocity = 2.397(Ft/s) Flow width (from curb towards crown) = 19.703 (Ft. ) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 819.000 to Point/Station 820.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** NM Top of street segment elevation = 1042.300(Ft.) End of street segment elevation = 1039.000(Ft.) Length of street segment = 660.000(Ft.) .r Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) "M Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 „ Street flow is on [2] side (s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) rr Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 *� Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 28.425(CFS) Depth of flow = 0.548(Ft.), Average velocity = 2.774(Ft/s) Note: depth of flow exceeds top of street crown. Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 20.000(Ft.) Flow velocity = 2.77(Ft/s) Travel time = 3.97 min. TC = 24.16 min. Adding area flow to street RESIDENTIAL(5 - 7 dwl/acre) •• Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 w SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) Rainfall intensity = 2.330(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area, (total area with modified rational method)(Q=KCIA) is C = 0.711 Subarea runoff = 14.188(CFS) for 10.000(Ac.) Total runoff = 33.138(CFS) Effective area this stream = 20.00(Ac.) Total Study Area (Main Stream No. 1) = 345.44(Ac.) Area averaged Fm value = 0.489(In/Hr) Street flow at end of street = 33.138(CFS) dr Half street flow at end of street = 16.569(CFS) Depth of flow = 0.572(Ft.), Average velocity = 2.948(Ft/s) # Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 820.000 to Point/Station 821.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1039.000(Ft.) End of street segment elevation = 1037.000(Ft.) �. Length of street segment = 330.000(Ft.) Height of curb above gutter.flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) # Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side(s) of the street �r i Distance from curb to property line = 13.000(Ft.) 40 Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500 (In. ) +� Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 41.423(CFS) Depth of flow = 0.778(Ft.), Average velocity = 3.441(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 5.56(Ft.) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 34.141(Ft.) ' Flow velocity = 3.44(Ft/s) Travel time = 1.60 min. TC = 25.76 min. Adding area flow to street RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) " Rainfall intensity = 2.242(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.704 Subarea runoff = 14.198 (CFS) for 10.000 (Ac. ) Total runoff = 47.336(CFS) Effective area this stream = 30.00(Ac.) Total Study Area (Main Stream No. 1) = 355.44(Ac.) Area averaged Fm value = 0.489(In/Hr) ++ Street flow at end of street = 47.336(CFS) Half street flow at end of street = 47.336(CFS) Depth of flow = 0.813(Ft.), Average velocity = 3.512(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 7.30(Ft.) Flow width (from curb towards crown)= 35.881(Ft.) ar ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 821.000 to Point/Station 821.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 30.000(Ac.) Runoff from this stream = 47.336(CFS) Time of concentration = 25.76 min. Rainfall intensity = 2.242(In/Hr) Area averaged loss rate (Fm) = 0.4889(In/Hr) Area averaged Pervious ratio (Ap) = 0.5000 Summary of stream data: 48 Stream Flow rate TC Rainfall Intensity 10 No. (CFS) (min) (In/Hr) 1 655.845 20.82 2.548 2 47.336 25.76 2.242- � Qmax(1) _ 1.000 * 1.000 * 655.845) + i ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 39.000 to Point/Station 40.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1026.600(Ft.) Downstream point/station elevation = 1012.800(Ft.) Pipe length = 1720.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 700.769(CFS) Given pipe size = 84.00(In.) NOTE: Normal flow is pressure flow in user selected pipe size. The approximate hydraulic grade line above the pipe invert is 14.613(Ft.) at the headworks or inlet of the pipe(s) Pipe friction loss = 20.690(Ft.) +. Minor friction loss = 7.723(Ft.) K -factor = 1.50 Pipe flow velocity = 18.21(Ft/s) Travel time through pipe = 1.57 min. Time of concentration (TC) = 22.39 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ^* Process from Point/Station 40.000 to Point/Station 40.000 a **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 304.370(Ac.) Runoff from this stream = 700.769(CFS) Time of concentration = 22.39 min. Rainfall intensity = 2.439(In/Hr) Area averaged loss rate (Fm) = 0.3091(In/Hr) Area averaged Pervious ratio (Ap) = 0.3384 �r ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 822.000 to Point/Station 823.000 **** INITIAL AREA EVALUATION **** RESIDENTIAL(5 - 7 dwl/acre) 1.174 * 0.808 * 47.336) + = 700.769 Qmax (2 ) _ 0.865 * 1.000 * 655.845) + 1.000 * 1.000 * 47.336) + = 614.395 rr Total of 2 streams to confluence: Flow rates before confluence point: 655.845 47.336 Maximum flow rates at confluence using above data: 700.769 614.395 Area of streams before confluence: 280.125 30.000 Effective area values after confluence: ' 304.370 310.125 +� Results of confluence: Total flow rate = 700.769(CFS) # Time of concentration = 20.818 min. Effective stream area after confluence = 304.370(Ac.) Stream Area average Pervious fraction(Ap) = 0.338 Stream Area average soil loss rate(Fm) = 0.309(In/Hr) Study area (this main stream) = 310.13(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 39.000 to Point/Station 40.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1026.600(Ft.) Downstream point/station elevation = 1012.800(Ft.) Pipe length = 1720.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 700.769(CFS) Given pipe size = 84.00(In.) NOTE: Normal flow is pressure flow in user selected pipe size. The approximate hydraulic grade line above the pipe invert is 14.613(Ft.) at the headworks or inlet of the pipe(s) Pipe friction loss = 20.690(Ft.) +. Minor friction loss = 7.723(Ft.) K -factor = 1.50 Pipe flow velocity = 18.21(Ft/s) Travel time through pipe = 1.57 min. Time of concentration (TC) = 22.39 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ^* Process from Point/Station 40.000 to Point/Station 40.000 a **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 304.370(Ac.) Runoff from this stream = 700.769(CFS) Time of concentration = 22.39 min. Rainfall intensity = 2.439(In/Hr) Area averaged loss rate (Fm) = 0.3091(In/Hr) Area averaged Pervious ratio (Ap) = 0.3384 �r ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 822.000 to Point/Station 823.000 **** INITIAL AREA EVALUATION **** RESIDENTIAL(5 - 7 dwl/acre) 1521 Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 ++� SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(AP) = 0.5000 Max loss rate (Fm) = 0 .489 (In/Hr) Initial subarea data: Initial area flow distance = 1000.000(Ft.) Top (of initial area) elevation = 1037.700(Ft.) �. Bottom (of initial area) elevation = 1034.300(Ft.) Difference in elevation = 3.400(Ft.) Slope = 0.00340 s(%)= 0.34 TC = k(0.389)*[(length-3)/(elevation change)]^0.2 Initial area time of concentration = 19.216 min. Rainfall intensity = 2.673(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.735 '* Subarea runoff = 9.829(CFS) Total initial stream area = 5.000(Ac.) Pervious area fraction = 0.500 Initial area Fm value = 0 .489 (In/Hr) r�r ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ " Process from Point/Station 823.000 to Point/Station 824.000 al **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1034.300(Ft.) End of street segment elevation = 1032.000(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.481(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 19.288(Ft.) Flow velocity = 1.94(Ft/s) - 5 66 min TC = 24.87 min. 14.744(CFS) 1.944(Ft/S) Travel time = - Adding area flow to street RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) Rainfall intensity = 2.290(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.708 Subarea runoff = 6.378(CFS) for 5.000(Ac.) w i3 z Total runoff = 16.208(CFS) Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 365.44(Ac.) Area averaged Fm value = 0.489(In/Hr) air Street flow at end of street = 16.208(CFS) Half street flow at end of street = 8.104(CFS) +* Depth of flow = 0.495(Ft.), Average velocity = 1.990(Ft/s) Note: depth of flow exceeds top of street crown. Flow width (from curb towards crown)= 20.000(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 824.000 to Point/Station 825.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** ar Top of street segment elevation = 1032.000(Ft.) End of street segment elevation = 1027.000(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street ,r Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 �. Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500( -In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 24.311(CFS) Depth of flow = 0.619(Ft.), Average velocity = 3.501(Ft/s) # Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 26.217(Ft.) Flow velocity = 3.50(Ft/s) Travel time = 3.14 min. TC = 28.02 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 ar Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342(In/Hr) Rainfall intensity = 2.132(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.725 Subarea runoff = 14.688(CFS) for 10.000(Ac.) Total runoff = 30.896(CFS) Effective area this stream = 20.00(Ac.) Total Study Area (Main Stream No. 1) = 375.44(Ac.) Area averaged Fm value = 0.416(In/Hr) .. Street flow at end of street = 30.896(CFS) Half street flow at end of street = 30.896(CFS) Depth of flow = 0.670(Ft.), Average velocity = 3.706(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 0.17(Ft.) Flow width (from curb towards crown)= 28.751(Ft.) r s ■ ,. ar 40 do ■ do .. .o .. 40 �r ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 825.000 to Point/Station 826.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1027.000(Ft.) End of street segment elevation = 1023.000(Ft.) Length of street segment = 750.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 42.000(Ft.) Distance from crown to crossfall grade break = 40.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street Distance from curb to property line = 13.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.755(Ft.), Average velocity = Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 32.977(Ft.) Flow velocity = 3.19(Ft/s) Travel time = 3.92 min. TC = 31.93 min. Adding area flow to street CONDOMINIUM subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 35.530(CFS) 3.190(Ft/s) 4.39 (Ft.) Pervious ratio(Ap) = 0.3500 Max loss rate(Fm)= 0.342(In/Hr) Rainfall intensity = 1.971(In/Hr) for a 100.0 year storm Effective runoff coefficient used for arda,(total area with modified rational method)(Q=KCIA) is C = 0.718 " Subarea runoff = 5.896(CFS) for 6.000(Ac.) Total runoff = 36.792(CFS) Effective area this stream = 26.00(Ac.) �+ Total Study Area (Main Stream No. 1) = 381.44(Ac.) Area averaged Fm value = 0.399(In/Hr) Street flow at end of street = 36.792(CFS) Half street flow at end of street = 36.792(CFS) Depth of flow = 0.764(Ft.), Average velocity = 3.204(Ft/s) Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = 4.85(Ft.) Flow width (from curb towards crown)= 33.431(Ft.) �.++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 826.000 to Point/Station 826.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 26.000(Ac.) Runoff from this stream = 36.792(CFS) 132{ Time of concentration = 31.93 min. " Rainfall intensity = 1.971(In/Hr) Area averaged loss rate (Fm) = 0.3986(In/Hr) Area averaged Pervious ratio (Ap) = 0.4077 ri Summary of stream data: Total of 2 streams to confluence: Flow rates before confluence point: 700.769 36.792 Maximum flow rates at confluence using above data: 734.244 583.631 Area of streams before confluence: 304.370 26.000 .. Effective area values after confluence: 322.601 330.370 Results of confluence: Total flow rate = 734.244(CFS) Time of concentration = 22.393 min. +• Effective stream area after confluence = 322.601(Ac.) Stream Area average Pervious fraction(Ap) = 0.344 Stream Area average soil loss rate(Fm) = 0.316(In/Hr) Study area (this main stream) = 330.37(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 40.000 to Point/Station 94.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1011.300(Ft.) Downstream point/station elevation = 1004.000(Ft.) w Pipe length = 900.00(Ft.) Mannings N = 0.013 No. of pipes = 1 Required pipe flow = 734.244(CFS) Given pipe size = 102.00(In.) Calculated individual pipe flow = 734.244(CFS) Normal flow depth in pipe = 66.56(In.) Flow top width inside pipe = 97.14(In.) Critical Depth = 81.36(In.) " Pipe flow velocity = 18.73(Ft/s) Travel time through pipe = 0.80 min. Time of concentration (TC) = 23.19 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 94.000 to Point/Station 94.000 CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) w 1 700.769 22.39 2.439 2 36.792 31.93 1.971 Qmax(1) _ 1.000 * 1.000 * 700.769) + 1.298 * 0.701 * 36.792) + = 734.244 Qmax (2 ) _ 0.780 * 1.000 * 700.769) + 1.000 * 1.000 * 36.792) + = 583.631 Total of 2 streams to confluence: Flow rates before confluence point: 700.769 36.792 Maximum flow rates at confluence using above data: 734.244 583.631 Area of streams before confluence: 304.370 26.000 .. Effective area values after confluence: 322.601 330.370 Results of confluence: Total flow rate = 734.244(CFS) Time of concentration = 22.393 min. +• Effective stream area after confluence = 322.601(Ac.) Stream Area average Pervious fraction(Ap) = 0.344 Stream Area average soil loss rate(Fm) = 0.316(In/Hr) Study area (this main stream) = 330.37(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 40.000 to Point/Station 94.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** Upstream point/station elevation = 1011.300(Ft.) Downstream point/station elevation = 1004.000(Ft.) w Pipe length = 900.00(Ft.) Mannings N = 0.013 No. of pipes = 1 Required pipe flow = 734.244(CFS) Given pipe size = 102.00(In.) Calculated individual pipe flow = 734.244(CFS) Normal flow depth in pipe = 66.56(In.) Flow top width inside pipe = 97.14(In.) Critical Depth = 81.36(In.) " Pipe flow velocity = 18.73(Ft/s) Travel time through pipe = 0.80 min. Time of concentration (TC) = 23.19 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 94.000 to Point/Station 94.000 CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 322.601(Ac.) Runoff from this stream = 734.244(CFS) Time of concentration = 23.19 min. " Rainfall intensity = 2.388(In/Hr) Area averaged loss rate (Fm) = 0.3162(In/Hr) Area averaged Pervious ratio (Ap) = 0.3439 rr ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 827.000 to Point/Station 828.000 **** INITIAL AREA EVALUATION **** ar RESIDENTIAL(5 - 7 dwl/acre) Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 . Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.5000 Max loss rate(Fm)= 0.489(In/Hr) Initial subarea data: Initial area flow distance = 900.000(Ft.) Top (of initial area) elevation = 1023.000(Ft.) Bottom (of initial area) elevation = 1014.000(Ft.) Difference in elevation = 9.000(Ft.) Slope = 0.01000 s(%)= 1.00 TC = k(0.389)*[(length"3)/(elevation change)1^0.2 .e Initial area time of concentration = 14.847 min. Rainfall intensity = 3.121(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.759 Subarea runoff = 14.211(CFS) ' Total initial stream area = 6.000(Ac.) +�r Pervious area fraction = 0.500 Initial area Fm value = 0.489(In/Hr) tr ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 828.000 to Point/Station 828.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 6.000(Ac.) Runoff from this stream = 14.211(CFS) Time of concentration = 14.85 min. Rainfall intensity = 3.121(In/Hr) Area averaged loss rate (Fm) = 0.4889(In/Hr) Area averaged Pervious ratio (Ap) = 0.5000 Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) a ■ 1 734.244 23.19 2.388 .., 2 14.211 14.85 3.121 Qmax (1) _ 1.000 * 1.000 * 734.244) + 0.722 * 1.000 * 14.211) + = 744.498 Qmax(2) _ 1.354 * 0.640 * 734.244) + 1.000 * 1.000 * 14.211) + = 650.483 L- "' Total of 2 streams to confluence: Flow rates before confluence point: 734.244 14.211 Maximum flow rates at confluence using above data: 744.498 650.483 Area of streams before confluence: 322.601 6.000 Effective area values after confluence: 328.601 212.512 Results of confluence: Total flow rate = 744.498(CFS) Time of concentration = 23.194 min. Effective stream area after confluence = 328.601(Ac.) Stream Area average Pervious fraction(Ap) = 0.347 Stream Area average soil loss rate(Fm) = 0.319(In/Hr) .� Study area (this main stream) = 328.60(Ac.) ++++++++++++.++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 94.000 to Point/Station 94.000 +� **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 40 Stream flow area = 328.601(Ac.) Runoff from this stream = 744.498(CFS) Time of concentration = 23.19 min. Rainfall intensity = 2.388(In/Hr) Area averaged loss rate (Fm) = 0.3193(In/Hr) Area averaged Pervious ratio (Ap) = 0.3467 End of computations, Total Study Area = 387.44 (Ac.) �r The following figures may be used for a unit hydrograph study of the same area. Note: These figures do not consider reduced effective area effects caused by confluences in the rational equation. Area averaged pervious area fraction(Ap) = 0.348 Area averaged SCS curve number = 37.8 AN do 4" A I" do 49 0 /NL Z)z SN REVISED 13 51 No 49 San Bernardino County Rational Hydrology Program (Hydrology Manual Date - August 1986) CIVILCADD/CIVILDESIGN Engineering Software, (c) 1989-2001 Version 6.4 Rational Hydrology Study Date: 09/02/04 ------------------------------------------------------------------------ FONTANA / TR 16678 LINE DZ -5 HYDROLOGY (REVISED) �. 