HomeMy WebLinkAbout2647-1Q Q > LLJ w � 0 a SLOVER AVENUE 0 M UJ LAN TRACT N(D.13893 0C 14682 WALL = 4 9 _w JURUPA AVENUE UI (-,I = AVE o� L 60 !OR CypRfSS JUT"7"U P A AV ENUE WAGE--pROJECT SITE LIVE RIVERSIDE ROAD STAN INO C*. - ..LE OF FONTANA �__ __ __.� DE CO. STANDARD RETAINING WDETAIL VICINITY MAP NTS PART -III RETAINING WALL DETAILS X N 2" CLR. -2-#4 BARS 2" CLR. 2" CLR. 1-#4 BAR- D 24" O.C. 0" HEELI POUR FOOTING AGAINST B UNDISTURBED NATURAL SOIL OR COMPACTED FILL 2-#4 BARS T z 2 CLR. 1.5" KEY Y BARSN 3" CLR. N 3-#4 BARS CONT. TYPICAL SECTION OVER 5'-O" 0 TOE PART -IV RETAINING WALL SCHEDULE i 1-#4 BAR - 0. 24" O.C. X 1 X 1 x Q 2" CLR. 0 I u7 Z 6" N N 2" CLR. Q PART -V RETAINING WALL DRAIN SYSTEM DETAIL RETAINING WALL - APPROVED WATER PROOFING j� �jfijj'yl:�l� •I'll'/lc 1 CU. FT./FT. OF 3/4" - 1.5 CLEAN GRAVEL WITH ; A) 4" (MINIMIM) DIA. PERFORM PVC PIPE (SCEDULE 40 OR EQUIVALENT) WITH PERFORK ORIENTED DOWN AS DEPICTS 1 % GRADIENT TO DRAIN INTO UNDERWALK DRAIN. B) OMIT HEAD JOINT IN FIRST NATURAL SOIL OR COMPACTED FILL 1.5" KIr EY X BARS �3" CLR. N 2-#4 12" BARS CONT. 2„ 0.B TYPICAL SECTION 5'-0" MAX. PART -VI MATERIAL SPECIFICATIONS 1. Cement shall conform to UBC STD No. 26-1; Concrete blocks shall conform to UBC STD No. 24-4 and ASTM 090; Reinforcement shall conform to UBC STD No. 26-4 and ASTM A615 Grade 40, and shall be deformed; Aggregate shall conform to UBC STD No. 24-23 for grout and UBC STD No. 26-2 for concrete; Water used in mixing concrete, mortar, and grout, shall be clean and free from injurious amounts of oils, salts, organic maters or other substances that may be deleterious to the concrete, mortar, grout or reinforcement. 2. Footing concrete shall be: fc 3250 PSI minimum at 28 days. 3. Grout shall conform to the requirements of UBC STD No. 24-29 and shall be; 1 part Cement to 3 parts Sand to 2 parts Pea Gravel — maximum size 3/8", (fc = 2000 PSI). 4. Mortar shall conform to the requirements of UBC STD No. 24-20 and shall be; 1 part Cement to 1/4 part Lime to 3 parts Sand. ARS GENERAL NOTES: 1 All materials shall be stored in a manner such that deterioration or intrusion of forei n mater' Is r ent d d that H T 6" HEEL 0" TOE X BARS Y B B K B K BACKFILL SLOPE 1:2 4' 8" 2'-g" 17" 3'-0" 20" #4@24"o. C. 5' 8" 3' —3)' 24" 3' —8" 27$0 #5@16"o. c. 6' 12" S-8" 32" 4'-6" 36" #4@24 O.C. #5024 O.C. BACKFILL SLOPE 1: 3 4' 8" 2'-6" 14" 2'-10" 14" #4024 O.C. 5' 8" 2'-9" 21" 3'-3" 20" #5016"o.c. 6' 12" 3'-3" 27" 4'-0" 26" #4@24"o.c. #5@24 O.C. BACKFILL SLOPE 1:4 4' 8" 2'-3" 12" 2'-8" 10" #4024"0. C. 5' 8" 21-9" 18" 3P-30$ 15" #4@16"o. c. 6 12" 3'-3" 24" 3'-10" 20" #4024"o.c. #4024"o.c. 'OKFILL SLOPE 1:5 4' 8" 2'-3" 10" 2'-6" 8" #4@24"o. C. 5' 8" 20-901 16" 3' - 0" 12" #4@16"o. c. 69 12" 3'-3" 22" 3'-8" 18" #4@24"o.c. #4@24"o. C. 'EL BACKFILL 41 8 t 2'-3" 8:f 20-6" 4" #4@24"o. C. 5' 8" 2' - 9" 14" 3' - 0" 7" #4016"0. C. 6' 12" 3'-3" 18" S-6" 10" #40241$o.c. #4024"o.c. g �a is p ev a an the material will be capable of meeting applicable requirements at the time of mixing. Masonry materials shall be stored so that at the time of use the materials are clean and structurally suitable for the intended use. Concrete masonry units shall not be wetted unless otherwise approved. 