STANDARD RETAINING WDETAIL VICINITY MAP
NTS
PART -III RETAINING WALL DETAILS
X
N
2" CLR.
-2-#4 BARS
2" CLR.
2" CLR.
1-#4 BAR-
D 24" O.C.
0" HEELI
POUR FOOTING AGAINST B
UNDISTURBED NATURAL
SOIL OR COMPACTED FILL
2-#4 BARS
T z
2 CLR.
1.5" KEY
Y BARSN
3" CLR. N
3-#4 BARS CONT.
TYPICAL SECTION OVER 5'-O"
0 TOE
PART -IV RETAINING WALL SCHEDULE
i
1-#4 BAR -
0. 24" O.C.
X
1
X
1
x
Q
2" CLR.
0
I
u7
Z
6"
N
N
2" CLR.
Q
PART -V RETAINING WALL DRAIN
SYSTEM DETAIL
RETAINING WALL -
APPROVED
WATER PROOFING
j�
�jfijj'yl:�l� •I'll'/lc
1 CU. FT./FT. OF 3/4" - 1.5
CLEAN GRAVEL WITH ;
A) 4" (MINIMIM) DIA. PERFORM
PVC PIPE (SCEDULE 40 OR
EQUIVALENT) WITH PERFORK
ORIENTED DOWN AS DEPICTS
1 % GRADIENT TO DRAIN
INTO UNDERWALK DRAIN.
B) OMIT HEAD JOINT IN FIRST
NATURAL SOIL OR
COMPACTED FILL
1.5" KIr
EY
X BARS
�3" CLR. N
2-#4
12" BARS CONT.
2„
0.B
TYPICAL SECTION 5'-0" MAX.
PART -VI MATERIAL SPECIFICATIONS
1. Cement shall conform to UBC STD No. 26-1; Concrete blocks shall conform to UBC STD No. 24-4 and ASTM 090;
Reinforcement shall conform to UBC STD No. 26-4 and ASTM A615 Grade 40, and shall be deformed; Aggregate shall
conform to UBC STD No. 24-23 for grout and UBC STD No. 26-2 for concrete; Water used in mixing concrete, mortar,
and grout, shall be clean and free from injurious amounts of oils, salts, organic maters or other substances that may
be deleterious to the concrete, mortar, grout or reinforcement.
2. Footing concrete shall be: fc 3250 PSI minimum at 28 days.
3. Grout shall conform to the requirements of UBC STD No. 24-29 and shall be; 1 part Cement to 3 parts Sand to 2 parts
Pea Gravel — maximum size 3/8", (fc = 2000 PSI).
4. Mortar shall conform to the requirements of UBC STD No. 24-20 and shall be; 1 part Cement to 1/4 part Lime to 3 parts
Sand.
ARS
GENERAL NOTES:
1 All materials shall be stored in a manner such that deterioration or intrusion of forei
n mater' Is r ent d d that
H
T
6" HEEL 0" TOE
X BARS
Y B
B K B K
BACKFILL SLOPE 1:2
4'
8"
2'-g"
17"
3'-0"
20"
#4@24"o. C.
5'
8"
3' —3)'
24"
3' —8"
27$0
#5@16"o. c.
6'
12"
S-8"
32"
4'-6"
36"
#4@24 O.C. #5024 O.C.
BACKFILL SLOPE 1: 3
4'
8"
2'-6"
14"
2'-10"
14"
#4024 O.C.
5'
8"
2'-9"
21"
3'-3"
20"
#5016"o.c.
6'
12"
3'-3"
27"
4'-0"
26"
#4@24"o.c. #5@24 O.C.
BACKFILL SLOPE 1:4
4'
8"
2'-3"
12"
2'-8"
10"
#4024"0. C.
5'
8"
21-9"
18"
3P-30$
15"
#4@16"o. c.
6
12"
3'-3"
24"
3'-10"
20"
#4024"o.c. #4024"o.c.
'OKFILL SLOPE 1:5
4'
8"
2'-3"
10"
2'-6"
8"
#4@24"o. C.
5'
8"
20-901
16"
3' - 0"
12"
#4@16"o. c.
69
12"
3'-3"
22"
3'-8"
18"
#4@24"o.c. #4@24"o. C.
'EL BACKFILL
41
8 t
2'-3"
8:f
20-6"
4"
#4@24"o. C.
5'
8"
2' - 9"
14"
3' - 0"
7"
#4016"0. C.