100 YEAR STORM JN 05086 CALLED BY : HERMAN HOVAGIMYAN ------------------------------------------------------------------------ Hall & Forman, Inc. - SIN 950 ------------------------------------------------------------------------ ********* Hydrology Study Control Information ********** ,rr ------------------------------------------------------------------------ Rational hydrology study storm event year is 100.0 10 Year storm 1 hour rainfall = 0.930(In.) 100 Year storm 1 hour rainfall = 1.350 (In. ) Computed rainfall intensity: Storm year = 100.00 1 hour rainfall = 1.350 (In.) Slope used for rainfall intensity curve b = 0.6000 rr Soil antecedent moisture condition (AMC) = 2 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ wr Process from Point/Station 718.000 to Point/Station 719.000 **** INITIAL AREA EVALUATION **** ' COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Initial subarea data: Initial area flow distance = 990.000(Ft.) Top (of initial area) elevation = 1085.000(Ft.) �r Bottom (of initial area) elevation = 1075.000(Ft.) Difference in elevation = 10.000(Ft.) Slope = 0.01010 s(%-)= 1.01 4 TC = k(0.304)*[(length"3)/(elevation change)] -0.2 Initial area time of concentration = 12.030 min. Rainfall intensity = 3.541(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.875 Subarea runoff = 15.492(CFS) Total initial stream area = 5.000(Ac.) Pervious area fraction = 0.100 Initial area Fm value = 0.098(In/Hr) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 719.000 to Point/Station 709.100 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** 49 Top of street segment elevation = 1075.000(Ft.) End of street segment elevation = 1068.000(Ft.) Length of street segment = 660.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 32.000(Ft.) Distance from crown to crossfall grade break = 30.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street Distance from curb to property line = 14.000(Ft.) Slope from curb to property line (v/hz) = 0.020 ,A Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 23.239(CFS) Depth of flow = 0.579(Ft.), Average velocity = 3.928(Ft/s) * Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 24.176(Ft.) Flow velocity = 3.93(Ft/s) Travel time = 2.80 min. TC = 14.83 min. Adding area flow to street COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 am Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 dN Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(Iri/Hr) Rainfall intensity = 3.123(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.872 Subarea runoff = 11.732(CFS) for 5.000(Ac.) Total runoff = 27.225(CFS) Effective area this stream = 10.00(Ac.) Total Study Area (Main Stream No. 1) = 10.00(Ac.) Area averaged Fm value = 0.098(In/Hr) a Street flow at end of street = 27.225(CFS) Half street flow at end of street = 27.225(CFS) Depth of flow = 0.609(Ft.), Average velocity = 4.086(Ft/s) Flow width (from curb towards crown)= 25.675(Ft.) rr ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 709.100 to Point/Station 710.100 ■ **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1068.000(Ft.) End of street segment elevation = 1064.000(Ft.) A Length of street segment = 650.000(Ft.) Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 32.000(Ft.) Distance from crown to crossfall grade break = 30.500(Ft.) Slope from gutter to grade bzeak (v/hz) = 0.020 �. Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street Distance from curb to property line = 14.000(Ft.) Slope from curb to property line (v/hz) 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 1.500(In.)- Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.674(Ft.), Average velocity = Warning: depth of flow exceeds top of curb Distance that curb overflow reaches into property = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 28.952(Ft.) Flow velocity = 3.34(Ft/s) Travel time = 3.24 min. TC = 18.07 min. Adding area flow to street COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= The area added to the existing stream causes a a lower flow rate of Q = 25.886(CFS) 1353 28.246(CFS) 3.341(Ft/s) therefore the upstream flow rate of Q = 27.225(CFS) Rainfall intensity = 2.773(In/Hr) for a 100.0 ye Effective runoff coefficient used for area,(total area rational method)(Q=KCIA) is C = 0.868 Subarea runoff = 0.000(CFS) for 0.750(Ac.) Total runoff = 27.225(CFS) Effective area this stream = 10.75(Ac.) Total Study Area (Main Stream No. 1) = 10.75(Ac.) 0.37(Ft.) 0.098(In/Hr) is being used ar storm with modified is Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 27.225(CFS) Half street flow at end of street = 27.225(CFS) Depth of flow = 0.664(Ft.), Average velocity = 3.330(Ft/s) Flow width (from curb towards crown)= 28.467(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ .� Process from Point/Station 710.100 to Point/Station 713.100 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1064.000(Ft.) End of street segment elevation = 1058.300(Ft.) Length of street segment = 580.000(Ft.) Height of curb above gutter flowline = 8.0(In.) '* Width of half street (curb to crown) = 32.000(Ft.) Distance from crown to crossfall grade break = 30.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on (1] side (s) of the street Distance from curb to property line = 14.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) A Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 28.048(CFS) Depth of flow = 0.622(Ft.), Average velocity = 4.000(Ft/s) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 26.346(Ft.) Flow velocity = 4.00(Ft/s) i Travel time = 2.42 min. TC = 20.49 min. Adding area flow to street COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 '* Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) The area added to the existing stream causes a a lower flow rate of Q = 25.388(CFS) therefore the upstream flow rate of Q = 27.225(CFS) is being used Rainfall intensity = 2.572(In/Hr) for a 100.0 year storm ' Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.866 Subarea runoff = 0.000 (CFS) for 0.650 (Ac. ) "* Total runoff = 27.225(CFS) Effective area this stream = 11.40(Ac.) Total Study Area (Main Stream No. 1) = 11.40(Ac.) Area averaged Fm value = 0.098(In/Hr) Street flow at end of street = 27.225(CFS) Half street flow at end of street = 27.225(CFS) Depth of flow = 0.616(Ft.), Average velocity = 3.970(Ft/s) Flow width (from curb towards crown)= 26.049(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 713.100 to Point/Station 713.100 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Stream flow area = 11.400(Ac.) Runoff from this stream = 27.225(CFS) Time of concentration = 20.49 min. Rainfall intensity = 2.572(In/Hr) Area averaged loss rate (Fm) = 0.0978(In/Hr) Area averaged Pervious ratio (Ap) = 0.1000 a ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ '" Process from Point/Station 32.000 to Point/Station 32.000 4d **** USER DEFINED FLOW INFORMATION AT A POINT **** *A Soil classification AP and SCS values input by user A USER INPUT of soil data for subarea SCS curve number for soil(AMC 2) = 49.69 w Pervious ratio(Ap) = 0.4390 Max loss rate(Fm)= 0.357(In/Hr) Rainfall intensity = 2.819(In/Hr) for a 100.0 year storm W User specified values are as follows: TC = 17.59 min. Rain intensity = 2.82(In/Hr) Total area this stream = 15.00(Ac.) Total Study Area (Main Stream No. 1) = 26.40(Ac.) Total runoff = 187.36(CFS) +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 32.000 to Point/Station 32.000 CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 13ry5 Stream flow area = 15.000(Ac.) Runoff from this stream = 187.360(CFS) Time of concentration = 17.59 min. .. Rainfall intensity = 2.819 (In/Hr) •+ Area averaged loss rate (Fm) = 0.3570(In/Hr) Area averaged Pervious ratio (Ap) = 0.4390 Summary of stream data: Stream Flow rate No. (CFS) 1 27.225 2 187.360 Qmax (1) _ 1.000 * 0.900 * Qmax (2 ) _ 1.100 * 1.000 * TC (min) 20.49 17.59 Rainfall Intensity (In/Hr) 2.572 2.819 1.000 * 27.225) + 1.000 * 187.360) + _ 0.858 * 27.225) + 1.000 * 187.360) + _ 195.816 213.061 Total of 2 streams to confluence: Flow rates before confluence point: 27.225 187.360 Maximum flow rates at confluence using above data: 195.816 213.061 Area of streams before confluence: 11.400 15.000 Effective area values after confluence: 26.400 24.787 Results of confluence: Total flow rate = 213.061(CFS) Time of concentration = 17.590 min. Effective stream area after confluence = 24.787(Ac.) Stream Area average Pervious fraction(Ap) = 0.293 Stream Area average soil loss rate(Fm) = 0.245(In/Hr) Study area (this main stream) = 26.40(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 32.000 to Point/Station 35.000 **** PIPEFLOW TRAVEL TIME (Program estimated size) **** Upstream point/station elevation = 1050.000(Ft.) A Downstream point/station elevation = 1040.650(Ft.) Pipe length = 1320.00(Ft.) Manning's N = 0.013 No. of pipes = 1 Required pipe flow = 213.061(CFS) Nearest computed pipe diameter = 60.00(In.) Calculated individual pipe flow = 213.061(CFS) Normal flow depth in pipe = 47.72(In.) Flow top width inside pipe = 48.42(In.) Critical Depth = 49.83(In.) Pipe flow velocity = 12.72(Ft/s) •. Travel time through pipe = 1.73 min. �r Time of concentration (TC) = 19.32 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ AN Process from Point/Station 35.000 to Point/Station 35.000 **** CONFLUENCE OF MINOR STREAMS **** 4. 6 135 'o Along Main Stream number: 1 in normal stream number 1 Stream flow area = 24.787(Ac.) Runoff from this stream = 213.061(CFS) +r Time of concentration = 19.32 min. Rainfall intensity = 2.665(In/Hr) Area averaged loss rate (Fm) = 0.2451(In/Hr) Area averaged Pervious ratio (Ap) = 0.2926 .■ ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 35.000 to Point/Station 35.000 **** USER DEFINED FLOW INFORMATION AT A POINT **** A a" w. .r ar Soil classification AP and SCS values input by user USER INPUT of soil data for subarea SCS curve number for soil(AMC 2) = 31.90 Pervious ratio(Ap) = 0.3390 Max loss rate(Fm)= 0.332(In/Hr) Rainfall intensity = 3.378(In/Hr) for a 100.0 year storm User specified values are as follows: TC = 13.01 min. Rain intensity = 3.38(In/Hr) Total area this stream = 113.10(Ac.) Total Study Area (Main Stream No. 1) = 139.50(Ac.) Total runoff = 220.66(CFS) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 35.000 to Point/Station 35.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 +� Stream flow area = 113.100(Ac.) Runoff from this stream = 220.660(CFS) "* Time of concentration = 13.01 min. Rainfall intensity = 3.378 (In/Hr) Area averaged loss rate (Fm) = 0.3317(In/Hr) Area averaged Pervious ratio (Ap) = 0.3390 A Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) 1 213.061 19.32 2.665 2 220.660 13.01 3.378 Qmax (1) _ 1.000 * 1.000 * 213.061) + 0.766 * 1.000 * 220.660) + = 382.045 Qmax (2 ) _ 1.295 * 0.673 * 213.061) + " 1.000 * 1.000 * 220.660) + = 406.445 Total of 2 streams to confluence: �. Flow rates before confluence point: 213.061 220.660 Maximum flow rates at confluence using above data: 382.045 406.445 Area of streams before confluence: 24.787 113.100 Effective area values after confluence: .. 137.887 129.792 q" Results of confluence: Total flow rate = 406.445(CFS) Time of concentration = 13.010 min. ■. Effective stream area after confluence = 129.792(Ac.) Stream Area average Pervious fraction(Ap) = 0.331 # Stream Area average soil loss rate(Fm) = 0.316(In/Hr) Study area (this main stream) = 137.89(Ac.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ A Process from Point/Station 731.000 to Point/Station 732.000 **** INITIAL AREA EVALUATION **** ,rel COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Initial subarea data: Initial area flow distance = 725.000(Ft.) Top (of initial area) elevation = 1058.000(Ft.) Bottom (of initial area) elevation = 1053.200(Ft.) Difference in elevation = 4.800(Ft.) Slope = 0.00662 s(%)= 0.66 TC = k(0.304)*[(length"3)/(elevation change)1^0.2 'r Initial area time of concentration = 11.557 min. Rainfall intensity = 3.627(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.876 �r Subarea runoff = 3.176(CFS) Total initial stream area = 1.000(Ac.) Pervious area fraction = 0.100 Initial area Fm value = 0.098(In/Hr) 10 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 732.000 to Point/Station 733.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 1053.200(Ft.) End of street segment elevation = 1048.800(Ft.) aw Length of street segment = 5.950(Ft.) a Height of curb above gutter flowline = 8.0(In.) Width of half street (curb to crown) = 32.000(Ft.) Distance from crown to crossfall grade break = 30.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [1] side (s) of the street Distance from curb to property line = 14.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) a. Gutter hike from flowline = 1.500(In.) Manning's N in gutter = 0.0150 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 4.447(CFS) Depth of flow = 0.197(Ft.), Average velocity = 13.415(Ft/s) Streetflow hydraulics at midpoint of street travel: Fm � 358 Halfstreet flow width = 5.101(Ft.) Flow velocity = 13.42(Ft/s) Travel time = 0.01 min. TC = 11.56 min. Adding area flow to street " COMMERCIAL subarea type Decimal fraction soil group A = 1.000 Decimal fraction soil group B = 0.000 ., Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 *• SCS curve number for soil(AMC 2) = 32.00 Pervious ratio(AP) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Rainfall intensity = 3.625(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.876 .. Subarea runoff = 2.539(CFS) for 0.800(Ac.) Total runoff = 5.715(CFS) Effective area this stream = 1.80(Ac.) „r Total Study Area (Main Stream No. 1) = 141.30(Ac.) Area averaged Fm value = 0.098(In/Hr) ,. Street flow at end of street = 5.715(CFS) Half street flow at end of street = 5.715(CFS) Depth of flow = 0.210(Ft.), Average velocity = 14.128(Ft/s) Flow width (from curb towards crown)= 5.773(Ft.) End of computations, Total Study Area = 141.30 (Ac.) The following figures may be used for a unit hydrograph study of the same area. Note: These figures do not consider reduced effective area effects caused by confluences in the rational equation. Area averaged pervious area fraction(Ap) = 0.327 Area averaged SCS curve number = 33.8 DECLEZ CHANIVEL MR 40 .■ Ad ..... � .. �._...�.�.� 14-o1 �. San Bernardino County Rational Hydrology Program (Hydrology Manual Date - August 1986) CIVILCADD/CIVILDESIGN Engineering Software, (c) 1989-2001 Version 6.4 Rational Hydrology Study Date: 07/22/04 �r ------------------------------------------------------------------------ FONTANA / DECLEZ CHANNEL HYDROLOGY W/DET. AT SIERRA MIN 100 YEAR STORM 42 JN 04339 ■ Hall & Forman, Inc. - SIN 950 " -------- ---------------------------------------------------------------- ********* Hydrology Study Control Information ********** �r ------------------------------------------------------------------------ Rational hydrology study storm event year is 100.0 A 10 Year storm 1 hour rainfall = 0.930(In.) 41 100 Year storm 1 hour rainfall = 1.350(In.) Computed rainfall intensity: In Storm year = 100.00 1 hour rainfall = 1.350 (In.) Slope used for rainfall intensity curve b = 0.6000 Soil antecedent moisture condition (AMC) = 3 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 93.000 to Point/Station 93.000 **** USER DEFINED FLOW INFORMATION AT A POINT **** ' Soil classification AP and SCS values input by user USER INPUT of soil data for subarea SCS curve number for soil(AMC 2) = 91.60 ■ Adjusted SCS curve number for AMC 3 = 98.32 Pervious ratio(Ap) = 0.7510 Max loss rate(Fm)= 0.025(In/Hr) Rainfall intensity = 2.892(In/Hr) for a 100.0 year storm User specified values are as follows: TC = 16.85 min. Rain intensity = 2.89(In/Hr) , Total area this stream = 804.55(Ac.) Total Study Area (Main Stream No. 1) = 804.55(Ac.) Total runoff = 2064.31(CFS) d++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 93.000 to Point/Station 94.000 ■ **** IMPROVED CHANNEL TRAVEL TIME **** Upstream point elevation = 1005.500(Ft.) Downstream point elevation = 1004.000(Ft.) Channel length thru subarea = 500.000(Ft.) Channel base width = 24.000(Ft.) Slope or 'Z' of left channel bank = 0.000 Slope or 'Z' of right channel bank = 0.000 Manning's 'N' = 0.014 Maximum depth of channel = 9.000(Ft.) Flow(q) thru subarea = 2064.310(CFS) Depth of flow = 5.911(Ft.), Average velocity = 14.552 (Ft/s) Channel flow top width = 24.000(Ft.) Flow Velocity = 14.55(Ft/s) ., I Ao"2 Al Travel time = 0.57 min. Time of concentration = 17.42 min. on Critical depth = 6.125(Ft.) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 94.000 to Point/Station 94.000 �I **** CONFLUENCE OF MINOR STREAMS **** * Along Main Stream number: 1 in normal stream number 1 Stream flow area = 804.550(Ac.) Runoff from this stream = 2064.310(CFS) Time of concentration = 17.42 min. Rainfall intensity = 2.835(In/Hr) Area averaged loss rate (Fm) = 0.0251(In/Hr) Area averaged Pervious ratio (Ap) = 0.7510 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 94.000 to Point/Station 94.000 41 **** USER DEFINED FLOW INFORMATION AT A POINT **** Soil classification AP and SCS values input by user USER INPUT of soil data for subarea SCS curve number for soil(AMC 2) = 37.80 Adjusted SCS curve number for AMC 3 = 57.80 Pervious ratio(Ap) = 0.3480 Max loss rate(Fm)= 0.247(In/Hr) Rainfall intensity = 2.395(In/Hr) for a 100.0 year storm User specified values are as follows: TC = 23.07 min. Rain intensity = 2.40(In/Hr) Total area this stream = 330.49(Ac.) Total Study Area (Main Stream No. 1) = 1135.04(Ac.) Total runoff = 768.00(CFS) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ * Process from Point/Station 94.000 to Point/Station 94.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 330.490(Ac.) Runoff from this stream = 768.000(CFS) Time of concentration = 23.07 min. Rainfall intensity = 2.395(In/Hr) Area averaged loss rate (Fm) = 0.2470(In/Hr) Area averaged Pervious ratio (Ap) = 0.3480 Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) 1 2064.310 17.42 2.835 2 768.000 23.07 2.395 Qmax (1) = 1.000 * 1.000 * 2064.310) + 1.205 * 0.755 * 768.000) + = 2762.964 A Qmax (2 ) _ 0.844 * 1.000 * 2064.310) + 1.000 * 1.000 * 768.000) + = 2509.420 Total of 2 streams to confluence: Flow rates before confluence point: 2064.310 768.000 Maximum flow rates at confluence using above data: 2762.964 2509.420 Area of streams before confluence: ■ 804.550 330.490 Effective area values after confluence: 1054.139 1135.040 Results of confluence: Total flow rate = 2762.964(CFS) „ Time of concentration = 17.423 min. Effective stream area after confluence = 1054.139(Ac.) Stream Area average Pervious fraction(Ap) = 0.634 Stream Area average soil loss rate(Fm) = 0.090(In/Hr) Study area (this main stream) = 1135.04(Ac.) End of computations, Total Study Area = 1135.04 (Ac.) The following figures may be used for a unit hydrograph study of the same area. Note: These figures do not consider reduced effective area effects caused by confluences in the rational equation. Area averaged pervious area fraction(Ap) = 0.634 Area averaged SCS curve number = 75.9 '0 an jW 0 0 y M E M E e E DECLEZ CHANIVEL RE V15ED 14-S Will San Bernardino County Rational Hydrology Program (Hydrology Manual Date - August 1986) .r CIVILCADD/CIVILDESIGN Engineering Software, (c) 1989-2001 Version 6.4 Rational Hydrology Study Date: 09/23/04 ------------------------------------------------------------------------ FONTANA / DECLEZ CHANNEL HYDROLOGY W/DET. AT SIERRA (REVISED) a+• 100 YEAR STORM JN 05086 Hall & Forman, Inc. - SIN 950 • ------------------------------------------------------------------------ ********* Hydrology Study Control Information ********** ,r ------------------------------------------------------------------------ Rational hydrology study storm event year is 100.0 �. 