2. Reinforcement shall be placed prior to inspection and grouting, with vertical reinforcement located in the cell as indicated in Part—III. All reinforcement shall be free from loose rust and other coatings that would inhibit reinforcing bond, and shall be secured against displacement prior to the placement of concrete or grouting by wire positioners or other suitable devices at intervals not exceeding 200 bar diameters nor 10 feet. Grout Stop shall be completely omitted at all cells containing vertical reinforcement. 3. Footings shall be level. If ground slopes, footings shall be stepped so that the top and bottom of the footing are level. All excavations shall be clean and contain no loose earth or other foreign materials. 4. The method of measuring material for mortar and grout shall be such that proportions of the materials can be controlled. The mortar shall be sufficiently plastic and units shall be placed with sufficient pressure to extrude mortar from the joint and produce a tight joint. Mortar or grout wich has hardened or stiffened due to hydration of the cement shall not be used, but under no case shall mortar be used two and one—half hours(2-1\2 hrs), nor grout used one and one—half hours(1-1 \2 hrs), after the initial mixing water has beed added to the dry ingredient at the job site. 5. The initial bed joint thickness shall not be less than 1/4 inch nor more than 1 inch; subsequent bed joints shall be not less than 1/4 inch nor more than 5/8 inch in thickness. All head and bed joints shall be filled solidly with mortar for a distance in from the face of the unit not less than the thickness of the shell, (if required, head joints may be omitted in the first course for weep holes.) 6 Srf t bt t th rt t hll b l df f dlt t I u aces o e in con ac wi mo ar or grou s a e c can an ree rom e e erious ma eria s. 7. Prior to grouting, the grout space shall have vertical continuity and shall be clean so that all spaces to be filled with grout do not contain mortar projections greater than 1/2 inch, mortar droppings or other foreign material. All cells and spaces containing reinforcing bars shall be filled solidly with grout. 8. If any portion of the wall is to extend across a property line, written (notarized) permision from the adjacent property owner is required. 9. Building Department Inspection shall be following steps: PREPARE[ 1st — foundation trench with secured reinforcing steel. 2nd — Block wall with reinforcing steel in place BEFORE GROUT. 3rd — Gouted wall and drainage system. (NO BACKFILL is allowed before drain system inspection SEE NOTE #12). TEN 4th — Backfill and final. 10. 8" wide Slump Block and 4" or 6" wide Precision Block are not permitted. 7072 11. All works shall conform to the latest adopted edition of the UBC. H U NTI I 12. Provide retaining wall drainage system as shown on Part V. (714) F, 8" I 12" I 4)_101$ NOTE TO CONTRACTOR: REFER TO PROJECT'S LATEST SOILS REPORT AND ADDENDUMS FOR BACKFILL AND DRAINAGE REQUIREMENTS. 2 x 8 x 16 CAP BLOCK IF DESIRED 8 x 8 x 16 CONC. BLOCK STEM HORIZ. STEEL #4 (TYP) 5.25" 8" 4" MIN FOOTING LONG. STEEL #4 (TYP) 3" CLEAR (TYP) 0 0 (STU 1L F 0'?' `� • %� GRATE \ INLET \\ / 00 3" SCH 40 PVC DRAIN /-@) 200'+_ O.C. #4 @ 24" 4 I � N 8" I 122P I 6$_11P NOTE TO CONTRACTOR: REFER TO PROJECT'S LATEST SOILS REPORT AND ADDENDUMS FOR BACKFILL AND DRAINAGE REQUIREMENTS. LL J W � W � Q W Q LL � (n Q m � U > EXISTING SOUTHRIDGE VARIES 0 � THEMEWALL VARIES PROPOSED PAD RETAINING WALL NO 042723 EXP. 3131100 FCS. 3" SCH 40 4" CORE PVC DRAIN 2' 8' @ OUTLET @ 200'+_ O.C. SECTION "A -A" no Scale D: \13RDWGS\FIESTA\13893\WP