6'
12"
3'-3"
18"
S-6"
10"
#40241$o.c. #4024"o.c.
g �a is p ev a an
the material will be capable of meeting applicable requirements at the time of mixing. Masonry materials shall be stored
so that at the time of use the materials are clean and structurally suitable for the intended use. Concrete masonry units
shall not be wetted unless otherwise approved.
2. Reinforcement shall be placed prior to inspection and grouting, with vertical reinforcement located in the cell as
indicated in Part—III. All reinforcement shall be free from loose rust and other coatings that would inhibit reinforcing bond,
and shall be secured against displacement prior to the placement of concrete or grouting by wire positioners or other
suitable devices at intervals not exceeding 200 bar diameters nor 10 feet. Grout Stop shall be completely omitted at
all cells containing vertical reinforcement.
3. Footings shall be level. If ground slopes, footings shall be stepped so that the top and bottom of the footing are level. All
excavations shall be clean and contain no loose earth or other foreign materials.
4. The method of measuring material for mortar and grout shall be such that proportions of the materials can be controlled.
The mortar shall be sufficiently plastic and units shall be placed with sufficient pressure to extrude mortar from the joint
and produce a tight joint. Mortar or grout wich has hardened or stiffened due to hydration of the cement shall not be
used, but under no case shall mortar be used two and one—half hours(2-1\2 hrs), nor grout used one and one—half
hours(1-1 \2 hrs), after the initial mixing water has beed added to the dry ingredient at the job site.
5. The initial bed joint thickness shall not be less than 1/4 inch nor more than 1 inch; subsequent bed joints shall be not
less than 1/4 inch nor more than 5/8 inch in thickness. All head and bed joints shall be filled solidly with mortar for a
distance in from the face of the unit not less than the thickness of the shell, (if required, head joints may be omitted
in the first course for weep holes.)
6 Srf t bt t th rt t hll b l df f dlt t I
u aces o e in con ac wi mo ar or grou s a e c can an ree rom e e erious ma eria s.
7. Prior to grouting, the grout space shall have vertical continuity and shall be clean so that all spaces to be filled with grout
do not contain mortar projections greater than 1/2 inch, mortar droppings or other foreign material. All cells and spaces
containing reinforcing bars shall be filled solidly with grout.
8. If any portion of the wall is to extend across a property line, written (notarized) permision from the adjacent property
owner is required.
9. Building Department Inspection shall be following steps: PREPARE[
1st — foundation trench with secured reinforcing steel.
2nd — Block wall with reinforcing steel in place BEFORE GROUT.
3rd — Gouted wall and drainage system. (NO BACKFILL is allowed before drain system inspection
SEE NOTE #12). TEN
4th — Backfill and final.
10. 8" wide Slump Block and 4" or 6" wide Precision Block are not permitted. 7072
11. All works shall conform to the latest adopted edition of the UBC. H U NTI I
12. Provide retaining wall drainage system as shown on Part V. (714)
F,
8" I 12" I 4)_101$
NOTE TO CONTRACTOR:
REFER TO PROJECT'S LATEST SOILS REPORT AND ADDENDUMS
FOR BACKFILL AND DRAINAGE REQUIREMENTS.
2 x 8 x 16 CAP BLOCK IF DESIRED
8 x 8 x 16 CONC. BLOCK
STEM HORIZ. STEEL
#4 (TYP)
5.25"
8"
4" MIN
FOOTING LONG. STEEL
#4 (TYP)
3" CLEAR
(TYP)
0 0
(STU
1L
F
0'?'
`� • %�
GRATE \
INLET \\ /
00
3" SCH 40
PVC DRAIN
/-@) 200'+_ O.C.
#4 @ 24" 4
I �
N
8" I 122P I 6$_11P
NOTE TO CONTRACTOR:
REFER TO PROJECT'S LATEST SOILS REPORT AND ADDENDUMS
FOR BACKFILL AND DRAINAGE REQUIREMENTS.
LL
J W � W
� Q W Q
LL �
(n Q
m �
U >
EXISTING SOUTHRIDGE VARIES 0 �
THEMEWALL
VARIES PROPOSED
PAD RETAINING
WALL
NO 042723
EXP. 3131100
FCS.
3" SCH 40 4" CORE
PVC DRAIN 2' 8' @ OUTLET
@ 200'+_ O.C.
SECTION "A -A"
no Scale
D: \13RDWGS\FIESTA\13893\WP