10 Year storm 1 hour rainfall = 0.930(In.) 100 Year storm 1 hour rainfall = 1.350(In.) Computed rainfall intensity: Storm year = 100.00 1 hour rainfall = 1.350 (In.) Slope used for rainfall intensity curve b = 0.6000 �r Soil antecedent moisture condition (AMC) = 3 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 93.000 to Point/Station 93.000 **** USER DEFINED FLOW INFORMATION AT A POINT **** Soil classification AP and SCS values input by user USER INPUT of soil data for subarea SCS curve number for soil(AMC 2) = 91.60 Adjusted SCS curve number for AMC 3 = 98.32 Pervious ratio(Ap) = 0.7510 Max loss rate(Fm)= 0.025(In/Hr) Rainfall intensity = 2.892(In/Hr) for a 100.0 year storm User specified values are as follows: TC = 16.85 min. Rain intensity = 2.89(In/Hr) Total area this stream = 804.55(Ac.) Total Study Area (Main Stream No. 1) = 804.55(Ac.) Total runoff = 2064.31(CFS) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 93.000 to Point/Station 94.000 **** IMPROVED CHANNEL TRAVEL TIME **** Upstream point elevation = 1005.500(Ft.) Downstream point elevation = 1004.000(Ft.) Channel length thru subarea = 500.000(Ft.) Channel base width = 24.000(Ft.) Slope or 'Z' of left channel bank = 0.000 Slope or 'Z' of right channel bank = 0.000 Manning's 'N' = 0.014 Maximum depth of channel = 9.000(Ft.) Flow(q) thru subarea = 2064.310(CFS) Depth of flow = 5.911(Ft.), Average velocity = Channel flow top width = 24.000(Ft.) Flow Velocity = 14.55(Ft/s) 14.552(Ft/s) Total of 2 streams to confluence: Flow rates before confluence point: 2064.310 707.340 Maximum flow rates at confluence using above data: 2755.934 2689.583 Area of streams before confluence: ,. 804.550 330.490 Effective area values after confluence: 1113.622 1135.040 do Results of confluence: Total flow rate = 2755.934(CFS) Time of concentration = 17.423 min. Effective stream area after confluence = 1113.622(Ac.) Stream Area average Pervious fraction(Ap) = 0.633 Stream Area average soil loss rate(Fm) = 0.096(In/Hr) Study area (this main stream) = 1135.04(Ac.) End of computations, Total Study Area = 1135.04 (Ac.) The following figures may . be used for a unit hydrograph study of the same area. Note: These figures do not consider reduced effective area effects caused by confluences in the rational equation. Area averaged pervious area fraction(Ap) = 0.633 +� Area averaged SCS curve number = 74.4 e air F E E M �4s3 Travel time = 0.57 min. Time of concentration = 17.42 min. Critical depth = 6.125(Ft.) r ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 94.000 to Point/Station 94.000 ., **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 A Stream flow area = 804.550(Ac.) Runoff from this stream = 2064.310(CFS) * Time of concentration = 17.42 min. Rainfall intensity = 2.835(In/Hr) +� Area averaged loss rate (Fm) = 0.0251(In/Hr) Area averaged Pervious ratio (Ap) = 0.7510 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 94.000 to Point/Station 94.000 **** USER DEFINED FLOW INFORMATION AT A POINT **** Soil classification AP and SCS values input by user USER INPUT of soil data for subarea SCS curve number for soil(AMC 2) = 32.50 Adjusted SCS curve number for AMC 3 = 52.50 '* Pervious ratio(Ap) = 0.3470 Max loss rate(Fm)= 0.270(In/Hr) Rainfall intensity = 2.723(In/Hr) for a 100.0 year storm User specified values are as follows: TC = 18.63 min. Rain intensity = 2.72(In/Hr) Total area this stream = 330.49(Ac.) Total Study Area (Main Stream No. 1) = 1135.04(Ac.) Total runoff = 707.34 (CFS) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ • Process from Point/Station 94.000 to Point/Station 94.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 2 Stream flow area = 330.490(Ac.) Runoff from this stream = 707.340(CFS) Time of concentration = 18.63 min. Rainfall intensity = 2.723(In/Hr) Area averaged loss rate (Fm) = 0.2703(In/Hr) Area averaged Pervious ratio (Ap) = 0.3470 •� Summary of stream data: Stream Flow rate TC Rainfall Intensity No. (CFS) (min) (In/Hr) 1 2064.310 17.42 2.835 2 707.340 18.63 2.723 Qmax (1) = 1.000 * 1.000 * 2064.310) + „ 1.046 * 0.935 * 707.340) + = 2755.934 Qmax (2 ) = 0.960 * 1.000 * 2064.310) + 1.000 * 1.000 * 707.340) + = 2689.583 i q% AV A AN 46 10 42 A a 40 m change Suite CA -9260 JOB No, o 50 S BY DATE Soo- SHT. 544 q fit. OF ♦ LAND PLANNING CIVIL ENGINEERING ♦ SURVEYING HYDRAULICS FROM :HALLBFOREMAN,INC—TEMECULA FAX NO. :951-699-0896 Sep. 22 2004 12:26PM P6 �N-r,4 m ✓N4433q AliN JuauP�t�. 14-'K q' iQcg wIo&r p+� n�2.Ndo '� W a� wn1qs7 a '. . iz JuQuPA �M DG^TE'L1Ti 0i C4 a 4 Odd 1,47 1 r. vv I 1'r ds 1 I v- M � V �iaaK 7/0 '!FS �,44ey deTe.40k) loo r 1, 033 GFS Ql..- 179 e.Fg A-, 407. So Qt. a a='SC8. 73ae 14r 74.70 0,C c 2a. 7 l/.'99 J,= 2o.9 8 9 r. o. 04 wt o 189 >r� a se5�rr.3 se5�y6 7-4 a1 -a25 oti. lat, 0,'120 va, 0 DECLEZC 14ol HANNEL Tl FONTANA / DECLEZ CHANNEL W/ DET. AT SIERRE (AMC3) 0 0 T2 100 YEAR STORM T3 JN 04339 SO 23300.0001002.670 1 1002.670 R 24100.0001005.070 1 .014 .000 .000 0 JX 24100.0101005.070 1 2 .014 699.000 1005.070 .0 .000 R 24242.1201005.500 1 .014 .000 WX 24242.1201005.500 3 R 24242.1301005.500 3 .013 .000 .000 0 SH 24242.1301005.500 3 1005.500 CD 1 2 0 .000 11.000 24.000 .000 .000 .00 CD 2 4 1 .000 9.000 .000 .000 .000 .00 CD 3 3 0 .000 9.000 14.000 .000 .000 .00 Q 2064.000 .0 W A 14r�2 k A a A & i It A k A i A ! A a A a i b A i i &! t i & i lk i ■ 1 k i i I ! i FILE: DECLEZOCH.WSW W S P G W - EDIT LISTING - Version 12.9 Date: 9-22-2004 Time: 1:46: 2 WATER SURFACE PROFILE - CHANNEL DEFINITION LISTING PAGE 1 CARD SECT CHN NO OF AVE PIER HEIGHT 1 BASE ZL ZR INV Y(1) Y(2) Y(3) Y(4) Y(5) Y(6) Y(7) Y(8) Y(9) Y(10) CODE NO TYPE PIER/PIP WIDTH DIAMETER WIDTH DROP CD 1 2 0 .000 11.000 24.000 .00 CD 2 4 1 9.000 CD 3 3 0 .000 9.000 14.000 .000 .000 .00 W S P G W PAGE NO 1 WATER SURFACE PROFILE - TITLE CARD LISTING HEADING LINE NO 1 IS - FONTANA / DECLEZ CHANNEL W/ DET. AT SIERRE (AMC3) 0 HEADING LINE NO 2 IS - 100 YEAR STORM HEADING LINE NO 3 IS - JN 04339 W S P G W PAGE NO 2 WATER SURFACE PROFILE - ELEMENT CARD LISTING ELEMENT NO 1 IS A SYSTEM OUTLET U/S DATA STATION INVERT SECT W S ELEV 23300.000 1002.670 1 1002.670 ELEMENT NO 2 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 24100.000 1005.070 1 .014 .000 .000 .000 0 ELEMENT NO 3 IS A JUNCTION U/S DATA STATION INVERT SECT LAT -1 LAT -2 N Q3 Q4 INVERT -3 INVERT -4 PHI 3 PHI 4 24100.010 1005.070 1 2 0 .014 699.000 .000 1005.070 .000 .000 .000 RADIUS ANGLE .000 .000 THE ABOVE ELEMENT CONTAINED AN INVERT ELEV WHICH WAS NOT GREATER THAN THE PREVIOUS INVERT ELEV -WARNING THE ABOVE ELEMENT CONTAINED AN INVERT ELEV WHICH WAS NOT GREATER THAN THE PREVIOUS INVERT ELEV -WARNING ELEMENT NO 4 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 24242.120 1005.500 1 .014 .000 .000 .000 0 ELEMENT NO 5 IS A WALL EXIT U/S DATA STATION INVERT SECT 24242.120 1005.500 3 ELEMENT NO 6 IS A REACH U/S DATA STATION INVERT SECT RADIUS ANGLE ANG PT MAN H 24242.130 1005.500 3 .013 .000 .000 .000 0 ELEMENT NO 7 IS A SYSTEM HEADWORKS U/S DATA STATION INVERT SECT W S ELEV 24242.130 1005.500 3 1005.500 4:- k i a i 1 a i i t h A i► f f► i ■ A a 1 i I 1t l k i i I 1 & l t 1 k 1 k i ❑ FILE: DECLEZOCH.WSW W S P G W - CIVILDESIGN Version 12.9 PAGE 1 For: Lohr + Associates, Inc., Temecula, CA - S/N 773 WATER SURFACE PROFILE LISTING Date: 9-22-2004 Time: 1:45:39 FONTANA / DECLEZ CHANNEL W/ DET. AT SIERRE (AMC3) 0 100 YEAR STORM JN 04339 I Invert I Depth I Water I Q I Vel Vel I Energy I Super ICriticallFlow ToplHeight/IBase Wtl INo Wth Station I Elev I (FT) I Elev I (CFS) I (FPS) Head I Grd.E1.1 Elev I Depth I Width IDia.-FTIor I.D.I ZL IPrs/Pip -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I L/Elem ICh Slope I I I I SF Avel HF ISE DpthlFroude NINorm Dp I "N" I X -Fall) ZR (Type Ch I I I I I I I I I I I I I 23300.000 1002.670 7.246 1009.916 2763.00 15.89 3.92 1013.84 .00 7.44 24.00 11.000 24.000 .00 0 .0 -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- 1- 727.668 .0030 .0030 2.18 7.25 1.04 7.25 .014 .00 .00 RECTANG I I I I I I I I I I I I I 24027.670 1004.853 7.246 1012.099 2763.00 15.89 3.92 1016.02 .00 7.44 24.00 11.000 24.000 .00 0 .0 -i- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- 1- 72.332 .0030 .0029 .21 7.25 1.04 7.25 .014 .00 .00 RECTANG I I I I I I I I I I I I I 24100.000 1005.070 7.440 1012.510 2763.00 15.47 3.72 1016.23 .00 7.44 24.00 11.000 24.000 .00 0 .0 -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- I- JUNCT.STR .0000 .0017 .00 7.44 1.00 .014 .00 .00 RECTANG I I I I I I I I I I I I I 24100.010 1005.070 10.000 1015.070 2064.00 8.60 1.15 1016.22 .00 6.12 24.00 11.000 24.000 .00 0 .0 -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- 1- 142.109 .0030 .0007 .10 10.00 .48 5.89 .014 .00 .00 RECTANG I I I I I I I I I I I I I 24242.120 1005.500 9.567 1015.067 2064.00 8.99 1.25 1016.32 .00 6.12 24.00 11.000 24.000 .00 0 .0 WALL EXIT I I I I I I I I I I I I I 24242.120 1005.500 9.568 1015.068 2064.00 16.38 4.17 1019.23 .00 8.77 14.00 9.000 14.000 .00 0 .0 -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- 1- .012 .0000 .0054 .00 9.57 .96 .00 .013 .00 .00 BOX I I i I I I I I I I I I I 24242.130 1005.500 9.568 1015.068 2064.00 16.38 4.17 1019.23 .00 8.77 14.00 9.000 14.000 .00 0 .0 -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- I- 0 44 DECLEZ C dam R 0 N F E E e F E 8 HA A (/VEL R..E V15ED Tl FONTANA / DECLEZ CHANNEL W/ DET. AT SIERRE (AMC3) (REVISED) 0 T2 100 YEAR STORM T3 JN 04339 SO 23300.0001002.670 1 1002.670 R 24100.0001005.070 1 .014 .000 0 JX 24100.0101005.070 1 2 .014 692.000 1005.070 .000 R 24242.1201005.500 1 .014 WX 24242.1201005.500 3 R 24242.1301005.500 3 .013 .000 0 SH 24242.1301005.500 3 1005.500 CD 1 2 0 .000 11.000 24.000 .000 .000 .00 CD 2 4 1 .000 9.000 .000 .000 .000 .00 CD 3 3 0 .000 9.000 14.000 .000 .000 .00 Q 2064.000 .0 .000 .0 .000 .000 I 14-51 a A a i a i a i t i i i fi f a# a i I A ■ f lk f & i a i IL. A a I 1 i I i L i FILE: DECLEZOCH.WSW W S P G W - EDIT LISTING - Version 12.9 Date: 9-23-2004 Time: 5:11: 3 WATER SURFACE PROFILE - CHANNEL DEFINITION LISTING PAGE 1 CARD SECT CHN NO OF AVE PIER HEIGHT 1 BASE ZL ZR INV Y(1) Y(2) Y(3) Y(4) Y(5) Y(6) Y(7) Y(8) Y(9) Y(10) CODE NO TYPE PIER/PIP WIDTH DIAMETER WIDTH DROP CD 1 2 0 .000 11.000 24.000 .00 CD 2 4 1 9.000 CD 3 3 0 .000 9.000 14.000 .000 .000 .00 W S P G W PAGE NO 1 WATER SURFACE PROFILE - TITLE CARD LISTING HEADING LINE NO 1 IS - FONTANA / DECLEZ CHANNEL W/ DET. AT SIERRE (AMC3) (REVISED) HEADING LINE NO 2 IS - 100 YEAR STORM HEADING LINE NO 3 IS - JN 04339 W S P G W PAGE NO 2 WATER SURFACE PROFILE - ELEMENT CARD LISTING ELEMENT NO 1 IS A SYSTEM OUTLET U/S DATA STATION INVERT SECT W S ELEV 23300.000 1002.670 1 1002.670 ELEMENT NO 2 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 24100.000 1005.070 1 .014 .000 .000 .000 0 ELEMENT NO 3 IS A JUNCTION U/S DATA STATION INVERT SECT LAT -1 LAT -2 N Q3 Q4 INVERT -3 INVERT -4 PHI 3 PHI 4 24100.010 1005.070 1 2 0 .014 692.000 .000 1005.070 .000 .000 .000 RADIUS ANGLE .000 .000 THE ABOVE ELEMENT CONTAINED AN INVERT ELEV WHICH WAS NOT GREATER THAN THE PREVIOUS INVERT ELEV -WARNING THE ABOVE ELEMENT CONTAINED AN INVERT ELEV WHICH WAS NOT GREATER THAN THE PREVIOUS INVERT ELEV -WARNING ELEMENT NO 4 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 24242.120 1005.500 1 .014 .000 .000 .000 0 ELEMENT NO 5 IS A WALL EXIT U/S DATA STATION INVERT SECT 24242.120 1005.500 3 ELEMENT NO 6 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 24242.130 1005.500 3 .013 .000 .000 .000 0 ELEMENT NO 7 IS A SYSTEM HEADWORKS U/S DATA STATION INVERT SECT W S ELEV 24242.130 1005.500 3 1005.500 ❑ FILE: DECLEZOCH.WSW W S P G W - CIVILDESIGN Version 12.9 PAGE 1 For: Lohr + Associates, Inc., Temecula, CA - S/N 773 WATER SURFACE PROFILE LISTING Date: 9-23-2004 Time: 5:10:35 FONTANA / DECLEZ CHANNEL W/ DET. AT SIERRE (AMC3) (REVISED) 100 YEAR STORM JN 04339 *:t+****:tt**,t*�x*********t**t**+*,t,t*:t**+r,t****t*t*:t****,r***+++,r +:r :t t*** t:t:r r•***t,r*:r,t***,r rr,t,r*�+*,t+,t****t****:r*t��***+,t++*+*t* *�+,t+**t I Invert I Depth I Water I Q I Vel Vel I Energy I Super ICriticallFlow ToplHeight/IBase Wtl INo Wth Station I Elev I (FT) I Elev I (CFS) I (FPS) Head I Grd.E1.1 Elev I Depth I Width IDia.-FTlor I.D.1 ZL IPrs/Pip -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -1- -1 L/Elem ICh Slope I I I I SF Avel HF ISE DpthlFroude NINorm Dp I "N" I X -Fall) ZR (Type Ch I I I I i I I I I I I I I 23300.000 1002.670 7.233 1009.903 2756.00 15.88 3.91 1013.82 .00 7.43 24.00 11.000 24.000 .00 0 .0 -I- -I- -I- -I- -i- -I- -I- -I- -i- -I- -I- -I- -I- 1- 727.143 .0030 .0030 2.18 7.23 1.04 7.23 .014 .00 .00 RECTANG I I I I I 1 1 1 1 1 1 1 1 24027.140 1004.851 7.233 1012.084 2756.00 15.88 3.91 1016.00 .00 7.43 24.00 11.000 24.000 .00 0 .0 -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- 1- 72.857 .0030 .0029 .21 7.23 1.04 7.23 .014 .00 .00 RECTANG I I I I I 1 I I I I 1 I I 24100.000 1005.070 7.426 1012.496 2756.00 15.46 3.71 1016.21 .00 7.43 24.00 11.000 24.000 .00 0 .0 -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- I- JUNCT STIR .0000 .0017 .00 7.43 1.00 .014 .00 .00 RECTANG I I I 1 I I I I I I I I I 24100.010 1005.070 9.989 1015.059 2064.00 8.61 1.15 1016.21 .00 6.12 24.00 11.000 24.000 .00 0 .0 -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- 1- 142.109 .0030 .0007 .10 9.99 .48 5.89 .014 .00 .00 RECTANG I I I I I I I I I I I I I 24242.120 1005.500 9.556 1015.056 2064.00 9.00 1.26 1016.31 .00 6.12 24.00 11.000 24.000 .00 0 .0 WALL EXIT I I I I I I I I I I I I I 24242.120 1005.500 9.556 1015.056 2064.00 16.38 4.17 1019.22 .00 8.77 14.00 9.000 14.000 .00 0 .0 -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- 1- .012 .0000 .0054 .00 9.56 .96 .00 .013 .00 .00 BOX I I I I I I I I I I I I I 24242.130 1005.500 9.556 1015.056 2064.00 16.38 4.17 1019.22 .00 8.77 14.00 9.000 14.000 .00 0 .0 -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- I- 0 444 .r di m it 440 Ai ,m An ,. M. mm 10 me AN di Am �r dl 0 DZ 5 REVISED 3no 1301 * Tl FONTANA / TR 16678 LINE"DZ-5" (REVISED) 0 T2 100 YEAR STORM T3 JN 05086 SO 31.2201005.750 1 1015.060 R 67.9301005.820 1 .013 -46.741 .000 0 R 101.7401005.890 1 .013 .000 .000 0 ei R 164.4401006.020 1 .013 29.937 .000 0 ,e R 227.1401006.140 1 .013 -29.937 .000 0 TS 247.1401006.180 2 .013 .000 R 326.6101006.340 2 .013 .000 .000 0 JX 326.6201006.340 2 3 .013 12.000 1009.090 45.0 .000 R 417.9501006.520 2 .013 .000 .000 0 ,o R 489.3501006.670 2 .013 90.909 .000 0 R 494.3501006.680 2 .014 .000 .000 1 dr R 572.5401006.830 2 .013 .000 .000 0 *• R 656.3901007.000 2 .013 -40.035 .000 0 R 664.3701007.020 2 .013 -3.048 .000 0 TS 684.3701007.060 4 .013 -7.639 R 704.3701007.100 4 .013 -7.639 .000 0 TS 724.3701007.140 2 .013 -7.639 R 740.0001007.260 2 .013 -5.970 .000 0 JX 740.0101007.260 2 5 .013 31.000 1010.500 45.0 .000 R 788.0301007.650 2 .013 -18.342 ar .000 0 JX 793.0301008.690 10 .014 aA R 2070.0001020.440 10 .013 .000 .000 0 JX 2075.0001020.480 10 7 .014 42.000 1023.200 45.0 .000 *' R 3350.0001032.210 10 .013 .000 .000 0 JX 3355.0001032.760 6 8 .014 212.000 1033.730 .0 .000 ' R 3426.0001033.100 6 .013 90.400 .000 0 R 4685.0001039.140 6 .013 .000 0 � SH 4685.0001039.140 6 1039.140 ar CD.000 1 3 0 .000 7.000 12.000 .000 .000 .00 CD 2 4 1 .000 8.500 .000 .000 .000 .00 CD 3 4 1 .000 1.500 .000 .000 .000 .00 CD 4 3 0 .000 5.500 9.000 .000 .000 .00 CD 5 4 1 .000 2.000 .000 .000 .000 .00 CD 6 4 1 .000 7.000 .000 .000 .000 .00 1301 .. r di me Ad An id 40 4d .. do 49 no d A i1 0 CD 7 4 1 .000 2.500 CD 8 4 1 .000 5.000 CD 10 4 1 .000 7.500 Q 410.000 .0 .000 .000 .000 .00 .000 .000 .000 .00 .000 .000 .000 .00 f 3�� h A a A a i iE i a A h i I i t o r i a 1 i i A l a 1 6. ! k i k i & 1 L i a! FILE: 678DZ5R.WSW W S P G W - EDIT LISTING - Version 12.9 Date: 9-23-2004 Time: 9: 2:13 WATER SURFACE PROFILE - CHANNEL DEFINITION LISTING PAGE 1 CARD SECT CHN NO OF AVE PIER HEIGHT 1 BASE ZL ZR INV Y(1) Y(2) Y(3) Y(4) Y(5) Y(6) Y(7) Y(8) Y(9) Y(10) CODE NO TYPE PIER/PIP WIDTH DIAMETER WIDTH DROP CD 1 3 0 .000 7.000 12.000 .000 .000 .00 CD 2 4 1 8.500 CD 3 4 1 1.500 CD 4 3 0 .000 5.500 9.000 .000 .000 .00 CD 5 4 1 2.000 CD 6 4 1 7.000 CD 7 4 1 2.500 CD 8 4 1 5.000 CD 10 4 1 7.500 W S P G W PAGE NO 1 WATER SURFACE PROFILE - TITLE CARD LISTING HEADING LINE NO 1 IS - FONTANA / TR 16678 LINE"DZ-5" (REVISED) HEADING LINE NO 2 IS - 100 YEAR STORM HEADING LINE NO 3 IS - JN 05086 W S P G W PAGE NO 2 WATER SURFACE PROFILE - ELEMENT CARD LISTING ELEMENT NO 1 IS A SYSTEM OUTLET U/S DATA STATION INVERT SECT W S ELEV 31.220 1005.750 1 1015.060 ELEMENT NO 2 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 67.930 1005.820 1 .013 45.000 -46.741 .000 0 ELEMENT NO 3 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 101.740 1005.890 1 .013 .000 .000 .000 0 ELEMENT NO 4 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 164.440 1006.020 1 .013 120.000 29.937 .000 0 ELEMENT NO 5 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 227.140 1006.140 1 .013 120.000 -29.937 .000 0 ELEMENT NO 6 IS A TRANSITION U/S DATA STATION INVERT SECT N RADIUS ANGLE 247.140 1006.180 2 .013 .000 .000 ELEMENT NO 7 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 326.610 1006.340 2 .013 .000 .000 .000 0 ELEMENT NO 8 IS A JUNCTION U/S DATA STATION INVERT SECT LAT -1 LAT -2 N Q3 Q4 INVERT -3 INVERT -4 PHI 3 PHI 4 326.620 1006.340 2 3 0 .013 12.000 .000 1009.090 .000 45.000 .000 RADIUS ANGLE .000 .000 THE ABOVE ELEMENT CONTAINED AN INVERT ELEV WHICH WAS NOT GREATER THAN THE PREVIOUS INVERT ELEV -WARNING THE ABOVE ELEMENT CONTAINED AN INVERT ELEV WHICH WAS NOT GREATER THAN THE PREVIOUS INVERT ELEV -WARNING ELEMENT NO 9 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H i i i i a JI a i ! i h/ a i I l ■ i i i t i l i t i E I a A a A t l 1 i i i 417.950 1006.520 2 .013 .000 .000 .000 0 ELEMENT NO 10 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 489.350 1006.670 2 .013 45.000 90.909 .000 0 ELEMENT NO 11 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 494.350 1006.680 2 .014 .000 .000 .000 1 W S P G W PAGE NO 3 WATER SURFACE PROFILE - ELEMENT CARD LISTING ELEMENT NO 12 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 572.540 1006.830 2 .013 .000 .000 .000 0 ELEMENT NO 13 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 656.390 1007.000 2 .013 120.001 -40.035 .000 0 ELEMENT NO 14 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 664.370 1007.020 2 .013 150.006 -3.048 .000 0 ELEMENT NO 15 IS A TRANSITION U/S DATA STATION INVERT SECT N RADIUS ANGLE 684.370 1007.060 4 .013 150.009 -7.639 ELEMENT NO 16 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 704.370 1007.100 4 .013 150.009 -7.639 .000 0 ELEMENT NO 17 IS A TRANSITION U/S DATA STATION INVERT SECT N RADIUS ANGLE 724.370 1007.140 2 .013 150.009 -7.639 ELEMENT NO 18 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 740.000 1007.260 2 .013 150.006 -5.970 .000 0 ELEMENT NO 19 IS A JUNCTION U/S DATA STATION INVERT SECT LAT -1 LAT -2 N Q3 Q4 INVERT -3 INVERT -4 PHI 3 PHI 4 740.010 1007.260 2 5 0 .013 31.000 .000 1010.500 .000 45.000 .000 RADIUS ANGLE .000 .000 THE ABOVE ELEMENT CONTAINED AN INVERT ELEV WHICH WAS NOT GREATER THAN THE PREVIOUS INVERT ELEV -WARNING THE ABOVE ELEMENT CONTAINED AN INVERT ELEV WHICH WAS NOT GREATER THAN THE PREVIOUS INVERT ELEV -WARNING ELEMENT NO 20 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 788.030 1007.650 2 .013 150.002 -18.342 .000 0 ELEMENT NO 21 IS A JUNCTION U/S DATA STATION INVERT SECT LAT -1 LAT -2 N Q3 Q4 INVERT -3 INVERT -4 PHI 3 PHI 4 793.030 1008.690 10 0 0 .014 .000 .000 .000 .000 .000 .000 RADIUS ANGLE .000 .000 W S P G W PAGE NO 4 WATER SURFACE PROFILE - ELEMENT CARD LISTING ELEMENT NO 22 IS A REACH U/S DATA STATION INVERT SECT N RADIUS ANGLE ANG PT MAN H 2070.000 1020.440 10 .013 .000 .000 .000 0 ELEMENT NO 23 IS A JUNCTION U/S DATA STATION INVERT SECT LAT -1 LAT -2 N Q3 Q4 INVERT -3 INVERT -4 PHI 3 PHI 4 2075.000 1020.480 10 7 0 .014 42.000 .000 1023.200 .000 45.000 .000 RADIUS ANGLE i i i i I. A i i ! A i A & I t i k 1 ! A i A I A lk J & A lk A t i i I i I 1 i ELEMENT NO 24 IS A REACH U/S DATA STATION INVERT SECT N 3350.000 1032.210 10 .013 ELEMENT NO 25 IS A JUNCTION U/S DATA STATION INVERT SECT LAT -1 LAT -2 N Q3 3355.000 1032.760 6 8 0 .014 212.000 ELEMENT NO 26 IS A REACH U/S DATA STATION INVERT SECT N 3426.000 1033.100 6 .013 ELEMENT NO 27 IS A REACH U/S DATA STATION INVERT SECT N 4685.000 1039.140 6 .013 ELEMENT NO 28 IS A SYSTEM HEADWORKS U/S DATA STATION INVERT SECT 4685.000 1039.140 6 .000 .000 RADIUS ANGLE ANG PT MAN H .000 .000 .000 0 * * Q4 INVERT -3 INVERT -4 PHI 3 PHI 4 .000 1033.730 .000 .000 .000 RADIUS ANGLE .000 .000 RADIUS ANGLE ANG PT MAN H 45.000 90.400 .000 0 RADIUS ANGLE ANG PT MAN H .000 .000 .000 0 W S ELEV 1039.140 W U (,fI a A a A k i ! i a A i t a l M A a j & l r A a i & i I A & i IL i i I t 1 I I ❑ FILE: 678DZ5R.WSW W S P G W - CIVILDESIGN Version 12.9 PAGE 1 For: Lohr + Associates, Inc., Temecula, CA - SIN 773 WATER SURFACE PROFILE LISTING Date: 9-23-2004 Time: 8:58:51 FONTANA / TR 16678 LINE"DZ-5" (REVISED) 100 YEAR STORM JN 05086 I Invert I Depth I Water I 4 I Vel Vel I Energy I Super ICriticallFlow Top]Height/lBaSe Wt1 INo Wth Station I Elev I (FT) I Elev I (CFS) I (FPS) Head I Grd.El.l Elev I Depth I -I- Width IDia.-FTIor -I- -I- I.D.I -I- ZL ]Prs/Pip -I -I- L/Elem -I- ICh Slope I -I- -I- -I- I I I -I- -I- SF Avel -I- HF ISE -I- DpthlFroude N]Norm Dp I "N" I X -Fall] ZR IType Ch •**+*****I**��*****Ire******I*+*+*****I******,r**I*�*.***I+***c**I**r***�**I***r***Ir**+++�*Ir****+*+I*****.r1+�.****]***** I I I I I****.** I 31.220 I I 1005.750 I I I 9.310 1015.060 707.00 8.42 I 1.10 I 1016.16 .00 I 4.76 -I- 12.00 7.000 -I- -I- 12.000 .00 0 .0 -I- 36.710 -I- .0019 -I- -I- -I- -I- -I- .0019 -I- .07 -I- .00 .56 I 5.75 .013 -I- .00 .00 1- BOX 67.930 I I 1005.820 I I I 9.468 1015.288 707.00 8.42 I 1.10 I 1016.39 .00 I 4.76 -I- 12.00 I 7.000 -I- -I- I I 12.000 -I- .00 I 0 .0 -I- 33.810 -I- .0021 -I- -I- -I- -I- -I- .0019 -I- .06 -I- 9.47 .56 5.58 .013 .00 .00 1- BOX 101.740 I I 1005.890 I I I 9.461 1015.351 707.00 8.42 I 1.10 I 1016.45 .00 I I 4.76 -I- 12.00 I 7.000 -I- -I- I I 12.000 -I- .00 I 0 .0 -I- 62.7.00 -I- .0021 -I- -I- -I- -I- -I- .0019 -I- .12 -I- .00 .56 I 5.58 .013 .00 I I .00 1- BOX I 164.440 I I 1006.020 I I I 9.576 1015.596 707.00 8.42 I 1.10 I 1016.70 .00 I 4.76 -I- 12.00 I 7.000 -I- -I- 12.000 -I- .00 0 .0 1- -I- 62.700 -I- .0019 -I- -I- -I- -I- -I- .0019 -I- .12 -I- .00 .56 5.75 .013 .00 .00 BOX 227.140 I I 1006.140 I I I 9.701 1015.841 707.00 8.42 I 1.10 I 1016.94 .00 I I 4.76 12.00 I 7.000 I I 12.000 .00 I 0 .0 TRANS STR .0020 .0031 .06 9.70 .56 .013 .00 .00 BOX 247.140 I I 1006.180 I I I 8.675 1014.855 707.00 12.46 I 2.41 I 1017.27 .00 I I 6.66 -I- .00 I 8.500 -I- -I- I I .000 -I- .00 I 1 .0 -I- 79.470 -I- .0020 -I- -I- -I- -I- -I- .0043 -I- .35 -I- 8.68 .00 8.50 .013 .00 .00 1- PIPE 326.610 I I 1006.340 I I I 8.861 1015.201 707.00 12.46 I 2.41 I 1017.61 .00 I I 6.66 -I- .00 I 8.500 -I- -I- I I .000 -I- .00 I 1 .0 -I- JUNCT STR -I- .0000 -I- -I- -I- -I- -I- .0043 -I- .00 -I- 8.86 .00 .013 .00 .00 I- PIPE 326.620 I I 1006.340 I I I 8.991 1015.332 695.00 12.25 I 2.33 I 1017.66 .00 I I 6.61 -I- .00 I 8.500 -I- -I- I I .000 -I- .00 I 1 .0 -I- 91.330 -I- .0020 -I- -I- -I- -I- -I- .0042 -I- .38 -I- 8.99 .00 8.50 .013 .00 .00 1- PIPE 417.950 i I 1006.520 I I I 9.195 1015.715 695.00 12.25 I 2.33 I 1018.04 .00 I I 6.61 -I- .00 I 8.500 I I .000 .00 I 1 .0 -I- 71.400 -I- .0021 -I- -I- -I- -I- -I- .0042 -I- .30 -I- .00 .00 8.50 -I- -I- .013 -I- .00 .00 1- PIPE 1� FILE: 678DZ5R.WSW W S P G W - CIVILDESIGN Version 12.9 PAGE 2 For: Lohr + Associates, Inc., Temecula, CA - SIN 773 WATER SURFACE PROFILE LISTING Date: 9-23-2004 Time: 8:58:51 FONTANA / TR 16678 LINE"DZ-5" (REVISED) 100 YEAR STORM JN 05086 L! & i i A A. i 11 6, A IR l & l & i I i h i I A i 1 i I II 1 &, A I J I I i 1 I Invert I Depth I Water I Q I Vel Vel I Energy I Super ICriticallFlow ToplHeight/IBase Wtl INo Wth Station I Elev I (FT) I Elev -I- I (CFS) I -I- (FPS) -I- Head I -I- Grd.El.l -I- Elev -I- I Depth I -I- Width -I- IDia.-FTIor -I- I.D.I -I- ZL IPrs/Pip -I -i- L/Elem -i- ICh Slope I -I- I I I SF Avel HF ISE DpthlFroude NINorm Dp I "N" I X -Fall) ZR (Type Ch 489.350 I I 1006.670 I 9.814 1016.484 I I 695.00 12.25 I 2.33 1018.81 I .00 I I 6.61 .00 -I- I I 8.500 -I- I .000 -I- .00 I 1 .0 -I- 5.000 -I- .0020 -I- -I- -I- -I- -I- .0049 -I- .02 -I- 9.81 -I- .00 8.50 .014 .00 .00 1- PIPE 494.350 I I 1006.680 I 9.944 1016.624 I I 695.00 12.25 I 2.33 1018.95 I .00 I I 6.61 .00 I I 8.500 -I- I .000 -I- .00 I 1 .0 -I- 78.190 -I- .0019 -I- -I- -I- -1- -I- .0042 -I- .33 -I- 9.94 -I- .00 -I- 8.50 .013 .00 .00 1- PIPE 572.540 I I 1006.830 I 10.123 1016.953 I I 695.00 12.25 I 2.33 1019.28 I .00 I I 6.61 -I- .00 I I 8.500 -I- I .000 .00 I 1 .0 -I- 83.850 -I- .0020 -I- -I- -I- -I- -I- .0042 -I- .35 -I- .00 .00 -I- 8.50 .013 -I- .00 .00 1- PIPE 656.390 I I 1007.000 I 10.616 1017.616 I I 695.00 12.25 I 2.33 1019.95 I .00 I I 6.61 .00 I I 8.500 I .000 -I- .00 I 1 .0 -I- 7.980 -I- .0025 -I- -I- -I- -1- -I- .0042 -I- .03 -I- .00 -I- .00 -I- 8.50 -I- .013 .00 .00 1- PIPE 664..370 I I 1007.020 I 10.715 1017.735 I I 695.00 12.25 I 2.33 1020.06 I .00 I I 6.61 .00 I I 8.500 I .000 .00 I 1 .0 TRANS STR .0020 .0042 .08 .00 .00 .013 .00 .00 PIPE 684.370 I I 1007.060 I 10.206 1017.266 I I 695.00 14.04 I 3.06 1020.33 I .00 I I 5.50 9.00 I I 5.500 I 9.000 .00 I 0 .0 -I- 20.000 -I- .0020 -I- -I- -I- -I- -I- .0074 -I- .15 -I- .00 -I- 1.06 -I- 5.50 -I- .013 -I- .00 .00 1- BOX 704.370 I I 1007.100 I 10.492 1017.592 I I 695.00 14.04 I 3.06 1020.65 I .00 I I 5.50 9.00 I I 5.500 I 9.000 .00 I 0 .0 TRANS SIR .0020 .0058 .12 .00 1.06 .013 .00 .00 BOX 724.370 I I 1007.140 I 11.373 1018.513 I I 695.00 12.25 I 2.33 1020.84 I .00 I I 6.61 .00 I I 8.500 I .000 .00 I 1 .0 -I- 15.630 -I- .0077 -I- -I- -I- -I- -I- .0042 -I- .07 -I- .00 -I- .00 -I- 5.44 -I- .013 -I- .00 .00 1- PIPE 740.000 I I 1007.260 I 11.439 1018.699 I I 695.00 12.25 I 2.33 1021.03 I .00 I I 6.61 .00 I I 8.500 I .000 -I- .00 I 1 .0 -I- JUNCT STR -I- .0000 -I- -I- -I- -I- -I- .0040 -I- .00 -I- .00 -I- .00 -I- -I- .013 .00 .00 I- PIPE f] FILE: 678DZ5R.WSW W S P G W - CIVILDESIGN Version 12.9 PAGE 3 For: Lohr + Associates, Inc., Temecula, CA - S/N 773 WATER SURFACE PROFILE LISTING Date: 9-23-2004 Time: 8:58:51 FONTANA / TR 16678 LINE"DZ-5" (REVISED) 100 YEAR STORM JN 05086 *+*+**�**,r+rt*x*�****+tr******t**t,t***t:t***,tx,t*,r**,r*,tr,r+,t;tt***:tt*****t**;rx:r:r*�***,r:r:t***■**t*****w*:r*�**�*****+*:t*t:r***t*:t** x:r:t*+:t:tx I Invert I Depth I Water I Q I Vel Vel I Energy I Super ICriticallFlow ToplHeight/IBase Wtl INo Wth Station I Elev I (FT) I Elev I (CFS) I (FPS) Head I Grd.El.l Elev -I- I Depth I -I- Width IDia.-FTIor I.D.I -I- ZL -I IPrs/Pip -I- L/Elem -I- ICh Slope I -I- -I- I -I- I I -I- -I- SF Avel -I- HF ISE DpthlFroude NINorm -I- Dp -I- I SIN" I X -Fall) ZR (Type Ch & i & III: r & i IIS l It i Il A t o & I Il 1 IE A Its A & 1 1k A 1k 1 t 1 1 1 1 1 1 I 740.010 I I 1007.260 I 11.727 I 1018.987 I 664.00 11.70 I 2.13 I 1021.11 I .00 6.47 I .00 I I 8.500 1 .000 .00 1 1 C -I- 48.020 -I- .0081 -I- -i- -I- -I- -I- .0038 -I- .18 -I- .00 -I- .00 -I- 5.18 -I- .013 -I- .00 .00 1- PIPE 788.030 I I 1007.650 I 11.713 I 1019.363 I 664.00 11.70 -I- I 2.13 I 1021.49 I .00 6.47 I .00 I I 8.500 I .000 .00 I 1 C -I- JUNCT STR -I- .2080 -I- -I- -I- -I- .0066 -I- .03 -I- 11.71 -I- .00 -I- -I- .014 -I- .00 .00 I- PIPE 793.030 I I 1008.690 I 9.346 I 1018.036 I 664.00 15.03 I 3.51 I 1021.54 I .00 6.55 I .00 I I 7.500 I .000 .00 I 1 .0 -I- 1070.517 -I- .0092 -I- -i- -I- -I- -I- .0074 -I- 7.97 -I- 9.35 -I- .00 -I- 5.57 -I- .013 -I- .00 .00 1- PIPE 1863.547 I I 1018.540 I 7.500 I 1026.040 -I- I 664.00 15.03 -I- I 3.51 -I- I 1029.55 -I- I .00 6.55 -1- I .00 I I 7.500 I .000 .00 I 1 .0 -I- 95.634 -I- .0092 -I- -I- .0070 .66 -I- 7.50 .00 -I- 5.57 -I- .013 -I- .00 .00 1- PIPE 1959.181 I I 1019.420 I 7.181 I 1026.601 I 664.00 15.25 I 3.61 I 1030.21 I .00 6.55 I 3.03 I I 7.500 I .000 .00 I 1 .0 HYDRAULIC JUMP 1959.181 I I 1019.420 I 5.918 I 1025.338 I 664.00 17.76 I 4.90 I 1030.23 I .00 6.55 I 6.12 I I 7.500 I .000 .00 I 1 .0 -I- 85.088 -I- .0092 -I- -I- -I- -I- -I- .0077 -I- .66 -I- 5.92 -I- 1.27 -I- 5.57 -I- .013 -I- .00 .00 1- PIPE 2044.269 -I- I I 1020.203 I 6.190 I 1026.393 I 664.00 17.03 I 4.50 I 1030.89 I .00 6.55 -I- I 5.70 I I 7.500 I .000 .00 I 1 .0 25.731 -I- .0092 -I- -I- -I- -I- -I- .0071 -I- .18 -I- 6.19 1.15 -I- 5.57 -I- .013 -I- .00 .00 1- PIPE 2070.000 I I 1020.440 I 6.546 I 1026.986 I 664.00 16.23 I 4.09 I 1031.08 I .00 6.55 I 5.00 I I 7.500 I .000 .00 I 1 .0 -I- JUNCT STR -I- .0080 -I- -I- -I- -I- -I- .0077 -I- .04 -I- 6.55 -I- 1.00 -I- -I- .014 -I- .00 .00 I- PIPE 2075.000 I I 1020.480 I 7.834 I 1028.314 i 622.00 14.08 I 3.08 I 1031.39 I .00 6.38 I .00 I I 7.500 I .000 .00 I 1 .0 -I- 115.794 -I- .0092 -I- -I- -I- -I- -I- .0066 -I- .76 -I- 7.83 -I- .00 -I- 5.29 -I- .013 -I- .00 .00 1- PIPE ❑ FILE: 678DZSR.WSW W S P G W - CIVILDESIGN Version 12.9 PAGE 4 For: Lohr + Associates, Inc., Temecula, CA - S/N 773 WATER SURFACE PROFILE LISTING Date: 9-23-2004 Time: 8:58:51 FONTANA / TR 16678 LINE"DZ-5" (REVISED) 100 YEAR STORM JN 05086 I Invert I Depth I Water I 4 I Vel Vel I Energy I Super ICriticallFlow ToplHeight/IBaSe Wtl INo Wth Station -I- I Elev I -1- (FT) 1 -I- Elev I -I- (CFS) I (FPS) -I- Head I -I- Grd.E1.1 Elev I Depth -I- I Width -I- 1Dia.-FTIor -I- I.D.1 -I- ZL 1Prs/Pip L/Elem ICh Slope I I I -I- I SF Avel -I- HF ISE -I- DpthlFroude NINorm Dp 1 "N" I X-Fa111 ZR -I (Type Ch *********1*******k*I**k*****1********k1*********I*k*****I*******I***k*****I***k***I********I********1******k1*******1***** 1******* 2190.794 -I- I I 1021.545 I 7.527 I 1029.072 I 622.00 14.08 I 3.08 I 1032.15 I .00 6.38 I .00 I I 7.500 I .000 .00 I 1 .0 HYDRAULIC -I- JUMP -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- -I- (- 2190.794 I I 1021.545 I 5.285 I 1026.830 I 622.00 18.69 I 5.43 I 1032.26 I .00 6.38 I 6.84 I I 7.500 1 .000 .00 1 1 .0 Qj 0 w I I I f i i h I a I o f a I a I It A k A & A a 1 ! i & 1 k/ & l E 11 t 1 t ! -I- 413.791 -I- .0092 -I- -I- -I- -I- -I- .0092 -I- 3.81 -I- 5.29 1,49 -I- 5.29 -I- -I- .013 -I- .00 .00 1- PIPE I 2604.585 I 1025.352 I 5.285 1030.637 I I 622.00 18.69 I 5.43 I 1036.06 .00 I 6.38 I 6.84 I 7.500 I I .000 .00 I 1 C -I- 521.974 -I- .0092 -I- -I- -I- -I- -I- .0088 -I- 4.57 -I- 5.29 1.49 -I- 5.29 -I- -I- .013 -I- .00 .00 1- PIPE I 3126.559 I 1030.154 I 5.498 1035.653 I I 622.00 17.92 I 4.99 I 1040.64 .00 I 6.38 I 6.63 -I- I 7.500 -I- -I- I I .000 -I- .00 I 1 C -I- 148.250 -I- .0092 -I- -I- -I- -I- -I- .0079 -I- 1.17 -I- 5.50 1.38 5.29 .013 .00 .00 1- PIPE I 3274.809 I 1031.518 I 5.760 1037.278 I I 622.00 17.09 I 4.53 I 1041.81 .00 I 6.38 I 6.33 -I- I 7.500 -I- -I- I I .000 -I- .00 I 1 C -I- 58.869 -I- .0092 -I- -I- -I- -I- -I- .0071 -I- .42 -I- 5.76 1.26 5.29 .013 .00 .00 1- PIPE I 3333.678 I 1032.060 I 6.049 1038.109 I I 622.00 16.29 I 4.12 I 1042.23 .00 I 6.38 I 5.92 -I- I 7.500 -I- -I- I I .000 -I- .00 I 1 C -I- 16.322 -I- .0092 -I- -I- -I- -I- -I- .0065 -I- .11 -I- 6.05 1.13 5.29 .013 .00 .00 1- PIPE 3350.000 I I 1032.210 I 6.380 1038.590 i I 622.00 15.53 I 3.75 I 1042.34 .00 I 6,38 I 5.35 -I- I 7.500 I I .000 .00 I 1 .0 -I- JUNCT STR -I- .1100 -I- -I- -I- -I- -I- .0060 -I- .03 -I- 7.27 1.00 -I- -I- .014 -I- .00 .00 I- PIPE 3355.000 I I 1032.760 I 8.235 1040.995 i I 410.00 10.65 I 1.76 I 1042.76 .00 I 5.33 I .00 I 7.000 I I .000 .00 I 1 .0 -I- 71.000 -I- .0048 -I- -I- -I- -I- -I- .0041 -I- .29 -I- .00 .00 -I- 5.33 -I- -I- .013 -I- .00 .00 1- PIPE 3426.000 I I 1033.100 I 8.541 1041.641 t I 410,00 10.65 I 1.76 I 1043.40 .00 I 5.33 I .00 I 7.000 I I .000 .00 I 1 .0 -I- 1259.000 -I- .0048 -I- -I- -I- -I- -I- .0041 -I- 5.19 -I- 8.54 .00 -I- 5.32 -I- -I- .013 -I- .00 .00 1- PIPE ❑ FILE: 678DZ5R.WSW W S P G W - CIVILDESIGN Version 12,9 PAGE 5 For: Lohr + Associates, Inc., Temecula, CA - SIN 773 WATER SURFACE PROFILE LISTING Date: 9-23-2004 Time: 8:58:51 FONTANA / TR 16678 LINE"DZ-5" (REVISED) 100 YEAR STORM JN 05086 I Invert I Depth I Water I C) I Vel Vel I Energy I Super ICriticallFlow ToplHeight/IBase Wtl INo Wth Station I Elev I (FT) I Elev I (CFS) I (FPS) Head I Grd.El.I Elev I Depth I Width IDia.-FTIor I.D.I ZL IPrs/Pip -I- L/Elem -I- ICh Slope I -I- -I- I -I- I I -I- -I- SF Avel -I- HF ISE -I- DpthlFroude -I- -I- NINorm Dp -I- I "N" I -I- X -Fall) ZR -I IType Ch .�*+**r�+I**r*****:tlt***t,r**I****+****Ia**+.*****I�*,r:r*��I,r****:r*I+*****,r,r*Ir**,r*,t*I*******,rI*x**r***I,r:r.:r*+*I**+rx**I*r*•* I+**r.** 4685.000 -I- I I 1039.140 I 7.686 1046.826 -I- I I 410.00 -I- 10.65 -I- I 1.76 -I- I 1048.59 -I- .00 -I- I 5.33 I .00 -I- -I- I I 7.000 -I- I .000 -I- .00 I 1 .0 -I- -I- I- -1ti N i C VICINITY MAP NTS A• . M 48 i _ LOT "E' TO BE DEDICATED. AS A LANDSCAPE EASEMENT (LSE) 1 N LINE OF SIGHT 3 (364') 5 10,217 S.F. PE=1054.8 10.046 S.F. =401 ms=s z 4ocn tf o PE -1055.6 4.1 a PEa1056.4 Ia73,o PROPOSED - to 61.2 10'. WE PE -1058.i' PE All --J LSE10T LOT (Typ-) LIMITED USE AREA - - T LINE OF. SIGHT yam..... LOT .Du TO BE DEDICATED AS A LANDSCAPE EASEMENT (LMD) i U1 a"V SIGHT (364') ULTIMATE R/W.,, TO BE DEDICATED TO THE CITY OF FONTANA:.FOR.' STREET AND UTILITY PURPOSES. ou TC 34. LIMITED USE AREA`. 055 �C EXISTING R/W LINE OF SIGHT. (364') l 4-1 o' , 055.2 3V�STORM . l0 44, o PER HASTER LOT "C" TO BE DEDICATED A LANDSCAPE EASEMENT INTERIM DETENTI ASI SD TO MAS PLAN POINT CONNECTION 10.13 is W STORM DRAIN PER MASTER PLAN Q =1K6 CFS Tc • 12x89 MIN. . AFFA- 57.60 Am 68' SO• i 80• a1' "1 o 48 i _ 1 N 2 3 4 N 5 10,217 S.F. PE=1054.8 10.046 S.F. =401 ms=s 10,063 -;- 11.1 tf o PE -1055.6 4.1 a TO BE DEDICATED TO THE CITY OF FONTANA:.FOR.' STREET AND UTILITY PURPOSES. ou TC 34. LIMITED USE AREA`. 055 �C EXISTING R/W LINE OF SIGHT. (364') l 4-1 o' , 055.2 3V�STORM . l0 44, o PER HASTER LOT "C" TO BE DEDICATED A LANDSCAPE EASEMENT INTERIM DETENTI ASI SD TO MAS PLAN POINT CONNECTION 10.13 is W STORM DRAIN PER MASTER PLAN Q =1K6 CFS Tc • 12x89 MIN. . AFFA- 57.60 Am 68' SO• eon 80• a1' "1 7.117 Ac. 1 N 2 3 4 N 5 10,217 S.F. PE=1054.8 10.046 S.F. 10.031 S.F: 10,063 -;- 11.1 PE -1055.6 4.1 a PEa1056.4 PE -1057.2 PE -1058.i' PE All --J dao : 7�.'i��F � ��: � =e� �l i✓� � Mi f=� (y � .. 6-7 1 b� PROPOSED 10' :WIDE LSE LOT 0,75 aa L7 X50 t��gd _l0 64.0 '-LINE OF SIGHT (362') LOT "A" TO BE DEDICATED AS A LANDSCAPE EASEMENT (LSE) kal LIMITED USE AREA 1� EXISTING R/W f .1) LIMITEDUSE AREA 000 r2 tee. ULTIMATE R/W , L=a�Bo- f 41.-. z .7 •- l0 58.3 `--LINE OF SIGHT (362') (f7 -- TO BE DEDICATED TO THE CITY 'OF. FONTANA FOR STREET AND UTILITY PURPOSES. LOT "B" .TO BE DEDICATED AS. A LANDSCAPE EASEMENT. (LSE) 31• STORM DRAIN PER MASTER PLAN 17.taj 4 toy. LEGEND r CFS WAR RMOFF r i F Tc=9 ffdn 100 YEARTME OF CONCEM'RATiON A-3.8 Ac T%BUTARY AREA (ACAS) 172 - NODE MAMR (RSBC) 934 - NODE FLOW UNE ELE=VATION a FLOW UNEP GRAPHIC SCALE - AREA NUMBER RSBC LIVE A� STREAM NO. 100 0 50 .100 200 300 AREA IA l SCALE t» _ 100' —2004 r l t Ess FIELD BOOK REF. PREPARED : FOR: DATE:.Ls �� Crouse/B�ers &soc�ates Inc.jos No. ixoln tAORk TENTATIVE TRACT MAP' En ineerin SuNe n Planning Construction Management BRISTLCONE INVESTMENTS LLC LOD No. 9 9* Yi9*, 9* 9 � ; oz 2191 5th St 011 Suite :200, Norco, Ca. 92860-1967 1125 E. MARIPOSA S T. N0,16678 DRAM BY Eq. 12-31-W Ph. (909) 736-2040 Fox (909) 736-5292 AL TA DENA, CA 91001 CITY OF FONTANA s C .. � -CALIFORNIA CHECKED BY �.-�. /Y1� PHONE. (626) 945— 913.7 �15ate Douglas N. rouse R.C.E. 23799 .. SHEET ._1_. OF Ex fires 12-31-05 MARK P . AT